My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006056
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
1624
>
2900 - Site Mitigation Program
>
PR0516942
>
ARCHIVED REPORTS_XR0006056
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2020 3:38:40 PM
Creation date
3/23/2020 3:36:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006056
RECORD_ID
PR0516942
PE
2950
FACILITY_ID
FA0012945
FACILITY_NAME
DON INVESTMENTS (TENANTS)
STREET_NUMBER
1624
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16337007
CURRENT_STATUS
01
SITE_LOCATION
1624 NAVY DR
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 4, 2002 <br /> NOA ENVIRONMENTAL PROJECT NUMBER: LE00-429 <br /> approximately 20 feet apart,a site map showing the location of the borings can be found in Appendix <br /> F <br /> 1 Pursuant to section III 1 a ofthe Tri Regional Board guidelines, soil samples were to be taken every <br /> five feet during the excavation of the borings According to the March 26,2001 proposal, sampling <br />' was to begin at a depth of ten and a half(10 5) feet below ground surface, and boring was to be <br /> terminated at the capillary fringe (Appendix E) On the day of the drilling, however,moist soil was <br /> encountered at nine(9) feet down, so the drilling was terminated, two (2) samples were taken from <br />' each boring at this level(Appendix F) These samples were sent to Sequoia Analytical for laboratory <br /> testing <br />' Sequoia Analytical reported the following results on June 22, 2001 <br /> Table 2 Sequoia Anal ical Results on Holt Soil Borings <br /> Boring Extractable ; Reporting Limit BTEX (mg/kg) Reporting Limit <br /> Hydrocarbons (mglkg) (mg/kg) <br /> (mg/kg) <br /> B1-1-1 14 10 ND i 00050 <br /> BI-1-II ND 250* ND 00050 <br /> 10 <br /> 132-1-I 19 R 10 ND 00050 <br /> 132-1-II 1 6 1 0 ND 00050 <br /> B3-1-1 17 10 ND 00050 <br />' B3-1-I1 ND 50* ND 00050 <br /> *Please see explanatory memomndian from Mr lion Sobel mduded in Appendix F <br /> A copy of this Sequoia Analytical report can be found in Appendix F <br /> VII. RE UEST FOR CLOSURE <br /> Mr Harlan Knoll, of the San Joaquin County Local Health District, received a copy of the <br /> Underground Storage Tank Closure Investigation Workplan prepared by NOA Environmental on <br /> March 26, 2001 (Appendix E),and it was with Ins consent that the above testing was performed No <br /> further site testing was requested by Mr Knoll at any phase of this project,neither in his Inspection <br />' Report from the date of the tank removal nor after lus receipt of the Underground Storage Tank <br /> Closure Investigation Workplan Mr Knoll also received the results ofthe Sequioa Analytical tests, <br /> along with a letter, dated August 7, 2001, requesting the issuance of a No Further Action statement <br /> (Appendix F) <br /> • <br />' 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.