Phase 11 Environmental Site Assessment <br /> Manteca Multimodal Station Project,Southeast of Moffat Boulevard and Main Street Manteca, California <br /> LABORATORY ANALYSIS <br /> The soil and groundwater samples were transported to Associated Laboratories-of Orange, <br /> California under chain-of-custody documentation. The soil and groundwater samples were <br /> analyzed as follows: <br /> Former Standard Oil Company Supply Station and Industrial Adjacent Land Uses-The soil <br /> samples from 5 feet below grade and groundwater samples from B 1 through B5 were analyzed <br /> for full range total petroleum hydrocarbons (TPH)by EPA Method 8015M and volatile organic <br /> compounds (VOCs) by EPA Method 8260B. The deeper soil samples were placed on hold at the <br /> laboratory pending the analytical results of the 5-foot samples. Based on the results of the 5-foot <br /> deep samples (described in the Results section below), further analyses of the deeper soil <br /> samples collected from B1 through B5 (10, 15, 20 and 25 feet deep samples)were not <br /> conducted. <br /> Historic Railroad Spurs-The 16 soil samples collected from 0.5 feet below grade from RB 1 <br /> through RB 16 were analyzed for TPH by EPA Method 8015M and total metals by EPA Method <br /> 6010B. Eight soil samples (RB2, RB4, RB6, RB8,RB 10,RB 12, RB 14, and RB 16)from 0.5 feet <br /> below grade were analyzed for VOCs by EPA Method 8260B. Four composite soil samples (1:4 <br /> ratio) from 0.5 feet below grade were analyzed for chlorinated herbicides by EPA method <br /> 8151A. The 2-feet deep soil samples were placed on hold at the laboratory pending the <br /> analytical results of the 0.5-foot samples. Based on the results of the 0.5-foot deep samples <br /> (described in the Results section below),the 2-feet deep soil samples collected from B4 and B 14 <br /> were also analyzed for lead. <br /> Stained Pavement-The soil sample collected at 1-foot below grade from RB 17 was analyzed for <br /> VOCs by EPA Method 8260B, SVOCs by EPA Method 8270C,TPH by EPA Method 8015M, total <br /> metals by EPA Method 6010B, organochlorine pesticides by EPA Method 8081A,chlorinated <br /> herbicides by EPA Method 8151A, and PCBs by EPA Method 8082. The 5-foot deep soil sample <br /> was placed on hold at the laboratory pending the analytical results of the 1-foot sample. Based on <br /> the results of the 1-foot deep soil sample(described in the Results section below), further <br /> analyses of the 5-foot deep soil sample collected from B 17 were not conducted. <br /> RESULTS <br /> During the current assessment, the soil consisted of silty sand and sand from surface to between <br /> 14 and 18 feet below grade and clay and sandy clay from between 14 and 18 feet below grade to <br /> 25 feet below grade. Groundwater was encountered in the five borings at between 18 and 22 feet <br /> below grade. Boring logs for the five-borings advanced to 25 feet below grade(B1 through B5) <br /> are included in Appendix 2. Summaries of the analytical results are included in Tables 1 through <br /> 3. Copies of the laboratory analytical reports are included in Appendix 3. <br /> FORMER STANDARD OIL COMPANY SUPPLY STATION AND ADJACENT <br /> INDUSTRIAL LAND USES <br /> Soil and Groundwater Sampling <br /> Five borings(B 1 through B5)were advanced to 25 feet below grade along the southern property <br /> line. Soil samples were collected at 5-foot intervals in each boring. The soil samples collected <br /> at 5-feet below grade were analyzed for TPH and VOCs. As summarized in Table 1, <br /> Rincon Consultants <br /> 9 <br />