2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0522688
PE
2950
FACILITY_ID
FA0015464
FACILITY_NAME
PIZZA HUT RESTAURANT
STREET_NUMBER
21
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
04305013
CURRENT_STATUS
01
SITE_LOCATION
21 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOR www.secor.com <br /> INTERNATIONAL Post Office Box 1508 <br /> S E C O R INCORPORATED 7730 Southwest Mohawk Street <br /> Tualatin,Oregon 97062 <br /> 503-691-2030 TEL <br /> 503-692-7074 FAx <br /> June 3, 2004 <br /> Ms. Mary Schulz <br /> GE Franchise Finance <br /> 17207 N. Perimeter Drive <br /> Scottsdale, AZ 85255-5402 <br /> RE: Proposal for Phase II Environmental Site Assessment <br /> Rick's #7 West <br /> Pizza Hut <br /> 21 W. Lodi Avenue <br /> Lodi, San Joaquin County, California 95240 <br /> SECOR Proposal No. 15g-04-149 <br /> Dear Ms. Schulz: <br /> SECOR International Incorporated (SECOR) has prepared this proposal to complete a Phase II <br /> Environmental Site Assessment (ESA) at the Pizza Hut located at 21 W. Lodi Avenue in Lodi, San <br /> Joaquin County, California (subject property). SECOR understands that this project is of the utmost <br /> importance and that a written report is required by June 24, 2004. SECOR previously prepared a <br /> Phase I ESA, dated May 12, 2004 for the subject property. Preliminary findings of the Phase I ESA <br /> identified the following recognized environmental conditions: <br /> • The subject property operated as a gasoline station from at least 1961 until 1974. The final <br /> disposition of the underground storage tanks (USTs) is unknown. The potential presence of <br /> USTs at the subject property, and the former storage and dispensing of petroleum products <br /> at the subject property, represents a recognized environmental condition. <br /> Based on these findings, GE Franchise Finance has requested that SECOR prepare this proposal <br /> for a Phase II ESA to further assess the potential for subsurface contamination. <br /> PROPOSED SCOPE OF WORK <br /> Based on SECOR's previous Phase I ESA, SECOR proposes to conduct a Phase II ESA, consisting <br /> of a geophysical survey to assess for the presence of USTs formerly operated at the subject <br /> property, and a limited subsurface investigation at the subject property to assess the possible <br /> presence of impacted soil and groundwater. Specific details of the proposed work are as follows: <br /> Task 1 - Preparation of Site <br /> Prior to initiating sampling activities, SECOR will contact the public utility locating service to request <br /> that locations of subsurface utilities at the proposed boring locations be marked. At least three days <br /> should be allowed to identify utilities and clear boring locations. <br /> In addition, SECOR will also obtain drilling permits from the County Health Department and work <br /> with property management to gain access for completion of the proposed work. At least one week <br /> will be required to obtain drilling permits. <br /> SECOR will also prepare a site-specific Health and Safety Plan (HASP) to address potential <br /> environmental and physical hazards associated with the proposed sampling. The HASP will be <br /> reviewed by SECOR field personnel and reviewed with SECOR subcontractors prior to initiating the <br /> geophysical survey and field sampling activities. The HASP will establish personnel protection <br /> standards and mandatory safety practices and procedures for use during the field investigation. A <br /> 15g-04-149-LodiPHll <br />
The URL can be used to link to this page
Your browser does not support the video tag.