Laserfiche WebLink
Project 113-13 <br /> March 30,1993 <br /> Page 2 <br /> A fourth monitoring well was installed by Parker Environmental Services <br /> on September 6, 1991 Soil samples analyzed from the boring were all non detect fore <br /> TPH-g and BTEX Groundwater samples obtained on September 11, 1991 from all <br /> four morutonng wells were also non-detect for TPH-g and BTEX Depth to <br /> groundwater was 28 to 29 feet below ground surface <br /> An aquifer pump test was done by Parker Environmental Services at the site October <br /> 15-16, 1991, and it showed that all four monitoring wells are in the same aquifer. <br /> At thus time no cleanup efforts have been implemented Decisions concerning <br /> future investigations or remediation will be discussed after four quarterly <br /> monitoring reports are completed. <br /> II. Current Activities <br /> Groundwater samples were obtained on March 17, 1993 Prior to sampling, <br /> groundwater elevation measurements were obtained Results are presented in the <br /> table below <br /> Table 1 <br /> Cheaper Store #76 <br /> 890 North Main Street, Manteca, California <br /> Groundwater Measurement Results* <br /> Measured on March 17, 1993 <br /> Wl Elevation MWA MW-2 MW-3 MW-4 <br /> el3312 33.E <br /> Depth to GW -24 82 33 55 ______3-3-66— <br /> 24.70 2510 -2539 <br /> GW Elevation <br /> 8.30 852 8.45 827 <br /> * elevation above mean sea level, in feet <br /> Shallow groundwater measurements indicate the water table is approximately 41 <br /> feet higher than measurements taken in September, 1991 As shown on the attached <br /> groundwater flow direction drawing, the flow direction is toward the southeast, <br /> unchanged from the September, 1991, measurements. <br /> Each monitoring well was purged using an electric submersible pump prior to <br /> sampling Approximately 8 gallons was removed from each well, which equaled <br /> five to six well volumes per well All purge water was placed in a sealed metal 55 <br /> gallon drum (DOT 171-1) After each well was purged, a sample was taken using a <br /> disposable PVC bailer The water was placed in three 40 milliliter vials and a 1-liter <br /> amber container filled so that there was no air (head space) remaining in them <br /> Samples were labeled and placed on ice in a cooler for transport to a state certified <br /> hazardous materials testing Iaboratory, McCampbell Analytical of Pacheco, <br /> California Before the next well was purged and sampled, the pump was run in one <br /> bucket with non-phosphate detergent and two separate buckets with tap water The <br /> Parker Environmental Services 4185 Rialto Court Pittsburg CA 94565-6116 <br /> Phone (510) 439-1024 Fax (510) 439-2566 <br />