My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:16:18 AM
Creation date
2/28/2020 11:57:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 1 of 1 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: f Tank Manufacturer Co Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r vacuum r Hydrostatic <br /> r Other (Specify) <br /> Test Equipment Used: i..gauge j Equipment Resolution: 0 loss <br /> Tank# 1 Tank# 2 Tank# 3 Tank# <br /> Is Tank Exempt From Testing?l r Yes r NO I r Yes r NO r Yes r NO r Yes r NO <br /> Tank Capacity: 10000 5000 20000 <br /> Tank Material: Fiberglass Fiberglass Fiberglass <br /> i <br /> Tank Manufacturer: Xerxes I xerxes xerxes <br /> Product Stored: PREMIUM Diesel REGULAR <br /> Wait time between applying <br /> pressure/vacuum/water and starting test: min min min min <br /> Test Start Time: <br /> Initial Reading(RI): <br /> i <br /> Test End Time: <br /> Final Reading(RF): I <br /> Test Duration: <br /> Change in Reading(RF-RI) <br /> I <br /> Pass/Fail Threshold or Criteria: +/- <br /> Test Result: <br /> Was sensor removed for testing? r Yes r Nor NA r Yes r No r NA r Yes r NO r NA r Yes r Nor NA 11 <br /> I <br /> Was sensor properly replaced and verified <br /> functional after testing? r Yes r Nor NA r Yes r Nor* NA r Yes r No r NA r Yes r No r NA i <br /> Comments ? (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> can't test annulars due to they are brine filled wet annulars <br /> ......-_._....._........._.._... ......_..............--------.._-._._...._.._...... <br /> 1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic <br /> containment testing. <br />