My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005703
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
11396
>
3500 - Local Oversight Program
>
PR0545624
>
ARCHIVED REPORTS_XR0005703
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:32 PM
Creation date
4/29/2020 1:14:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005703
RECORD_ID
PR0545624
PE
3528
FACILITY_ID
FA0003786
FACILITY_NAME
T&T TRUCKING INC
STREET_NUMBER
11396
Direction
N
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05926010
CURRENT_STATUS
02
SITE_LOCATION
11396 N HWY 99 RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr Michael Infurna <br /> July 21, 2006 <br /> Page 4 <br /> Results <br /> Drilling Drilling, sampling, and installation of the wells were completed following <br /> the procedures specified in the Work Plan for Soil Vapor Extraction Well <br /> Installation and Soil Vapor Extraction and Air Sparge Pilot Tests (Brown and <br /> Caldwell,2005) The lithology of the screened interval was silty sand to sand <br /> consistent with the geologic cross sections provided in the Subsurface Investigation <br /> Results and Site Conceptual Model (Brown and Caldwell,2004) The hthologic <br /> boring logs for VEW-1 and VEW-2 are provided in Attachment A <br /> SVE-Only The field-measured differential pressures and the resulting calculated <br /> extraction well flow-rates are presented in Table 2 Three flow rates were tested <br /> during the SVE pilot test As indicated in Table 2, soil vapor extraction flow rates <br /> ranged from 75 3-standard cubic feet per nunute (scfm) at the start of the test to <br /> 160 6 scfm for the last step of the test,with an average flow rate of 100 scfm <br /> The applied vacuum ranged from 11-inches of water (in H2O) to 52 in H2O with <br /> an average of 23 in HBO Total VOC values in the effluent from VEW-1 <br /> decreased from a high of 11,060-parts-per-million (ppm) after 15 minutes of <br /> operation to 4,420 ppm at the end of the 7 5-hour SVE only portion of the pilot <br /> test The field-measured flow rate and total VOC values for the SVE only portion <br /> of the pilot test are presented in Table 2 and shown on Figure 3 <br /> According to the USEPA Bioventing Principals and Practice,Volume 2 (Office of <br /> Research and Development, 1995), the radius of influence (ROI) of a soil-vapor <br /> extraction well is defined as the distance from the extraction well at which a <br /> vacuum of 01 in H2O occurs Vacuum observation measurements were collected <br /> from VEW-2 during the SVE only portion of the pilot test (Table 2) At an <br /> applied vacuum of 52-inches H2O at VEW-1,vacuum pressures ranging from 4 5 <br /> to 4 75-inches HBO were observed at VEW-2 Using a value of 4 6-inches H2O, <br /> an estimated radius of influence would be approximately 22-feet (Figure 4) <br /> AS-Only The initial breakthrough pressure for the AS test was 6 5-pounds psi at <br /> 5 cfm Following operation of the system for 1 hour and 15 minutes, the pressure <br /> dropped to 6 psi and the flow increased to 7 cfm After an initial increase of <br /> dissolved oxygen concentrations in surrounding monitoring wells MW-2,MW-3, <br /> and MW-4, as shown in Table 3, the concentrations decreased over the duration of <br /> the AS test Groundwater elevations in MW-2 and MW-4 fell less than 1-inch <br /> while the groundwater elevation in MW-3 dropped 8-inches over the duration of <br /> the AS test The resulting gradient and direction during the AS test ranged from <br /> 0 02 ft/ft to 0 004 ft/ft to the northeast (Figure 5) <br /> ]'\280(X)\128253 I&f Trucking',VF\Documents\tiV L Kcport amw doc <br />