Laserfiche WebLink
E1 CaiTdno Tire <br /> Facility No 39-TZ-0883 <br /> Page 2 of 4 <br /> 30 PRC 42953 Using an Unregistered Waste Tire Hauler <br /> At the time of this inspection, the WTF operator stated that they use their own vehicle to transport waste tires to <br /> their other tire shop. Pursuant to this section, on or after January 1, 1995, any person who gives, contracts, or <br /> arran�oes with another person to transport waste tires shall utilize only a person holding a waste tire hauler <br /> registration from the Board, unless the hauler is exempt as specified in section 42954. <br /> 30 PKC 42961.5 manifesting <br /> At the time of this inspection, the WTF operator was unable to provide copies of waste tire manifests to CIWMB <br /> staff. <br /> Pursuant to this section, the Board shall develop a waste tire manifest system for registered waste tires haulers that <br /> complies with the following conditions: <br /> (b) The manifest form shall be signed by the generator, the waste tire hauler, and the processing, collection, <br /> storage, or disposal facility. Each party shall retain one copy of the manifest form. <br /> (f) Each party required to sign a manifest shall maintain it for three years and shall make it available for <br /> review during regular business hours. <br /> 14 CCR 17351 Fire Prevention Measures <br /> At the time of this inspection, adequate fire fighting suppression equipment (water extinguisher and pike pole) as <br /> defined by this section was not onsite. The operator needs to contact the local fire authority and receive written <br /> verification if fire requirements other than those specified in this section are acceptable. <br /> Pursuant to this section, the operator must provide the following fire fighting suppression equipment: <br /> (A) Adequate equipment to aid in the control of fires, including: <br /> • one (1) dry chemical fire extinguisher <br /> • one (1) two and one-half gallon water extinguisher <br /> • one (1) pike pole at least ten feet in length <br /> • one (1) round point and one (1) square point shovel <br /> (B) Adequate water supply for use by the local fire authority. The water supply shall be capable of <br /> delivering at least 1000 gallons per minute for a duration for at least three (3) hours and at least <br /> 2000 gallons per minute for a duration of at least three (3) hours if the sum of altered plus whole <br /> waste tires exceeds ten thousand (10,000). <br /> All of the fire prevention measures referenced in (A) and (B) above shall apply unless the local fire <br /> authority having jurisdiction over the particular facility determines that a different requirement is necessary <br /> or adequate to meet the intent of this regulation for fire control and the protection of life and property. If <br /> such determination is made, written notification from that fire authority shall be provided to the CIWMB. <br />