My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1640
>
2200 - Hazardous Waste Program
>
PR0541222
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 1:44:45 PM
Creation date
3/2/2020 9:25:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0541222
PE
2229
FACILITY_ID
FA0014999
FACILITY_NAME
Global Materials Management, LLC
STREET_NUMBER
1640
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1640 N Broadway Ave
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telep< one: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Large Qua tity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Global Materials Management, L C 1640 N Broadway Ave, Stockton August 26, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 501 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks. <br /> SE-25 Oil filter Kruncher as seen storing hazardous waste (used oil) in the secondary containment. It was <br /> described by Mr. Kandathil the secondary containment was drained every 10-15 minutes into oil drums stored <br /> nearby. He stated approximately 3-5 drums were generated per shift. During the inspection the crusher was not <br /> running, nor was any oil removed from the secondary containment. The secondary containment overflows once <br /> every couple of days. <br /> All hazardous waste tanks shall be marked with the words"Hazardous Waste" and the accumulation start date. <br /> Immediately ensure that all hazardous waste tanks are marked with the required information. <br /> This is a Class II violation. <br /> 502 CCR 66265.192(a) Failed o comply with new hazardous waste tank system assessment requirements. <br /> Facility does not have a to ik assessment for the used oil tank under the filter crusher(Kruncher). The owner or <br /> operator of a hazardous w aste tank shall obtain a written assessment reviewed and certified by an independent, <br /> qualified, professional eng neer, registered in California attesting that the system has sufficient structural integrity, is <br /> acceptable for the transfer ing, storing, and treating of hazardous waste, and that the tanks and containment system <br /> are suitably designed. Immediately have an assessment prepared for the used oil tank under the crusher. Submit a <br /> schedule showing when this will be accomplished to the EHD. <br /> This is a Class I violation. <br /> 507 CCR 66265.195 Failed to onduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> Inspections of the hazard s waste tank system was not performed and documented. The following items are <br /> required to be inspected a least daily: <br /> 1. overfill/spill control a uipment; <br /> 2. aboveground portion of the tank system to detect corrosion or releases of water; <br /> 3. data gathered from monitoring and leak-detection equipment; <br /> 4. outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br /> hazardous waste; <br /> 5. for uncovered tanks, the level of waste in the tank. <br /> Immediately begin required inspections of the hazardous waste tank system, and document the items inspected. <br /> Submit a copy of the inspection log for the next 30 days to the EHD. <br /> This is a Class II violation. <br /> Page 11 of 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.