My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:16:18 AM
Creation date
2/28/2020 11:57:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 of 2 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: �' UDC Manufacturer r Industry Standard (? Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r Vacuum (' Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used: VPLT I Equipment Resolution: 0.00001 in. <br /> UDC#9/10 UDC #11/12 UDC # UDC aX <br /> UDC Manufacturer: unknown unknown <br /> LIDC Material: Fiberglass Fiberglass <br /> UDC Depth: 30.00 30.00 <br /> Height from UDC Bottom to Top of 15-00 15.00 <br /> Highest Piping Penetration: <br /> Height from UDC Bottom to Lowes[ <br /> Electrical Penetration: 3.00 32.00 <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested' 17 17 <br /> Does turbine shut down when UDC <br /> sensor detects liquid(troth product and r Yes r No G NA r Yes r No NA r Yes r No NA r Yes( Nor NA <br /> water)?- <br /> Turbine shutdown response time sec Sec SBC SEC <br /> Is system programmed for fall-safe r Yes r No f- NA r Yes r No I- NA r Yes r No r NA r Yes r No r NA <br /> shutdown?• <br /> Was fail-safe verified to be operational?* r Yes r No G NA r Yes r No(0— NA r Yes r No r NA r Yes r No NA <br /> Walt time between applying <br /> pressure/vacuum/water and starting test $ min 5 min min min <br /> Test start Time: 14:18:00 14;23;00 <br /> Initial Reading(Rl): 0.00000 In. H2O 0.00000 In. H2O <br /> Test End Time: 14:33:00 14:38:00 <br /> Final Reading(Rr): 0.00060 In. H2O -0.00020 in. H2O <br /> Test Du moon: 15 m i n 15 m i n <br /> Change in Reading(RF-RI): 0.00060 in. H2O -0.00020 in. H2O <br /> Pass/Fall Threshold or Criteria: +/-0.00200 +/-0.00200 +/- +/- <br /> Test Result: Pass Pass <br /> Was sensor removed for testing? Yes r No r NA fi Yes r No r NA r Yes r No NA r Yes r No r NA <br /> was ed sorfun poral ly after <br /> testing? <br /> and G Yes r No r NA t: Yes( Nor NA r Yes r No r NA r Yes r No NA <br /> verified functional after testing7 <br /> Comments ?(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> t If the entire depth of the UDC Is not tested,specify how much was tested. If the answer to any of the questions indicated with an asterisk(')is?NO?or?NA?,the <br /> entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.