f <br /> CAMBRIA <br /> Based on the perched water analytical results, SJCEHD has requested that additional <br /> investigation be conducted in the northwestern dispenser area. <br />` Technical Rationale for Proposed Scope of Work <br /> • TPHg and benzene have been detected in soil near the northwestern dispenser. The <br /> vertical extent of TPHg and benzene in soil is defined at 35 fbg by boring B-1. The <br /> lateral extent of TPHg and benzene in soil is defined to the east and south by results from <br /> boring B-2 and SB-1, respectively. Fuel oxygenates have not been detected in soil from <br /> this area. <br /> Perched water was encountered at approximately 14.7 fbg in soil boring B-1, located <br /> immediately west of the northwestern dispenser. The sample collected at 17 fbg in <br /> boring B-1 was not saturated, delineating the vertical extent of the perched water zone. <br /> The boring log for B-1 is included in Appendix A. <br /> f • TPHg and benzene were detected in a.grab water sample from the perched water zone <br /> described above. The lateral extent of the perched zone is delineated to the east and <br /> south by results from boring B-2 and SB-1, respectively, as it was not encountered in <br /> either boring. The boring logs from these borings are included in Appendix A. <br /> • Cambria proposes to drill two soil borings north and west of the northwestern dispenser <br /> to determine the-lateral extent of the perched water zone and to assess petroleum impact <br /> to that zone. The borings will be advanced to a depth to confirm vertical delineation of <br /> the perched zone has been achieved. <br /> f Work Tasks <br /> Permit: Cambria will obtain a well permit from SJCEHD. <br /> Site Safety Plan: A Site Safety Plan will be prepared for field work. <br /> Utility Clearance: Proposed drilling locations will be marked and their locations cleared through <br /> Underground Service Alert prior to drilling. <br /> 0832 3 <br />