and cooler ID, and stored with the other samples until they are deli- <br /> vered for analysis to the laboratory. Trip blanks are not opened in the <br /> field. One trip blank set is sent per cooler of samples per day. <br /> 4.4.2 Field Blanks <br /> Field blanks check for contamination of samples due to factors at the <br /> well site. For a field blank, a volatile organic compound (VOC) vial set <br /> is taken empty to the field and filled at the well site with organic-free, <br /> deionized water at the time the well is sampled. Then this sample is <br /> logged into the field notebook and labeled with a QC number for sub- <br /> mittal to the lab. One field blank is submit-ted every day. <br /> 4.4.3 Field Duplicates <br /> Sometimes referred to as a split or replicate, a field duplicate is a check <br /> on field technique and lab consistency. Two samples from a single <br /> bailer are filled at the same sampling location. One is labeled as the <br /> actual hydraulic sample and the other is given a QC number. Preserva- <br /> tion and shipping of samples and their duplicates is identical. One du- <br /> plicate sample will be identified for laboratory analysis for every 10 <br /> samples collected. If less than 10 samples are collected, there will be <br /> one duplicate sample one per sampling event. <br /> 4.4.4 Decontamination and Rinsate Samples <br /> Water used to clean nondisposable sampling equipment will be sam- <br /> pled in the field, as follows: <br /> • Each fresh batch of Alconox Washing Solution will be sampled. <br /> • Steam-cleaning feed water will be sampled prior to use (cold). <br /> • Steam-cleaning water will be sampled from the steam-cleaner out- <br /> put (hot). <br /> • Deionized carbon-free water contained in the water sprayer will be <br /> sampled. <br /> • Deionized carbon-free water will be sampled as it flows off the <br /> sampler during the final rinse. <br /> 4.4.5 Matrix Spike/Matrix Spike Duplicate for Soil Samples <br /> Matrix spikes and matrix spike duplicates are prepared in the laboratory <br /> to help determine long-term precision and accuracy of an analytical <br /> method on various matrices. A matrix spike and matrix spike dupli- <br /> 4-4 <br />