• • Pace Analytical Services,Inc. <br /> (� <br /> 2795 Second Street-Suite 300 <br /> IaceAnalyfical' <br /> Davis,CA 95618 <br /> nvrxpacela5scam (530)297-4800 <br /> QUALITY CONTROL DATA <br /> Project: DIESEL LINE SAMPLING <br /> Pace Project No.: 1246740 <br /> QC Batch: DAMP/1093 Analysis Method: EPA6010B <br /> QC Batch Method: EPA 3050 Analysis Description: 6010 MET <br /> Associated Lab Samples: 1246740001,1246740002,1246740003 <br /> METHOD BLANK: 207441 Matrix: Solid <br /> Associated Lab Samples: 1246740001,1246740002,1246740003 <br /> Blank Reporting <br /> Parameter Units Result Limit Analyzed Qualifiers <br /> Lead mg/kg ND 0.50 05/12/1509:27 <br /> LABORATORY CONTROL SAMPLE: 207442 <br /> Spike LCS LCS %Rec <br /> Parameter Units Cone. Result %Ree Limits Qualifiers <br /> Lead mg/kg 50 51.0 102 80-120 <br /> MATRIX SPIKE&MATRIX SPIKE DUPLICATE: 207443 207444 <br /> MS MSD <br /> 1246606001 Spike Spike MS MSD MS MSD %Rec Max <br /> Parameter Units Result Cone. Cones Result Result %Rec %Rec Limits RPD RPD Qual <br /> Lead mg/kg 17.9 48.5 47.6 68.9 56.4 105 81 75-125 20 20 <br /> Results presented on this page ares In Ne units Indicated by the"Units"column except where an alternate unit is presented to the right of the result. <br /> REPORT OF LABORATORY ANALYSIS <br /> This report shall not be reproduced,except in full, <br /> Dale:05/1412015 07:20 PM without the written consent of Pace Analytical Services,Inc.. Page 8 of 17 <br />