Laserfiche WebLink
John and Margaret Marci Property Page 2 <br /> 2%9 Loomis Road March 23,2009 <br /> Stockton,California 95205 <br /> The EHD conditionally approves the three pilot tests. GTI proposes to use monitoring wells MW-5 <br /> and MW-7, screened between fifty-five and seventy feet bsg, and MW4, screened between <br /> approximately sixty and eighty feet bsg, as observation wells. Groundwater is currently at <br /> approximately fifty-three feet bsg,-thus there is a minimum of one-and-a-half feet of water above <br /> the screened intervals of MW-5 and MW-7 and over sic feet of water above the screened interval of <br /> MW4. As a result, it is unlikely a drop in pressure will be observed in these three monitoring <br /> wells. This is also true for injection well IW-101, and extraction wells EW-101, EW-102, and <br /> EW-103, all screened between fifty-five and fifty-seven feet bsg. Measurements may be taken to <br /> detect pressure reductions in these wells; however, the EHD does not expect to obtain useful data. <br /> Instead, the EHD believes the three pilot tests should use injection well IW-1, and extraction wells <br /> EW-1, EW-2, EW-3, and EW-6 as observation wells since these wells are screened within the <br /> vadose zone. This means the first test would involve extracting groundwater and soil vapor from <br /> proposed well EW4 while measuring vacuum, depth to water, and collecting PID readings in <br /> observation wells 1W-1, EW-1, EW-2, EW-3, and EW-6; the second test would involve extracting <br /> soil vapors from proposed well EW-6 while measuring vacuum,depth to water, and collecting PID <br /> readings in observation wells IW-1, EW-1, EW-2, and EW-3; and the third test would involve <br /> extracting groundwater and soil vapors from proposed well EW-5 while measuring vacuum, depth <br /> to water, and collecting PID readings in observation wells IW-1, EW-1, EW-2, EW-3, and EW-6. <br /> In addition,monitor pressure and depth-to-water in a monitoring well screened into the vadose zone <br /> and located outside the potential radius of influence to allow for corrections in atmospheric pressure <br /> variations and depth-to-water fluctuations. <br /> Please submit a well permit application and permit/inspection fee of$404 to the EHD and notify <br /> the EHD at least a week prior to initiating the fieldwork. Complete the pilot tests by June 12,2009, <br /> 0 _ and submit the report to the EHD within sixty days of completing the tests. Please contact Vicki <br /> McCartney at(209)468-9852 or by e-mail at vmccartna(7a,sicehd.com if you have any questions. <br /> Sincerely, <br /> ( ` Victoria L.McCartney,REHS Nuel C. enderson,Jr.,PG <br /> Senior Registered Environmental Health Specialist Engineering Geologist <br /> C. c: Mr. Reza Namdar Ghanbari, Geological Technics Inc., 1101 7' Street, Modesto, California <br /> 95354 <br /> ►- %;J` { Mr. James L.L. Barton, PG, California Regional Water Quality Control Board Central Valley <br /> Region, 11020 Sun Center Drive,Suite 200,Rancho Cordova,California 95670 <br /> CA <br /> Gd <br />