My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005852
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
935
>
3500 - Local Oversight Program
>
PR0545617
>
ARCHIVED REPORTS_XR0005852
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2020 2:09:04 PM
Creation date
4/28/2020 1:26:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005852
RECORD_ID
PR0545617
PE
3528
FACILITY_ID
FA0005557
FACILITY_NAME
RIPON FARM SERVICE
STREET_NUMBER
935
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102007/2011
CURRENT_STATUS
02
SITE_LOCATION
935 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> 11 <br /> ' Site Background Information: Ripon Farm Service <br /> Page 5 of.7 <br /> detected at maximum concentrations in samples collected from well VW-1 of 720 µg/l and <br /> 800 µg/l, respectively. Low concentrations (less then 3 µg/1) or lack of detectable BTEX <br /> ' compounds have been encountered in ground water samples from wells MW-1 and MW-3 <br /> through MW-8. <br /> • DIPE has been detected in ground water samples from wells MW-3, MW-4 and MW-8 at <br /> concentrations as high as 17 µg/l. TBA has been detected in samples from wells MW-1, <br /> MW-2, MW-3, MW-4, MW-8 and soil vapor wells VW-1 and VW-2 at concentrations.as <br /> high as 120 µg/l, respectively. MTBE has been detected in samples from wells MW-1 and <br /> MW-3 at concentrations as high as 6.7 µg11.ETBE and TAME have not been detected in any <br /> of the wells sampled. <br /> TPH-d concentrations exceeded TPH-g concentrations in the samples containing both analytes. <br /> ' Impacted soil was present below the ground water table at the time remediation began, due to <br /> historically lower ground water elevations at the site during which time a portion of the unauthorized <br /> hydrocarbon release occurred. The former UST area was impacted by diesel fuel compounds, but <br /> ' also is impacted by significant concentrations of gasoline fuel compounds. <br /> The volume of soil addressed by the remediation system was estimated to be 645 cubic meters based <br /> ,. on the limited lateral extent of the vadose zone contamination and a depth to ground water of 20 . <br /> feet bsg. The generalized mass of vadose-adsorbed TPH-g was approximately 65.2 lbs or 29.58 kg <br /> and generalized mass of adsorbed TPH-d was approximately 77.16 lbs or 35 kg. <br /> 1 ' <br /> The total volume of impacted soil addressed by the remediation system was estimated to be 1,240 <br /> ' cubic meters,from the base of the former UST excavation to the depth of 30 feet bsg.The total mass <br /> of adsorbed TPH-g was approximately 123.5 lbs or 56.8 kg and mass of total adsorbed TPH-d was <br /> approximately 150 lbs or 68.2 kg. <br /> ' Hydrocarbon-impacted ground water in the former UST area has higher average TPH-g:TPH-d <br /> rations(0.702- 1.852)indicating a greater contribution to ground water of TPH-gin the former UST <br /> ' area. <br /> 1 SOIL AND GROUND WATER REMEDIATION <br /> On 25, 26 and 27 April 2000, four air=sparge (IAS)pilot borings and eleven soil vapor extraction <br /> ' (SVE)pilot borings were advanced at the site.Borings IAS 1 through IAS4 were completed as two- <br /> inch diameter air sparging wells,drilled to a total depth of 25 feet bsg with a 5-foot screen interval. <br /> Two vertical zones of remediation wells were installed as follows: borings VW-3A, VW-8 and <br /> ' VW-9A were completed as vapor extraction wells, drilled to a total depth of approximately 13 feet <br /> bsg and completed with a 5-foot screen intervals; borings VW-3B,VW-4, VW-5, VW-6, VW-7, <br /> ' Advanced GeoEnviron mental,Inc. <br /> 1 . <br />
The URL can be used to link to this page
Your browser does not support the video tag.