i <br />' 24 January 2006 <br /> AGE-NC-99-0570 <br />' Page 3 of 5 <br />' 3.0. FINDINGS <br /> Ground water elevation, flow direction, and gradient were determined from field data collected on <br />' '28'July 2005 Hydrocarbon impact to groundwater was assessed by laboratory analysis of the ground <br /> water samples <br />' 3 1 GROUND WATER ELEVATION AND GRADIENT <br />' The depth to ground water ranged from 13 14 feet below the top of the well casing(btoc) in MW-3 <br /> to 14 50 feet btoc in MW-5 The relative ground water elevation ranged from 7 41 feet below mean <br /> seal level(MSL)in MW-3 to 10 18 feet below MSL in MW-5 During this monitoring event,the top <br /> of the ground water table occurred within the screened intervals of the wells <br /> Ground water was inferred to be flowing north-northwest under a significant hydraulic gradient of <br />' approximately 0 027 foot/foot(ft/ft) The ground water elevation contours are depicted on Figure 3 <br /> • 3 2 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br />' TPH-g was detected in samples MW-1, MW-2 and MW-5 at concentrations of 5,400 micrograms <br /> per liter(gg/1), 1,700 µg/1 and 200 µg/1,respectively TPH-d was not detected in any of the samples <br /> analyzed <br />' BTEX compounds were detected in wells MW-1,MW-2 and MW-3 at maximum concentrations of <br /> 39 gg/1 benzene(MW-1), 6 0 µg/l toluene (MW-2), 460 µg/l ethylbenzene (MW-1)and 1,155 µg/1 <br /> xylenes (MW-1) <br /> MTBE was detected in wells MW-1, MW-2 and MW-3 at concentrations of 59 µg/l, 3 7µg/I and <br /> 6 0 gg/l, respectively <br /> No other target analytes were detected at or above laboratory reporting limits in any of the samples <br /> analyzed Laboratory results of ground water samples are summarized in Table 2 The laboratory <br /> report(CTEL Project No CT214-0507191),quality assurance/quality control(QA/QC)reports,and <br /> chain of custody form are included in Appendix D Documents confirming the upload of laboratory <br /> Ielectronic deliverable format (EDF) files and depth to water measurements to GeoTracker are <br /> included in Appendix E <br /> IAdvanced GeoEnvironmentel,Inc <br />