Laserfiche WebLink
12 January 1998 <br /> • - AGE-NC-95-0103 - <br /> - Page 3 of 7 - - <br /> - 1997 soil vapor samples were collected in Tedlar bags from the influent and effluent streams The <br /> - samples were labeled, placed in a cool ice chest and transported under chain-of-custody to MAI <br /> 3.0. FINDINGS <br /> 3 1 RELATIVE GROUND WATER ELEVATION AND GRADIENT <br /> - <br /> The relative elevation of grodnd water in each well was calculated by subtracting the ground water <br /> depth from the surveyed casing elevation relative to mean sea level (Table 1) The ground water <br /> - elevation decreased approximately 0 7 feef between April and September 1997 The ground water <br /> flow direction at the site was generally radially inward toward the northern portion of the property <br /> underlying the parking area of the site (Figure 3) <br /> 3 <br /> 32 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> TPII-g was detected in the'water_ samples from wells MW-1, MW-3, MW-4 and MW-5 at <br /> concentrations of 2,800 parts per billion (ppb, reported as micrograms per liter), 6,800 ppb, 78,000 <br /> ppb and 1,000 ppb, respectively Benzene was detected in wells MW-I, MW-3 and MW-4 at <br /> concentrations of 170 ppb, 150 ppb and 12,700 ppb,respectively Benzene was not detected in wells <br /> MW-2, MW-5 and MW-6 Other BTE&X compounds were detected in these wells at concentrations <br /> as High as 13,00Vppb (xylene, MW-4) Ethylbenzene and xylenes were detected in MW-3 at <br /> ` concentrations of 340 ppb and 330 ppb,respectively Petroleum hydrocarbons were not detected in <br /> the samples collected from wells MW-2 and MW-6 <br /> A water sample collected from vapor extraction well VE-3 was also analyzed during the last quarter <br /> TPH-g was detected in the water sample at a concentration of 5,400 ppb Benzene was detected at <br /> 120 ppb,toluene was detected at 93 ppb,ethylbenzene was detected at 150 and xylenes was detected <br /> at 760 ppb <br /> MTBE was detected only in the ground water samples collected from wells MW-1 and VE-3 at <br /> - concentrations of 80 ppb and 34-ppb, respectively TBA was detected in ground water samples <br /> collected from wells MW-1, MW-3 and VE-3 at concentrations of 93 ppb, 79 ppb and 260 ppb, <br /> respectively DIPE was also detected in samples collected from wells MW-5 and VE-3 at <br /> concentrations of 14 ppb and 15,ppb, respectively ETBE and TAME were not detected at the site <br /> The analytical results of current and previous samples are summarized in Table 2 and Table 3 The <br /> _ laboratory-report (MAI sample ID Nos 83733 through 83739) and chain-of-custody form are <br /> = included in Appendix C <br /> - - Advanced GeoEnvironmental,Inc <br />