Laserfiche WebLink
. 20 January 2000 <br /> AGE-NC Project No 95-0173 <br /> Page 7 of 14 <br /> Six additional SVE wells and twelve additional IAS wells will be installed at the site to supplement <br /> remediation efforts of the petroleum hydrocarbon impacted area at the site Proposed SVE well <br /> locations are illustrated in Figure 3, proposed IAS well locations are illustrated in Figure 3 <br /> Based on an estimated SVE radius of influence of 30 feet (Corrective Action Plan, dated 01 June <br /> 1999), AGE proposes installation of six SVE wells in the following locations <br /> • approximately 30 feet west of MW-2, <br /> • approximately 30 feet east of MW-2, <br /> • approximately 40 feet west of MW-1, <br /> • approximately 35 feet east of MW-1, and <br /> • approximately 50 feet west of MW-3 <br /> • approximately 45 feet west of VW-2 <br /> Based on an estimated IAS influence (Corrective Action Plan, dated 05 May 1998) and the existing <br /> and proposed SVE well locations, AGE proposes installation of twelve IAS wells in the following <br /> locations <br /> • approximately 10 feet west of MW-2, <br /> • approximately 45 feet east of MW-2, <br /> • approximately 20 feet southeast of MW-2, <br /> • approximately 30 feet west of VW-1, <br /> • approximately 30 feet south of VW-1, <br /> • approximately 20 feet south of VW-2, <br /> • approximately 25 feet northeast of VW-2, <br /> • approximately 30 feet west of MW-3 <br /> • approximately 25 feet southwest of MW-3, <br /> • approximately 15 feet east of MW-3 <br /> • approximately 25 feet southeast of MW-3, and <br /> • approximately 35 feet east to southeast of MW-3 <br /> • Advanced GeoEnvironmental,Inc <br />