0 0 <br />PIPING SUMP CONTAINMENT TESTING <br />Test Method By: <br />Test Method Uses: <br />Measuring Equipment Used: <br />Manufacturer • Industry Standard <br />Pressure vacuum <br />Level Change Indicator <br />Professional Engr. Other (see below) <br />• Hydrostatic Other (see below) <br />(Caldwell System 2001 / Watton Engineering) <br />Description <br />Tank #1 <br />Tank #2 <br />Tank #3 <br />Is system programmed for fail-safe operation? <br />Sump material <br />FRP <br />FRP <br />FRP <br />No <br />No <br />Sump diameter (inches) <br />48" <br />48" <br />48" <br />Yes <br />Was sensor property replaced after testing? <br />Sump depth (inches) <br />W. <br />58" <br />56" <br />Tank product <br />Gasoline - 87 <br />Gasoline - 89 <br />Gasoline - 91 <br />None <br />Depth of water level from tank top (inches) <br />Heigh from tank top to highest <br />piping penetration <br />15" <br />18" <br />20" <br />1:00 PM <br />12:55 PM <br />Height from tank top to lowest <br />electrical penetration <br />6" <br />5" <br />10" <br />12:45 PM <br />Test duration (hr:min) <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />0.000 <br />0.000 <br />T of sum penetration <br />Pass/Fail threshold (0.005 inches /'r4 Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Condition of sump prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor property replaced after testing? <br />Yes <br />Yes <br />Yes <br />fitti s <br />None <br />None <br />None <br />Condition of sump prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor property replaced after testing? <br />Yes <br />Yes <br />Yes <br />Wait time for water level to stabilize (hrmin) <br />0:05 <br />0:07 <br />0:08 <br />Depth of water level from tank top (inches) <br />17" <br />20" <br />22" <br />Test start time <br />1:00 PM <br />12:55 PM <br />12:15 PM <br />Test end time <br />130 PM <br />1:25 PM <br />12:45 PM <br />Test duration (hr:min) <br />030 <br />030 <br />030 <br />Change in water level (t 0.000 inches) <br />0.000 <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches /'r4 Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />2003 Watton Engineering, Inc. <br />