Laserfiche WebLink
R EIV -61�evinef icke•Recon <br /> ENGINEERS,HVDfiOGEOLOGISTS 8 APPLIED SCIENTISTS <br /> SEP 3 <br /> August 29, 1997 ENVIRONMENTAL HEALTH 4111.90-001 <br /> PERMIT / SERVICES <br /> via U.S. mail <br /> TO: PARTIES ON THE ATTACHED DISTRIBUTION LIST <br /> Subject: Bimonthly Letter Report for June 1 through July 31, 1997, Lincoln Center, <br /> Stockton, California <br /> Dear Interested Parties: <br /> On behalf of the Settling Dry Cleaning Defendants, Levine-Fricke-Recon Inc. presents this letter <br /> report summarizing activities for the period of June 1 through July 31, 1997 ("the bimonthly <br /> period") at Lincoln Center, located in Stockton, California ("the Site," as defined in the First <br /> Final Consent Decree Order, Judgment and Reference To Special Master, filed with the Court on <br /> January 19, 1996). The information in this letter report is provided pursuant to <br /> Sections IV(A)(1)(f) and IV(F) of the "Permanent Injunction Governing Investigation, Monitoring, <br /> and Testing of the Hazardous Substance Contamination at and Emanating from Lincoln Center and <br /> Order of Reference to Special Master," issued by Judge Levi of the United States District Court, <br /> Eastern District of California, and filed on August 16, 1993. <br /> Ongoing Data Collection Activities <br /> The following data collection activities were conducted at the Site during the bimonthly period: <br /> • Newly installed B-zone monitoring wells MW-203B-1, MW-203B-2, and MW-203B-3 were <br /> developed and sampled on June 5, 1997. Newly installed A-zone monitoring wells MW-103A, <br /> MW-105A, MW-106A, and MW-107A; newly installed B-zone monitoring wells MW-200B <br /> and MW-201B; and newly installed C-zone monitoring well MW-300C were developed and <br /> sampled from June 9 through June 16, 1997 (see Figure 1 for locations). <br /> • Fluid levels were measured in site monitoring wells on June 17 and July 14, 1997. Table 1, <br /> attached, presents a summary of groundwater elevation data for these months. <br /> • Cone penetrometer testing (CPT) and push-in polyvinyl chloride piezometer (PIPP) sampling <br /> were conducted at plume perimeter locations on Cameron Way, Seward Way, McClellan <br /> Way, and Benjamin Holt Drive on July 15 through July 22, 1997 (see Figure 1 for locations). <br /> • Pilot borings PB-204131 and PB-204132, and B-zone monitoring well MW-204B were installed <br /> at the plume perimeter location in the Thrifty/Payless parking lot at Lincoln Center from <br /> July 7 through July 12, 1997 (see Figure 1 for locations). <br /> • Pilot borings PB-301C1 and PB-301C2 were installed at the plume perimeter location on the <br /> Pacific Avenue frontage road east of Lincoln Center in the vicinity of the Bank of Stockton <br /> 1900 Powell Street, 12th Floor, Emeryville, California 94608-1827 • (510) 652-4500 • fax (510) 652-2246 <br /> Offices Worldwide <br />