Laserfiche WebLink
s`. <br /> o- <br /> 7-C CONCLUSIONS <br /> Based upon the data contained herein, the following are <br /> concluded: <br /> - Ground water was not encountered in any of the borings to <br /> the maximum depth explored of 51.5 feet. <br /> No TPH-G, benzene, xylenes or ethylbenzene were detected <br /> in any of the samples collected from boring H-5. <br /> - Toluene (ranging from 0.01 to 0.14 ppm) was the only <br /> aromatic hydrocarbon encountered in the samples obtained <br /> from boring B-5, and these concentrations are not <br /> problematic. <br /> - No organic lead was detected in any of the samples <br /> tested. <br /> - <br /> The concentrations of total and soluble lead are well <br /> below the standards contained in Title 22. <br /> Elevated concentrations of TPH-G, toluene, xylenes and <br /> ethylbenzene were detected in seven of the ten samples <br /> obtained from boring B-6. <br /> - Further site characterization is necessary in order to <br /> define the source(s) and extent of contamination. <br /> r _ <br /> Project No. 1.232 -g- <br /> Iy <br /> ENVIRONAMAITAL AUDIT,INC., <br /> iro <br />