My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_1990-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:22:05 AM
Creation date
4/27/2020 12:23:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2001
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_1990-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />• <br />& <br />0 0 <br />Dimensions and tolerances <br />Pipe dimensions <br />Workmanship <br />The pipe and fittings shall be free from all defects including delaminations, <br />Pipe shall be manufactured to steel pipe outside diameters for all sizes. Pipe <br />indentations, pinholes, foreign inclusions, bubbles and resin -starved areas <br />outside diameter tolerances shall not exceed ± 1 percent. <br />which, due to their nature, degree or extent, detrimentally affect the strength <br />Wall thickness <br />0 0 <br />and serviceability of pipe or fittings. The pipe and fittings shall be as <br />The total wall thickness of pipe furnished under this specification shall not at <br />uniform as commercially practicable in color, opacity, density and other <br />any point be greater than 120 percent nor less than 871/2 percent of the <br />physical properties. <br />nominal thickness. <br />Fittings dimensions <br />Testing <br />Proof testing <br />All fittings supplied under this specification shall have face-to-face dimensions <br />Fittings shall be hydrostatically tested according to UL specifications by the <br />and laying lengths as specified in the manufacturer's literature. <br />manufacturer to rated pressure prior to shipment for signs of leakage or <br />porosity. <br />Physical and mechanical <br />ASTM classification <br />Quality control testing <br />property requirements <br />Pipe shall conform to ASTM D2310 standard classification RTRP-11CZ and <br />A sample of pipe shall be tested at a frequency specified by UL to determine <br />ASTM D2996 specification designation RTRP-11 CZ 5430. <br />conformance of the materials to the short-term circumferential stress <br />requirement tabulated above. <br />Minimum ASTM <br />Marking <br />Each component shall be marked to show the following: <br />Property Units Value* Method <br />Underwriters' Laboratories listing mark <br />Tensile strength <br />Manufacturer's name <br />Longitudinal 103 psi D2105 <br />Maximum pressure rating <br />224.5 <br />Circumferential 103 psi 65.0 D1599 <br />MPa 448 <br />Important notice <br />This literature and the information and recommendations it contains are <br />Tensile modulus <br />based on data reasonably believed to be reliable. However, such factors as <br />Longitudinal 106 psi <br />variations in environment, application or installation, changes in operating <br />19.3 D2105 <br />Circumferential 106 GPa psi 4.0 — <br />procedures, or extrapolation of data may cause different results. Ameron <br />GPa 27.6 <br />makes no representation or warranty, express or implied, including warranties <br />Compressive strength <br />of merchantability or fitness for purpose, as to the accuracy, adequacy or <br />Longitudinal 103 psi 32.5 D695 <br />completeness of the recommendations or information contained herein. <br />MPa 224 <br />Ameron assumes no liability whatsoever in connection with this literature <br />Compressive modulus <br />or the information or recommendations it contains. <br />Longitudinal 106 psi 2.8 D695 <br />GPa 12.3 <br />Written comments regarding this document are invited. Please write <br />Long-term hydrostatic design basis 3 <br />Static 10 psi 31.5 D2992(B) <br />Engineering Manager, Ameron Fiberglass Pipe Division. <br />MPa 217 <br />Thermal expansion <br />Linear 10-6in/in/°F 9.0* * D696 <br />10-6mm/mm/0C 16.2* * <br />Stiffness factor* * * D2412 <br />(in) (mm) (lb • in3/in2) (N • m) <br />2 50 45 5.1 <br />3 80 65 7.3 <br />4 100 55 6.2 <br />6 150 250 28 <br />* Based on structural wall thickness. <br />* * Maximum value. <br />* * * At 5% diametric deflection and room temperature. <br />Joining methods <br />Tapered bell x spigot adhesive joints <br />Pipe and fittings shall be joined by means of a matching tapered adhesive <br />joint. Adhesive for joining components shall be compatible with all intended <br />fluids. Adhesive system shall be used according to manufacturer's <br />recommendations. <br />Adapters and crossovers <br />The following adapters and crossovers shall be provided as required: <br />Threaded adapter: bell x male <br />Threaded adapter: bellx female <br />Threaded adapter: spigot x male <br />Threaded adapter: spigot x female <br />Flanges <br />Flanges shall be two piece (Van Stone) type provided with raised grooves on <br />• • <br />the sealing face. Fiberglass reinforced stub ends are to be adhesive bonded to <br />the pipe or fitting. <br />