My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REGEIVE__.�..' <br /> a61rrLER-RYAN INC. GR Job# 20-630774.1 <br /> SWRCB,January 2002 JUN 0 2 2015 Page 3 of 3 <br /> 7.UNDER-DISPENSER CONT"��WESTING <br /> Test Method Developed By: Tank Manufacturer Industry Standard Professional Engineer <br /> Other(specify) <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> Other(specify) <br /> Test Equipment Used: Incon Equipment Resolution: 0.0001 <br /> UDC# 7-8 UDC# UDC# UDC# 71 <br /> UDC Manufacturer: Environ <br /> UDC Material: Plastic <br /> UDC Depth: 33" <br /> Height from UDC Bottom to Top <br /> 13" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to Top <br /> 8" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Good <br /> testing: <br /> Portion of UDC Tested(1) Above Penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(bothNo NA Yes No NA Yes No NA Yes No NA <br /> product and water)?* <br /> Turbine shutdown response time 2sec <br /> Is system programmed for fail-safe <br /> shutdown?* <br /> es' No NA Yes No NA Yes No NA Yes No NA <br /> Was fail-safe verified to be yd No NA Yes No NA Yes No NA Yes No NA <br /> operational?* � # <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10min <br /> test: <br /> Test Start Time: 10:04am <br /> Initial Reading(Ri): 5,3930 <br /> Test End Time: 10:19am <br /> Final Reading(Rf) 5.3927 <br /> Test duration: 15miu <br /> Change in Reading(Rf-Ri): 0.0003 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Results: a Pass Fail Pass Fail Pass Fail Pass Fail <br /> Was sensor removed for testing? No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and �, I <br /> verified functional after testing? ' No NA Yes No NA Yes No NA Yes No NA <br /> Comments-(include information on repairs made prior to testing, and recommend follow-up for failed tests) <br /> (1)If the entire depth of the UDC is not tested,specify how much was tested. If the answer to a_y of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested.(See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.