My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007901
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5400
>
2900 - Site Mitigation Program
>
PR0522692
>
ARCHIVED REPORTS_XR0007901
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2020 4:44:27 PM
Creation date
4/2/2020 3:34:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007901
RECORD_ID
PR0522692
PE
2957
FACILITY_ID
FA0015465
FACILITY_NAME
FORMER MONTGOMERY WARDS AUTO SRV CTR
STREET_NUMBER
5400
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10227008
CURRENT_STATUS
01
SITE_LOCATION
5400 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOIL VAPOR EXTRACTION PILOT SW WORK PLAN San Joaquin County <br /> Montgomery Ward Auto Service Center Public Health Services Department <br /> 5400 Pacific Avenue, Stockton CA Site Code 2163 <br /> 1 <br /> APPENDIX A <br />' SUMMARY OF SITE ASSESSMENTS <br />' WASTE OIL UST REMOVAL (1986) <br /> On August 28, 1986, one 550-gallon capacity waste oil underground storage tank (UST) was <br /> removed from the Montgomery Ward site (see Figure 2) One soil sample was collected from <br /> beneath the UST by Canonie Environmental Services Corp (Canome) and tested for total <br /> petroleum hydrocarbons (TPH) using EPA Method 8015, purgeable aromatics using EPA <br /> Method 8020, purgeable halocarbons using EPA Method 8010, and polychlorinated biphenyls <br />' (PCBs) using EPA Method 8080 No TPH, purgeable aromatics or PCBs were detected in the <br /> sample Trichlorofluoromethane (0 05 parts per million [ppm]) was the only purgeable <br /> halocarbons detected Based on these testing results, no additional assessment activities are <br />' required in this area of the Montgomery Ward site <br /> BULK OIL UST REMOVALS (1988) <br /> On June 22, 1988, four bulk oil USTs (two 1,000-gallon and two 500-gallon capacity) were <br /> removed from the Montgomery Ward site (see Figure 2) Two soil samples were collected <br /> from beneath each UST by Canome and tested for TPH, and benzene, toluene, ethylbenzene <br /> and xylenes (BTEX) No TPH or BTEX were detected in any of the samples tested Based on <br /> these testing results, no additional assessment activities are required in this area of the <br /> Montgomery Ward site <br />' GASOLINE UST REMOVALS (1986) <br /> On June 26, 1986, two 10,000-gallon capacity gasoline USTs were removed from the <br />' Montgomery Ward site (see Figure 2) The USTs were used to store regular and unleaded <br /> gasoline A representative of the Sari Joaquin County Public Health Services Department <br /> (SJCPHSD) was reportedly on-site during USTs removal activities The underground product <br />' lines were triple rinsed, stubbed and abandoned in place A concrete slab on which the USTs <br /> were located was also abandoned in place The following summarizes the investigation <br /> activities completed to date at the Montgomery Ward site <br />' PHASE I INVESTIGATION (1988) <br /> In May 1988, A D Selditch & Associates, Inc (ADS) drilled and sampled five borings on <br /> the Montgomery Ward site to determine whether any release had occurred in the former <br /> USTS (SCC <br /> 1✓ 2.) Fou f tl,o 1%nrinrtc f}znrynrrc 1 th_rni4ah d) xvf-rP <br /> vrciniry or Lnc �'dSlJililG US1 J 1 JGG Figure GJ Four vt uta. VVAAaasia t.�.J....b. ��� <br /> located in the former area of the gasoline USTs, and one boring (boring 5) was located in the <br />' west corner of the Montgomery Ward site to determine background soil conditions Borings 1 <br /> and 2, located at the southwest and southeast corners of the USTs, respectively, were drilled to <br /> a depth of 20 feet below ground surface (bgs) Borings 3 and 4 encountered auger refusal at <br /> 12 feet bgs, 1 e , the slab on which the USTs had been located was apparently encountered <br /> Detectable concentrations of TPH ranging from 8 to 38 ppm were encountered in only three of <br /> the samples tested (see Table 1) The detectable concentrations were all present in soil <br />' Project No 1232 A-1 ENVIRONMENTAL AUDIT, INC <br />
The URL can be used to link to this page
Your browser does not support the video tag.