GENERAL NOTES
<br />GENERAL REQUIREMENTS:
<br />A. DRAWINGS. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF
<br />WORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERT
<br />ARCHITECT TO ANY UNFORESEEN CONSTRUCTION DIFFICULTIES BEFORE
<br />BEGINNING WORK. IN -FIELD REVISIONS SHALL NOT OCCUR WITHOUT ARCHITECT'S
<br />APPROVAL.
<br />B. PRE -CONSTRUCTION MEETING. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENT
<br />ACTIVITY, THE CONTRACTOR SHALL SCHEDULE, WITH OWNERS APPROVAL, A
<br />PRE -CONSTRUCTION MEETING WITH THE LOCAL BUILDING DEPT. OR LOCAL PUBLIC
<br />WORKS DEPT. VERIFY WHICH AGENCY WOULD BE INVOLVED. THE CONTRACTOR
<br />SHALL PROVIDE LOCAL INSPECTOR WITH 24 HOURS NOTICE PRIOR TO INSPECTION
<br />C. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATED
<br />EVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TO
<br />DETAILED DRAWINGS, CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL.
<br />D. CODES 1 PERMITS / REGULATIONS. ALL EXTERIOR SIGNAGE MUST BE SUBMITTED
<br />AND REVIEWED UNDER SEPARATE PERMIT APPLICATION.
<br />CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS NECESSARY OTHER THAN
<br />THE BUILDING PERMIT. CONTRACTOR SHALL ALSO PAY FOR ALL OTHER CHARGES,
<br />FEES OR COSTS CHARGED BY THE BUILDING AND CONSTRUCTION DEPARTMENTS,
<br />UTILITY AGENCIES OR PRIVATE COMPANIES WHICH REQUIRE SUCH COSTS FOR OR
<br />PRIOR TO INSTALLATIONS.
<br />NOTHING IN THE DRAWINGS SHALL BE CONSTRUCTED TO PERMIT AN INSTALLATION
<br />IN VIOLATION OF APPLICABLE CODES AND/OR RESTRICTIONS. SHOULD ANY
<br />CHANGE IN THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH
<br />APPLICABLE CODES AND/OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY
<br />THE ARCHITECT AT ONCE AND CEASE WORK. ALL PARTS PERFORMED UNDER THIS
<br />CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES,
<br />REGULATIONS, RESTRICTIONS, REQUIREMENTS AND CODES.
<br />AMENDED BY GOVERNING CITY & ALL JURISDICTION RULES AND REGULATIONS.
<br />E. DIMENSIONS ARE SHOWN TO FACE OF MASONRY OR CENTERLINE OF OPENING,
<br />UNLESS DETAILED OTHERWISE ON DRAWINGS.
<br />DO NOT SCALE DRAWINGS, THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON
<br />THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF
<br />ANY DISCREPANCIES ARE FOUND.
<br />THE CONTRACTOR SHALL VERIFY ALL ROUGH -IN DIMENSIONS FOR THE EQUIPMENT
<br />FURNISHED AND INSTALLED BY HIMSELF/HERSELF OR OTHERS.
<br />THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS
<br />THROUGH SLABS, WALLS, CEILINGS AND ROOFS.
<br />F. SHOP DRAWINGS REVIEW. PROVIDE SHOP DRAWINGS FOR THE
<br />ARCHITECTS/OWNERS AND AS REQUIRED BY THE CITY PRIOR TO CONSTRUCTION.
<br />G. CONTRACTOR TO FRAME OPENINGS IN WALLS, CEILINGS AND FLOORS FOR H.V.A.C.
<br />AND OTHER MECHANICAL OR ELECTRICAL WORK WHERE REQUIRED AND NOT
<br />OTHERWISE SHOWN ON THE PLANS.
<br />H. COMPLY WITH APPLICABLE REGULATIONS FOR BARRIER -FREE FACILITIES
<br />INCLUDING:
<br />1). MAXIMUM THRESHOLD HEIGHT TO BE ONE HALF INCH (1/2") ALONG
<br />ACCESSIBLE ROUTE OF TRAVEL.
<br />2). STAIR NOSINGS TO BE FLUSH, SLIP RESISTANT AND ROUNDED TO RADIUS OF
<br />ONE HALF INCH (112")MAXIMUM.
<br />DOORSIWINDOWS:
<br />A. GLAZING. PROVIDE GLAZING PER CITY CODES:
<br />INSULATED UNITS SHALL BE CLASS 40 GLAZING WITH LOW ARGON GAS.
<br />GLAZING IN LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS PANES IN DOORS,
<br />GLAZING WITHIN A 24" ARC OF A DOOR OPENING, GLAZING WITHIN 18" OF THE
<br />FLOOR (AND IS OVER 9 SQ. FT. PER PANEL) SHALL BE TEMPERED GLASS OR
<br />LAMINATED SAFETY GLASS PER CODE.
<br />GLAZING U -VALUE (AMMA TESTED) U-40 MAXIMUM.
<br />FIRE PROTECTION:
<br />A. GG TE) EXTENIDTI IE EXISTING AUTOMA:RG FIRE SPRINKLER SYSTEM AS REGUIRED.
<br />A_ lIP PIr_c nCt]ART-PACAfT PR_ IG TG INSTAI=611TIQNTIF AP121=(CABLE`.
<br />r ee �� � e ee e�e� PAR e e ori e � t � i � u v� e � e�
<br />B. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY INTERNATIONAL BUILDING CODE
<br />AND LOCATE PER FIRE MARSHAL'S DIRECTION. 1 FIRE EXTINGUISHER PER 3,000 S.F.
<br />OF BUILDING AREA WITHIN 75'-0" TRAVEL DISTANCE BETWEEN EXTINGUISHERS.
<br />C. MAINTAIN STRUCTURAL AND FIRE RESISTIVE INTEGRITY AT EXTERIOR AND RATED
<br />INTERIOR WALL PENETRATIONS FOR ELECTRICAL, MECHANICAL, PLUMBING AND
<br />COMMUNICATIONS CONDUITS, PIPED AND SIMILAR SYSTEMS PER CITY'S CODE,
<br />THERMAL/MOISTURE PROTECTION:
<br />A. OPENINGS. ALL OPENINGS TO BE CAULKED, SEALED OR WEATHER-STRIPPED,
<br />ALL FLASHING AND ARCHITECTURAL SHEET METAL TO BE 24 GAUGE GALVANIZED
<br />STEEL, FACTORY PRIMED AND FIELD PAINTED. 10'-0" LENGTHS, PER SMACNA
<br />MANUAL UNLESS OTHERWISE NOTED.
<br />B. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER.
<br />BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. USE
<br />POLYURETHANE SEALANTS AT CONCRETE FLOOR AND SIDEWALK JOINTS. ALL
<br />OTHER LOCATIONS USE POLYSULFIDE OR SILICONE.
<br />C. VAPOR BARRIERS. CONTINUOUS APPROVED VAPOR BARRIERS SHALL BE
<br />INSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED.
<br />D. INSULATION. PROVIDE INSULATION PER LOCAL CODE, COMPONENT PERFORMANCE
<br />APPROACH.
<br />DEFERRED SUBMITTALS
<br />• SIGNAGE UNDER A SEPARATE SUBMITTAL AND PERMIT
<br />• KITCHEN HOOD SUPPRESSION SYSTEM
<br />FIRE ALARM (DEFERRED SUBMITTAL)
<br />G.C. COMPLIANCE
<br />OWNER'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS
<br />PRIOR TO START OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT.
<br />TENANT'S GENERAL CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING
<br />CONSTRUCTION PROCEDURES, INSURANCE, ETC., AS SET FORTH BY THE LANDLORD.
<br />SITE ANALYSIS: BUILDING AREA: EXISTING TO REMAIN UNCHANGED BY THIS PROJECT.
<br />COVERAGE: EXISTING TO REMAIN UNCHANGED BY THIS PROJECT.
<br />GENERAL NOTES:
<br />1. PRIOR TO DEMOLITION, VERIFY IN FIELD EXISTING WALLS AND IF ANY STRUCTURAL COLUMNS EXIST.
<br />IF SO, CONTACT ARCHITECT IMMEDIATELY.
<br />2. CONTRACTOR TO MAINTAIN PROPER LIGHTING, SANITATION AND VENTILATION AT ALL TIMES.
<br />3, ALL WORK MUST BE APPROVED BY BUILDING INSPECTOR PRIOR TO COVERING WORK.
<br />4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN A WATER AND WEATHER TIGHT
<br />BUILDING.
<br />5. ALL WORK TO BE PERFORMED TO CODE BY LICENSE CONTRACTORS PERFORMING WORK IN THEIR
<br />SPECIFIC TRADE ONLY.
<br />6. ALL DESIGN, DRAWINGS, AND DETAILS REPRESENT COMPLETE WORK IN PLACE. ARCHITECT SHALL
<br />HAVE NO CONTROL OR CHANGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION.
<br />7. INTERIOR PARTITIONS NOTED ON PLANS MAY BE SHOWN AS NOMINAL DIMENSIONS, SUCH AS 5"
<br />INTERIOR WALL REFERS TO GYPSUM BOARD EACH OVER 3-518" STUDS. STUD SPACING IS 24" O.C.
<br />8. ALL DEBRIS GENERATED FROM CONSTRUCTION MUST BE KEPT ON THE SITE IN EITHER AN ENCLOSED
<br />AREA OR HAULED AWAY DAILY, AND DISPOSED OF LEGALLY OFF-SITE.
<br />9. EXTERIOR SIGNAGE IS NOT PART OF THIS CONTRACT OR PERMIT EXCEPT ELECTRICAL ROUGH -IN AND
<br />BLOCKING. SIGN CONTRACTOR SHALL MAKE SEPARATE SUBMITTAL TO THE CITY FOR REVIEW AND
<br />PERMIT.
<br />10. KEEP ALL PIPING AND CONDUIT AS CLOSE TO WALLS AND ROOF DECK AS POSSIBLE AND ALL
<br />DUCTWORK AS CLOSE TO ROOF AS POSSIBLE. WHERE EXPOSED, ALL PIPING CONDUIT AND
<br />DUCTWORK SHALL BE PAINTED UNLESS NOTED. ALL PIPING CONDUIT SHALL BE ORGANIZED IN A NEAT
<br />MANNER RUNNING PARALLEL OR PERPENDICULAR TO ROOF FRAMING MEMBERS.
<br />11. MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS AND
<br />CEILING SHALL NOT EXCEED THAT SET FORTH IN FLAME SPREAD TABLE OF THE BUILDING CODE.
<br />12. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO CONSTRUCTION AND COORDINATE WITH ARCHITECT
<br />ANY CONFLICTS WITH THE PLANS.
<br />13. PERFORM THE REMOVAL, CUTTING, AND DRILLING WITH THE CARE USE OF THE SMALLEST TOOLS SO
<br />AS TO NOT DAMAGE THE STRUCTURAL INTEGRITY OF THE BUILDING.
<br />14. TO SAW CUT AT EXISTING RESTROOM LOCATION, USE SAWS AND COREDRILLS. DO NOT USE
<br />JACKHAMMER UNDER ANY CIRCUMSTANCES.
<br />15. GC TO COORDINATE FIRE ALARM INSTALL WITH LANDLORD, IF REQUIRED BY CITY,
<br />GENERAL CONTRACTOR NOTE:
<br />THE GC MUST SUBMIT SEPARATE DRAWINGS FOR SPRINKLER AND FIRE ALARM WORK
<br />AND SHALL BE UNDER SEPARATE PERMIT - WHEN APPLICABLE.
<br />CONSTRUCTION NOTES
<br />ARCHITECT'S DESIGN WITHOUT CONSTRUCTION PHASE SERVICES
<br />SINCE DIRECT CONSTRUCTION OBSERVATIONS AND REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INCLUDED AS
<br />PART OF THE ARCHITECT'S BASIC SERVICES, IT IS UNDERSTOOD THAT SUCH RESPONSIBILITIES WILL BE ASSUMED BY OTHERS.
<br />NDG AVAILS ITSELF TO THE CLIENT, THE CONTRACTOR, AND ANY OTHER PARTIES AS NECESSARY (VIA TELEPHONE, FAX, AND
<br />EMAIL) IN ORDER TO ASSIST IN PROVIDING CLARIFICATIONS OR RESOLVING ISSUES AND PROBLEMS THAT MAY ARISE.
<br />ALTHOUGH MANY ISSUES CAN BE EASILY ADDRESSED WITHOUT THE ARCHITECTS INVOLVEMENT, THERE ARE TIMES WHEN
<br />PARTICIPATION IS ADVISABLE. DETERMINATION OF WHEN INVOLVEMENT IS APPROPRIATE IS LEFT TO THE PROFESSIONAL
<br />DISCRETION OF THE CONTRACTOR. IT IS UNDERSTOOD THAT THE CLIENT ANDIOR THE CONTRACTOR ASSUMES ALL
<br />RESPONSIBILITY FOR INTERPRETATION OF THE DRAWINGS, AND ANY OTHER SUPPLEMENTAL INFORMATION, AND WHEN THE
<br />ARCHITECT IS DENIED THE OPPORTUNITY TO PROVIDE CLARIFICATIONS OR PARTICIPATE IN CHANGES TO THE DESIGN OR THE
<br />RESOLUTION OF ISSUES OR PROBLEMS, ALL PARTIES WAIVE ANY CLAIMS AGAINST THE ARCHITECT THAT MAY BE IN ANY WAY
<br />CONNECTED THERETO. NDG IS HELD HARMLESS FROM LOSS, CLAIM, OR COSTS ARISING OR RESULTING FROM MODIFICATIONS
<br />OR CHANGES MADE TO THE DESIGN (WITHOUT THE KNOWLEDGE OF THE ARCHITECT) DUE TO CONDITIONS OR
<br />CIRCUMSTANCES (ANTICIPATED OR NOT) BEYOND THE ARCHITECT'S CONTROL.
<br />MECHANICAL, PLUMBING AND ELECTRICAL NOTES
<br />1. KITCHEN HOOD BY MANUFACTURER. REFER TO MANUFACTURER'S INFORMATION AND COORDINATE WITH MECHANICAL
<br />DESIGNS.
<br />2. THE RELATIONSHIP BETWEEN FLOOR SINKS AND NEW WALLS IS CRITICAL TO THE FINAL FIXTURE / EQUIPMENT LAYOUT.
<br />FLOOR SINKS AS SHOWN ON THE PLUMBING PLANS ARE DIMENSIONALLY LOCATED OFF OF NEW PARTITIONS, AND
<br />THEREFORE THE CONTRACTOR MUST COMPLETE PLAN LAYOUT ON SLAB PRIOR TO FINAL LOCATION OF FLOOR SINKS FOR
<br />ACCURATE FINAL PLACEMENT.
<br />3, ELECTRICAL SERVICES ACCESS TO THE SUITE VIA EXISTING OPENINGS IN THE FLOOR SLAB. PANELS, CIRCUITS AND
<br />LIGHTING ARE ALL NEW.
<br />G.G. COMPLIANCE:
<br />OWNER'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO START
<br />OF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERAL
<br />CONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE:, ETC.,
<br />AS SEAT FORTH BY THE LANDLORD.
<br />G.C. COMPLIANCE:
<br />OWNER'S SIGNAGE CONTRACTOR SHALL PREPARE SIGNAGE SHOP DRAWINGS AND SUBMIT TO BUILDING DEPT. &
<br />LANDLORD FOR APPROVAL. ALL SIGNAGE IS UNDER SEPARATE PERMIT.
<br />SITE MAP
<br />W 11 L 1 ! LCIVAIV
<br />PROJECT LDCA TION
<br />CORNER OF
<br />LOWER SACRAMENTO Ra.
<br />W KE -T UMAN RD.
<br />W. IFN TR r BL VD
<br />A TENANT IMPROVEMENT FOR
<br />ECO o a a � a
<br />1401 S. LOWER SACRAMENTO RD,,
<br />LODI, CA 85242
<br />REFERENCE SYMBOLS
<br />DOOR TAG
<br />w
<br />FLASH
<br />FLASHING
<br />PLAM
<br />PLASTIC LAMINATE
<br />REFERENCE
<br />X
<br />ROOM TAG
<br />100
<br />PLYWD
<br />A4
<br />AL
<br />ALUMINUM
<br />WALL SECTION
<br />INSTALLED BY CONTRACTOR
<br />R
<br />RISER, RADIUS
<br />REFERENCE
<br />K
<br />A4
<br />DETAIL REFERENCE
<br />A
<br />REBAR
<br />REINFORCING BAR
<br />REVISION
<br />ARCHITECTURAL
<br />EQUIPMENT
<br />REFERENCE
<br />FIBERGLASS REINFORCED
<br />REF
<br />REFERENCE
<br />AVG
<br />AVERAGE
<br />ABBREVIATIONS
<br />ACP
<br />ACOUSTICAL CLG. PANEL
<br />FLASH
<br />FLASHING
<br />PLAM
<br />PLASTIC LAMINATE
<br />ACT
<br />ACOUSTICAL CLG, TILE
<br />FOIC
<br />FURNISHED BY OWNER
<br />PLYWD
<br />PLYWOOD
<br />AL
<br />ALUMINUM
<br />P3
<br />INSTALLED BY CONTRACTOR
<br />R
<br />RISER, RADIUS
<br />ALUM
<br />ALUMINUM
<br />FO
<br />FINISH OPENING
<br />REBAR
<br />REINFORCING BAR
<br />ARCH
<br />ARCHITECTURAL
<br />FRP
<br />FIBERGLASS REINFORCED
<br />REF
<br />REFERENCE
<br />AVG
<br />AVERAGE
<br />A2.0
<br />PANELS
<br />REV
<br />REVISION
<br />BLDG
<br />BUILDING
<br />FRT
<br />FIRE RETARDANT TREATED
<br />RM, RMS
<br />ROOM, ROOMS
<br />BLKG
<br />BLOCKING
<br />GA
<br />GAUGE
<br />RO
<br />ROUGH OPENING
<br />BR
<br />BRICK
<br />GALV
<br />GALVANIZED
<br />S & V
<br />SATIN AND VARNISH
<br />CMU
<br />CONCRETE BLOCK
<br />GL
<br />GLASS
<br />Sc
<br />SOLID CORE
<br />CT
<br />CERAMIC TILE
<br />GWB
<br />GYPSUM WALLBOARD
<br />SCHED
<br />SCHEDULE
<br />CNDG
<br />CUBIC FEET PER MINUTE
<br />HDWE
<br />HARDWARE
<br />SEC
<br />SECTION
<br />CL
<br />CENTER LINE
<br />HM
<br />HOLLOW METAL
<br />SHT
<br />SHEET
<br />CLG
<br />CEILING
<br />HOR
<br />HORIZONTAL
<br />SPECS
<br />SPECIFICATIONS
<br />CONC
<br />CONCRETE
<br />HT
<br />HEIGHT
<br />SF
<br />SQUARE FEET
<br />CONT
<br />CONTINUOUS
<br />HW
<br />HOT WATER
<br />ST
<br />STEEL
<br />CW
<br />COLD WATER
<br />HWH
<br />HOT WATER HEATER
<br />STOR
<br />STORAGE
<br />DTL
<br />DETAIL
<br />HWT
<br />HOT WATER TANK
<br />STRUCT
<br />STRUCTURAL
<br />DF
<br />DRINKING FOUNTAIN
<br />LAV
<br />LAVATORY
<br />SUSP
<br />SUSPENDED
<br />DIA
<br />DIAMETER
<br />LT
<br />LIGHT
<br />SV
<br />SHEET VINYL
<br />DIM
<br />DIMENSION
<br />MAT'L
<br />MATERIAL
<br />SS
<br />STAINLESS STEEL
<br />DN
<br />DOWN
<br />MAX
<br />MAXIMUM
<br />TB
<br />TELEPHONE MOUNTING BOARD
<br />DR
<br />DOOR
<br />MTL
<br />METAL
<br />TD
<br />TRENCH DRAIN
<br />DS
<br />DOWNSPOUT
<br />MIN
<br />MINIMUM
<br />THRESH
<br />THRESHOLD
<br />DWG
<br />DRAWING
<br />MO
<br />MASONRY OPENING
<br />TYP
<br />TYPICAL
<br />EA
<br />EACH
<br />MUL
<br />MULLION
<br />UNFIN
<br />UNFINISHED
<br />ELEV
<br />ELEVATION
<br />N/A
<br />NOT APPLICABLE
<br />UR
<br />URINAL
<br />EXIST
<br />EXISTING
<br />NIC
<br />NOT IN THIS CONTRACT
<br />VCT
<br />VINYL COMPOSITION TILE
<br />OR EX
<br />NO
<br />NUMBER
<br />VERT
<br />VERTICAL
<br />EXT
<br />EXTERIOR
<br />NOM
<br />NOMINAL
<br />VST
<br />VINYL SAFETY TILE
<br />FDN
<br />FOUNDATION
<br />NTS
<br />NOT TO SCALE
<br />W
<br />WIDTH
<br />FIN
<br />FINISH
<br />OC
<br />ON CENTER
<br />WC
<br />WATER CLOSET
<br />FD
<br />FLOOR DRAIN
<br />OD
<br />OUTSIDE DIMENSION
<br />WD
<br />WOOD
<br />FL
<br />FLOOR
<br />PT
<br />PAINT
<br />WDW
<br />WINDOW
<br />WP
<br />WATERPROOF
<br />CONTACT INFORMATION
<br />CORPORATE INFORMATION:
<br />Joseph Lo, ARIA I CSI
<br />Project Development Department
<br />Project Manager I Ono Hawaiian BBQ
<br />M: 626-741-733810: 909-594-3388 Ext. 141 I F:
<br />949-594-8388
<br />21700 Copley Drive, Suite 320, Di=amond Bar, CA
<br />91765
<br />�V[�'•I�f�[•T,i ... hZialxi�►�i1,1►![r1�71
<br />ATTN: CHRIS NEAL
<br />6501 E. Greenway Pkwy #103-707
<br />SCOTTSDALE, AZ 85254
<br />P: 480.297.5577
<br />F. 480.452.0122
<br />cneal@neptunedg.com
<br />TENANT INFORMATION:
<br />1 Ono Hawaiian BBQ 1
<br />M: 626-741-7338 f O: 909-594-3388 Ext. 141 I F:
<br />909-594-8388
<br />21700 Copley Drive, Suite 320,
<br />Diamond Bar, CA 91765
<br />HEALTH DEPARTMENT:
<br />SAN JOAQUIN COUNTY
<br />ENVIRONMENTAL HEALTH DEPT
<br />1888 east Hazelton Ave.
<br />Stockton, CA 95202
<br />209.468.3420
<br />VENDOR INFORMATION
<br />KITCHENIEQUIPMENT
<br />Action Sales / 17025 Gale Ave.,
<br />City of Industry, CA 91745
<br />(626)810-2277
<br />FURNITURE:
<br />Ming Ja / 9438 Gidley St., Temple City, CA
<br />91780 / (626) 442-5672
<br />SIGN VENDOR:
<br />Success Sign / 2812 Peck Road,
<br />El Monte, CA 91731 / (626) 444-8181
<br />LANDLORD _ INFORMATION:
<br />Director of Development; Scoii Bohrer
<br />(925) 588-2223,
<br />sbohrer@browmandevelopment.com,
<br />119LI1tr ex94ffA["&L�1a
<br />CITY OF LODI
<br />COMMUNITY DEVELOPMENT
<br />221 W Pine St, Lodi, CA 95240
<br />Attn: Nancy Evans
<br />nevans@lodi.gov
<br />EXTERIOR SIGN UNDER SEPARATE PERMIT BY SIGN COMPANY - INSTALLED BY SIGN (COMPANY
<br />SET DATED: 05.74.2078
<br />PROJECT DATA
<br />N
<br />PROJECT NAME: ONO HAWAIIAN BBQ
<br />PROJECT DESCRIPTION: FIRST TENANT WITHIN A NEWLY CONSTRUCTED SPACE,
<br />TENANT IMPROVEMENTS FOR A SMALL RESTAURANT,
<br />INCLUDING DINING, FOOD PREP and RESTROOMS
<br />CONSTRUCTION VALUATION: $180,000
<br />PROJECT LOCATION: 1401 S. LOWER SACRAMENTO RD,
<br />LODI, CA 85242
<br />GOVERNING CODES:
<br />ALL WORK SHALL BE IN COMPLIANCE WITH, BUT NOT LIMITED TO THE
<br />REQUIREMENTS OF THE FOLLOWING AND ANY OTHER STATE AND LOCAL
<br />CODES HAVING JURISDICTION:
<br />BUILDING: 2016 CALIFORNIA BUILDING CODE
<br />MECHANICAL: 2016 CALIFORNIA MECHANICAL CODE
<br />PLUMBING: 2016 CALIFORNIA PLUMBING CODE
<br />ELECTRICAL: 2016 CALIFORNIA ELECTRICAL CODE
<br />ENERGY: 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS
<br />ACCESSIBILITY: THE AMERICANS WITH DISABILITIES ACT AND IMPLEMENTING RULES
<br />ADDITIONAL: 2016 CALIFORNIA REFERENCED STANDARDS CODE:
<br />FIRE: 2013 CALIFORNIA FIRE CODE W/ CITY OF BAKERSFIELD AMENDMENTS
<br />2016 CALIFORNIA GREEN BUILDING STANDARDS CODE
<br />CONSTRUCTION TYPE: VB - NON SPRINKLERED
<br />GROSS AREA: 1,900 SQ. FT.
<br />PER CBC CHAPTER 3, SECTION 303, PAR. 303.1.1 SMALL BUILDINGS AND TENANT SPACES: < 50 OCC,
<br />OCCUPANCY GROUP: B
<br />KITCHENISERVICE AREA 439 SF 1200 = 3
<br />HALLWAY/RESTROOM 322 SF 1 100 = 4
<br />DINING AREA 582 SF / 15 = 39
<br />TOTAL OCCUPANT LOAD: 46
<br />ACTUAL INTERIOR SEATING: 44 SEATS
<br />NO STRUCTURAL WORK IS TO BE PERFORMED UNDER THIS PERMIT.
<br />NO SITE WORK IS TO BE PERFORMED UNDER THIS PERMIT,
<br />(3) EMPLOYEES MAXIMUM AT ANY ONE SHIFT
<br />EXIT REQUIREMENTS - SECTION 1015, TABLE 1015.1 - OCCUPANCY GROUP B:
<br />REQUIRED 46 > 50 = 1 EXIT(S)
<br />PROVIDED: 2 EXIT(S)
<br />NO CHANGE IN PARKING - RI=FER TO PERMITTED SITE PLAN SHELL DOCUMENTS
<br />INDEX OF SHEETS
<br />A0.0
<br />TITLE SHEET
<br />PO
<br />PLUMBING T24
<br />A1.0
<br />GENERAL CONDITIONS NOTES
<br />P1
<br />PLUMBING SYMBOLS & SCHEDULES
<br />A1.1
<br />RESPONSIBILITY SCHEDULES
<br />P2
<br />PLUMBING PLANS
<br />A1.2
<br />ACCESSIBILITY
<br />P3
<br />PLUMBING DETAILS
<br />A1.3
<br />SPECIFICATIONS
<br />P4
<br />PLUMBING ISOMETRICS
<br />A1.4
<br />EXISTING SITE PLAN/ MAP / EXISTING SHELL PLAN
<br />P5
<br />PLUMBING SPECIFICATIONS
<br />A1.5
<br />CALGREEN NON-RESIDENTIAL
<br />A1.6
<br />CALGREEN NON-RESIDENTIAL
<br />E1
<br />ELECTRICAL SPECIFICATIONS
<br />A2.0
<br />FLOOR PLAN
<br />E2
<br />ELECTRICAL LIGHTING POWER PLAN
<br />A2.1
<br />DIMENSIONED FLOOR PLAN
<br />E3
<br />FLOOR PLAN
<br />A3.0
<br />REFLECTED CEILING PLAN
<br />E4
<br />ROOF PLAN
<br />A4.0
<br />RESTROOM PLAN AND ELEVATIONS
<br />E5
<br />TITLE 24
<br />A4.1
<br />INTERIOR ELEVATIONS
<br />E6
<br />TITLE 24
<br />A4.2
<br />INTERIOR ELEVATIONS
<br />A4,3
<br />KITCHEN ELEVATIONS
<br />A5.0
<br />EQUIPMENT PLAN
<br />S-1
<br />STRUCTURAL PLANS
<br />A6.0
<br />DETAILS
<br />S-2
<br />STRUCTURAL DETAILS
<br />A6.1
<br />DETAILS
<br />S-3
<br />STRUCTURAL NOTES
<br />A6.2
<br />DETAILS
<br />M0.1
<br />MECHANICAL T24
<br />M02
<br />MECHANICAL T24
<br />M1
<br />MECHANICAL FLOOR PLAN
<br />M2
<br />ROOF PLAN
<br />M3
<br />MECHANICAL DETAILS
<br />M4
<br />MECHANICAL SPECIFICATIONS
<br />H1
<br />HOOD DRAWINGS
<br />H2
<br />HOOD DRAWINGS
<br />H3
<br />HOOD DRAWINGS
<br />Q
<br />E
<br />O O U
<br />LCV Q
<br />�¢ C:) M
<br />00 C
<br />>- LU U_ v>
<br />Q Q rCD
<br />LU 0
<br />UJ 0 ami
<br />C7 ,
<br />Lj CO
<br />Q
<br />Co
<br />w �
<br />O
<br />CD
<br />w�
<br />THIS DRAWING IS AN INSTRUMENT OF
<br />SERVICE AND AS SUCH SHALL REMAIN
<br />THE PROPERTY OF NEPTUNE DESIGN
<br />GROUP LLC, UNAUTHORIZED USE OF
<br />REPRODUCTEON WITHOUT PERMISSION
<br />OF THE ARCHITECT IS PROHIBITTFD.
<br />THIS DRAWING IS ONLY FOR USE. N
<br />CONNECTION WITH THIS PROJECT AND
<br />SRALL NOT BE USED FOR OTHER
<br />LOCATIONS. COPYRIGHT 2017.
<br />pC
<br />0
<br />W
<br />I_z W
<br />U5; (4
<br />IZI-
<br />( U')
<br />z V
<br />IIZ cn U
<br />0W=
<br />(=�0
<br />0
<br />❑ J
<br />0 Vi
<br />r -i
<br />O
<br />REVISION
<br />DATE: 05.14.2018 1
<br />COVER SHEET
<br />A0.0
<br />
|