Laserfiche WebLink
A. <br /> ©2o„s]aaaUCKsC—eeCoNPaN, <br /> STARBUCKS COFFEE <br /> COMPANY <br /> 2401 UTAH AVENUE SOUTH <br /> _ SEATTLE,WASHINGTON 98134 <br /> (206)318-1575 <br /> - - - - =t--- - THESE DRAWINGS AND SPECIFICATIONS ARE <br /> - j CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> PROPERTY OF STARBUCKS WHICH IS HE OWNER OF THE CORPORATION, <br /> IN <br /> G THIS WORK.THEY SHALL NOT BE <br /> REPRODUCED(IN WHOLE OR IN PART),SHARED <br /> ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> THESE DRAWINGS AND SPECIFICATIONS ARE <br /> INTENDED TO EXPRESS DESIGN INTENT FOR A <br /> T 'I -. M PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> SUBJECT TO CHANGE AT ANYTIME)AND DO <br /> U 't- 't NOT REFLECT ACTUAL SITE CONDITIONS. <br /> m — T T — NOR NEITHER <br /> IABIP TY O SHALLA ITY OBLIGATION <br /> HE OTHER(EXCEPT STATED <br /> co TAT <br /> - fi- — — — ABOVE)UNTIL A WRITTEN AGREEMENT IS <br /> G _ T T_* t T_*t T_* FULLY EXECUTED BY BOTH PARTIES. <br /> T <br /> N O© STARBUCKS TEMPLATE VERSION 12017.05.18 <br /> i�11tlI _�, 11tII _�11,tII _�, - <br /> allo / T1TTT —I <br /> — 'I T '1.........:...... '3TC',..-.....- TTT 7777777 <br /> T�TTT <br /> U t 5858 Wilshire Blvd#200 T:323.954.8996 <br /> 00 Las Angeles,CA 90036 F:323.954.8965 <br /> www.valerloinc.com•infoOvalerioinc.com <br /> 2 ARCHITECTL <br /> Q <br /> OF RECORD <br /> C 2A22a y <br /> � E%PINES <br /> 9� <br /> C �G <br /> E <br /> U <br /> C <br /> O <br /> U <br /> 2 <br /> y <br /> O <br /> U <br /> LIFE ACCESSIBILITY PLAN <br /> 1/4"=1,-0" <br /> LU <br /> LU <br /> Ln MEANS OF EGRESS NOTES KEYNOTES LEGEND OCCUPANCY NOTES = 0') <br /> ul J N <br /> Cz <br /> coil OCCUPANCY CLASSIFICATION: B OCCUPANCY ' Lf) <br /> m CAFE:276 SQ.FT./15 SQ.FT./OCC 18.4 OCC U) U <br /> TOTAL OCCUPANTS: 33 p� <br /> I A. EXISTING ACCESSIBLE COMPLIANT PATH OF TRAVEL TO REMAIN. 1. THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL RETAIL:115 SQ.FT./60 SQ.FT./OCC 1.9 OCC 11'I G3 Q <br /> U APPLICABLE CODES.IF(E)EXTERIOR ENTRANCE THRESHOLD T T T 'L ¢ U <br /> z B. ALL THE ACCESSIBILITY COMPLIANT BATHROOM FIXTURES TO REMAIN. EXCEEDS REQUIRED ADA MAXIMUM HEIGHT OF I/2",REMOVE AND +.'t+.'t_}. RETAIL ACCESSIBLE SEATING PREP:366 SQ.FT./200 SQ.FT./OCC 1.8000 ¢ Z 0 L <br /> REPLACE W/ACCESSIBLE THRESHOLD.RAISED THRESHOLDS AND TTTTT� BOH:273 SO.FT./200 SQ.FT. OCC 1.4000 Z Q <br /> m C. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET ACCESSIBILITY REQUIREMENTS. FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS TO BE 0 <br /> U Y O <br /> BEVELED W/A SLOPE NO GREATER THAN 1/2"MAX(50%BEVELED). INTERIOR SEATING: QUEUE:46 SQ.FT./5 Sp.FT./OCC 9.2 OCC Ir U `1 <br /> r LU <br /> D. ALL DOORS TO PROVIDE 32"MIN.CLEAR OPENING WHEN OPENED TO 90 DEGREES,U.O.N. PREP 27 SEATS X 5%=1 ADA REQUIRED(2 PROVIDED) UNOCCUPIED:437 SQ.FT. WA Q U <br /> r 2. BARRIER-FREE PATH OF TRAVEL. O O O <br /> m E. CONTRACTOR TO VERIFY EXISTING SITE ACCESSIBILITY COMPLIANCE WITH 2019 CBC. EXTERIOR SEATING: P.O.T.:205 SQ,FT. WA C OO <br /> 3. 30"(160 MM)X 48"(1220 MM)CLEAR FOR WHEELCHAIR ACCESS. 16 SEATS X 5%=1 ADA REQUIRED(1 PROVIDED) TOTAL OCC LOAD: 33 a G o_ N Cn <br /> °1F. IF THE BUILDING INSPECTOR DETERMINES NON-COMPLIANCE WITH ANY ACCESSIBILITY PROVISIONS _ SIE.SIE:.. QUEUE LINE <br /> NOF THE LAW,HE/SHE SHALL REQUIRE COMPLETE,DETAILED PLANS TO THE PLANNING AND BUILDING 4. 60"(l 525 MM)DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR STORE#: 8979 <br /> DEPARTMENT FOR FURTHER REVIEW.PLANS MUST CLEARLY SHOW ALL EXISTING NON CONFORMING ACCESS. <br /> u! CONDITIONS AFFECTED BY THE REMODEL(INCLUDING SITE PLAN,FLOOR PLANS,DETAILS,ETC)AND PROJECT#: 20927-065 <br /> chi PROPOSED MODIFICATIONS OF THE DEFICIENCIES TO MEET CURRENT ACCESSIBILITY PROVISIONS. 5. POSTRANSACTIONPLANE,CONDIMENTCARTTOPANDHAND-OFF B.Q.H. PLUMBING FIXTURE CALL <br /> o PLANE ARE 34 INCHES(860 MM)ABOVE THE FINISHED FLOOR FOR CASEWORK CONCEPT: <br /> a G. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY WHEELCHAIR ACCESSIBILITY. ISSUE DATE: 01/30/20 <br /> rn EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF SECTION 1011 AND AS NOTED BELOW: PLUMBING FIXTURES: OCCUPANCY LOAD CALCULATION DESIGN MANAGER: Tina Marinic <br /> 6. DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPENABLE FROM <br /> o CAFE SEATING LEES AP: N/A <br /> 1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. THE INSIDE W/O ANY USE OF A KEY OR ANY SPECIAL KNOWLEDGE INT.SEATING: 276 S.F./30= 9.3 <br /> OR EFFORT. EXT.SEATING: 209 S.F./30= 7 PROGRAM MANAGER: Tina Marinic <br /> 2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF REMAINING: 1223 S.F./200= 6.1 CHECKED BY: <br /> 'p EGRESS TRAVEL. 7. PROVIDE TACTILE"EXIT"SIGNAGE. AREAS NOT CALCULATED IN OCCUPANCY TOTAL: = 23 <br /> C;_ LOAD:437 S.F. Revision Schedule <br /> 3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT(30.5 M)OR THE LISTED VIEWING 8. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN. PER SECTION 422.2 EXCEPTION(3): <br /> j DISTANCE FOR THE SIGN,WHICHEVER IS LESS,FROM THE NEAREST VISIBLE EXIT SIGN. �:i i 'Inbusinessand mercantile occupancies with a total occupant load of 50 or less Rev Date By Description <br /> PATIO SEATING:209 S.F. including customers and employees,one toilet facility,designed for use by no more <br /> H. WQUIREDYOPERATED LOCKING DEVICES ARE USED,POSTASIGN ON OR ADJACENT DOOR TO <br /> _ than one person at a time,shall be permitted for use by both sexes. <br /> ..:.. ..:.....:.. <br /> REQUIRED MAIN EXIT DOOR WITH 1 INCH(25 MM)LETTERING STATING THAT"THIS DOOR TO REMAIN <br /> UNLOCKED WHEN BUILDING IS OCCUPIED".(1008.1.9.3) REQUIRED PROVIDED <br /> I. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A WATER CLOSETS: <br /> KEY,SPECIAL KNOWLEDGE OR EFFORT. DOOR HANDLES,PULLS,LATCHES,LOCKS AND OTHER PATH OF TRAVEL:205 S.F. MALE 1:1-50 1 1 <br /> OPERATING DEVICES SHALL BE INSTALLED 34 INCHES(860 MM)TO 48 INCHES(1220 MM)ABOVE FEMALE 1:1-25 1 1 SHEET TITLE: <br /> FINISHED FLOOR.MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. LAVATORIES: <br /> d THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. MALE 1:1-150 1 1 LIFE ACCESSIBILITY <br /> n (1008.1.9) FEMLAE 1:1-150 1 1 PLAN <br /> r <br /> SCALE:AS SHOWN <br /> O SHEET NUMBER: <br /> N <br /> M 01 <br />