ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL <br /> SECTION 260519 - LOW-VOLTAGE (600V OR LESS) ELECTRICAL POWER CONDUCTORS AND CABLES SECTION 260533 -RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260553 -IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 262726 -WIRING DEVICES <br /> 1.1 MATERIALS PART 1 - GENERAL 1.1 QUALITY ASSURANCE 1.1 PRODUCTS <br /> A. CONDUCTORS AND CABLES: A. COMPLY WITH ANSI A13.1 AND IEEE C2. A. RECEPTACLES: DUPLEX, 125 V, 20 A. <br /> 1. CONDUCTORS: COPPER. 1.1 MATERIALS 1. STRAIGHT BLADE: CONVENIENCE AND ISOLATED GROUND. <br /> 2. CONDUCTOR INSULATION: TYPE THHN/THWN-2, TYPE XHHW-2, TYPE USE AND A. METAL CONDUITS, TUBING, AND FITTINGS: 1.2 PRODUCTS 2. GFCI: FEED THROUGH. <br /> TYPE SO. 1. GRC. A. POWER AND CONTROL RACEWAY IDENTIFICATION:VINYL LABELS 3. TWIST-LOCKING TYPE WITH ISOLATED-GROUND TERMINAL. <br /> 3. MULTICONDUCTOR CABLE: METAL-CLAD CABLE, TYPE MC WITH GROUND WIRE. 2. EMT. B. PENDANT CORD-CONNECTOR DEVICES WITH EXTERNAL CABLE GRIP. <br /> 3. FMC: ZINC-COATED STEEL. B. POWER AND CONTROL CABLE IDENTIFICATION:VINYL LABELS C. CORD AND PLUG SETS: MATCH VOLTAGE AND CURRENT RATINGS AND NUMBER OF <br /> 1.2 CONDUCTOR MATERIAL APPLICATIONS 4. LFMC. CONDUCTORS TO REQUIREMENTS OF EQUIPMENT BEING CONNECTED. <br /> A. FEEDERS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG 5. FITTINGS: C. CONDUCTOR IDENTIFICATION: D. TOGGLE SWITCHES: 120/277 V, 20 A. <br /> AND LARGER. a. EMT: STEEL, SETSCREW OR COMPRESSION TYPE. SNAP-AROUND LABELS. 1. PILOT-LIGHT SWITCHES. <br /> B. BRANCH CIRCUITS: COPPER. SOLID FOR NO. 12 AWG AND SMALLER; STRANDED FOR b. EXPANSION FITTINGS. 2. KEY-OPERATED SWITCHES. <br /> NO. 10 AWG AND LARGER, EXCEPT VFC CABLE, WHICH SHALL BE EXTRA FLEXIBLE B. NONMETALLIC CONDUITS, TUBING, AND FITTINGS: D. FLOOR MARKING TAPE: 2-INCH- (50-MM-)WIDE PRESSURE-SENSITIVE VINYL TAPE. E. WALL-BOX DIMMERS: 02011 STARBUCKS COFFEE COMPANY <br /> STRANDED. 1. RNC. E. UNDERGROUND-LINE WARNING TAPE:PIGMENTED POLYOLEFIN 1. MODULAR, FULL-WAVE, SOLID-STATE UNITS WITH SLIDER CONTROL. <br /> 2. FITTINGS: MATCH CONDUIT. a. INCANDESCENT: SOFT TAP OR OTHER QUIET SWITCH; EMI/RFI STARBUCKS COFFEE <br /> 1.3 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING 3. SOLVENT CEMENTS AND ADHESIVE PRIMERS SHALL HAVE A VOC CONTENT OF F. WARNING LABELS AND SIGNS:SELF-ADHESIVE WARNING LABELS. FILTER TO ELIMINATE INTERFERENCE. <br /> METHODS 510 AND 550 G/L OR LESS, RESPECTIVELY. b. FLUORESCENT: TRIM POTENTIOMETER FOR LOW-END DIMMING. COMPANY <br /> A. SERVICE ENTRANCE: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. C. METAL WIREWAYS AND AUXILIARY GUTTERS: SHEET METAL WITH G. INSTRUCTION SIGNS:ENGRAVED. c. LED: COMPATIBLE WITH LED DRIVER OR LAMP. <br /> B. EXPOSED FEEDERS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. SCREW COVERS. F. WALL PLATES: 2401 UTAH AVENUE SOUTH <br /> C. FEEDERS CONCEALED IN CEILINGS, WALLS, PARTITIONS,AND CRAWLSPACES: D. SURFACE METAL RACEWAYS: METAL, GALVANIZED STEEL, WITH SNAP-ON COVERS. H. EQUIPMENT IDENTIFICATION LABELS:ENGRAVED, LAMINATED 1. MATERIAL FOR WORKROOM: <br /> METAL-CLAD CABLE. E. BOXES, ENCLOSURES, AND CABINETS: ACRYLIC OR MELAMINE PLASTIC. SATIN-FINISHED STAINLESS STEEL. SEATTLE, WASHINGTON 98134 <br /> D. FEEDERS CONCEALED IN CONCRETE, BELOW SLABS-ON-GRADE, AND UNDERGROUND: 1. METAL OUTLET AND DEVICE BOXES:FERROUS ALLOY 2. MATERIAL FOR BAR: (206) 318-1575 <br /> TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. 2. METAL FLOOR BOXES: CAST METAL OR SHEET METAL, FULLY END OF SECTION 260553 SATIN-FINISHED STAINLESS STEEL. <br /> E. EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN/THWN-2, ADJUSTABLE. 3. MATERIAL FOR CUSTOMER AREAS:THERMOPLASTIC WITH COLOR OPTION PER THESE DRAWINGS AND SPECIFICATIONS ARE <br /> SINGLE CONDUCTORS IN RACEWAY. 3. LUMINAIRE OUTLET BOXES: NONADJUSTABLE, DESIGNED FOR ATTACHMENT OF STARBUCKS. CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> F. BRANCH CIRCUITS CONCEALED IN CEILINGS, WALLS,AND PARTITIONS: TYPE LUMINAIRE WEIGHING 50 LB (23 KG). G. FLOOR SERVICE FITTINGS: MODULAR, (DUAL SERVICE IF NEEDED), WITH POWER PROPERTY OF STARBUCKS CORPORATION, <br /> THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. 4. SMALL SHEET METAL PULL AND JUNCTION BOXES. ELECTRICAL RECEPTACLE (AND VOICE AND DATA COMMUNICATION OUTLET IF NEEDED). WHICH IS THE OWNER OF THE COPYRIGHT IN THIS <br /> G. BRANCH CIRCUITS CONCEALED IN CONCRETE, BELOW SLABS-ON-GRADE, AND 5. CAST-METAL ACCESS, PULL, AND JUNCTION BOXES. 1. TYPE:FLUSH WORK. THEY SHALL NOT BE REPRODUCED(IN <br /> UNDERGROUND: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. 6. BOX EXTENSIONS. SECTION 260923 -LIGHTING CONTROL DEVICES 2. SERVICE PLATE:RECTANGULAR. WHOLE OR IN PART), SHARED WITH THIRD <br /> H. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS: TYPE SO, HARD 7. GANGABLE BOXES ARE PROHIBITED. 3. VOICE AND DATA COMMUNICATION OUTLET: BLANK COVER WITH BUSHED CABLE PARTIES OR USED IN ANY MANNER ON OTHER <br /> SERVICE CORD WITH STAINLESS-STEEL, WIRE-MESH, STRAIN RELIEF DEVICE AT 8. HINGED-COVER ENCLOSURES: METAL. 1.1 PRODUCTS OPENING. PROJECTS OR EXTENSIONS TO THIS PROJECT <br /> TERMINATIONS TO SUIT APPLICATION. 9. CABINETS: GALVANIZED STEEL. A. TIME SWITCHES:ELECTRONIC, PROGRAMMABLE UNITS, WITH SINGLE CHANNEL; H. POKE-THROUGH ASSEMBLIES: BELOW-FLOOR JUNCTION BOX WITH MULTICHANNELED, WITHOUT THE PRIOR WRITTEN CONSENT OF <br /> F. HANDHOLES AND BOXES FOR EXTERIOR UNDERGROUND WIRING: POLYMER ASTRONOMIC TIME, SEVEN-DAY THROUGH-FLOOR RACEWAY/FIRESTOP AND DETACHABLE FLOOR SERVICE-OUTLET STARBUCKS CORPORATION. THESE DRAWINGS <br /> 1.4 FIELD QUALITY CONTROL CONCRETE WITH POLYMER-CONCRETE FRAME AND COVER, PROTOTYPE TESTED PROGRAMMABLE WITH MINIMUM 8 ON/OFF SET POINTS PER 24 HOUR ASSEMBLY. AND SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> A. TESTING: BY CONTRACTOR. FOR COMPLIANCE WITH SCTE 77. SCHEDULE. 1. SERVICE-OUTLET ASSEMBLY: SURFACE TYPE. DESIGN INTENT FOR A PROTOTYPICAL <br /> 1. CONFIGURATION: INTEGRAL CLOSED BOTTOM. B. OUTDOOR PHOTOELECTRIC SWITCHES: SOLID STATE, WITH DRY CONTACTS, 2. SIZE:4 INCHES (100 MM). STARBUCKS STORE(WHICH IS SUBJECT TO <br /> END OF SECTION 260519 2. WEATHERPROOF COVER. 15-SECOND TIME DELAY, AND METAL-OXIDE VARISTOR SURGE PROTECTION. I. MULTIOUTLET ASSEMBLIES: MANUFACTURED AND LISTED METAL RACEWAYS. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> ACTUAL SITE CONDITIONS. NEITHER PARTY SHALL <br /> 3. COVER LEGEND:"ELECTRIC." C. DAYLIGHT-HARVESTING SWITCHING CONTROLS: CEILING MOUNTED WITH J. SERVICE POLES: TO EXTEND POWER AND VOICE AND DATA COMMUNICATION <br /> HAVE ANY OBLIGATION NOR LIABILITY TO THE <br /> ADJUSTABLE TIME DELAY AND SET-POINTS. WIRING FROM DISTRIBUTION WIRING IN CEILING TO DEVICES OR OUTLETS IN POLE <br /> OTHER(EXCEPT STATED ABOVE) UNTIL A <br /> 1.2 RACEWAY APPLICATION D. INDOOR OCCUPANCY SENSORS:DUAL-TECHNOLOGY TYPE, NEAR FLOOR. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> A. OUTDOORS: WITH SEPARATE, EXTERNALLY MOUNTED RELAY UNIT. 1. FINISH: PAINTED. BOTH PARTIES. <br /> ELECTRICAL 1. EXPOSED: GRC. E. SWITCH BOX-MOUNTED OCCUPANCY SENSORS. 2. POWER RECEPTACLES: TWO, DUPLEX, 20 A. <br /> 2. CONCEALED, ABOVEGROUND: RNC, TYPE EPC-40-PVC. F. LIGHTING CONTACTORS: ELECTRICALLY OPERATED AND 3. VOICE AND DATA COMMUNICATION OUTLETS:BLANK INSERT <br /> 3. UNDERGROUND: RNC, TYPE EPC-40-PVC, DIRECT BURIED. ELECTRICALLY HELD, WITH NONFUSED DISCONNECT IN ARCHITECT OF RECORD <br /> SECTION 260526 -GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 4. CONNECTION TO VIBRATING EQUIPMENT: LFMC. NEMA 250 ENCLOSURE. PROVIDE WITH CONTROL AND PILOT DEVICES AS K. FINISHES: a' <br /> 1.1 QUALITY ASSURANCE 5. BOXES AND ENCLOSURES, ABOVEGROUND: TYPE 3R OR TYPE 4. INDICATED IN PLANS. 1. CONNECTED TO NORMAL POWER SYSTEM:WHITE <br /> U U QJ _ • <br /> A. QUALITY STANDARD FOR GROUNDING AND BONDING MATERIALS AND B. INDOORS: G. EMERGENCY SHUNT RELAY: NORMALLY CLOSED, ELECTRICALLY HELD, <br /> EQUIPMENT: UL 467. 1. EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: GRC. ARRANGED FOR WIRING IN PARALLEL WITH AUTOMATIC 2. CONNECTED TO EMERGENCY POWER SYSTEM: RED " <br /> 2. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT. SWITCHING CONTACTS. 3. ISOLATED-GROUND RECEPTACLES: AS SPECIFIED ABOVE, WITH cn <br /> 1.2 PRODUCTS 3. CONCEALED: EMT. H. CONTROL CABLES: ORANGE TRIANGLE ON FACE. <br /> A. INSULATED CONDUCTORS: COPPER WIRE OR CABLE. 4. CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT LFMC IN DAMP OR WET 1. POWER CABLES: NOT SMALLER THAN NO. 12 AWG. <br /> B. BARE COPPER CONDUCTORS: LOCATIONS. 2. CLASSES 2 AND 3 CONTROL CABLES: STRANDED-COPPER CONDUCTORS, NOT END OF SECTION 262726 m c g a r c h i t e c u r e <br /> 1. SOLID CONDUCTORS. 5. DAMP OR WET LOCATIONS: GRC. SMALLER THAN NO. 18 AWG. 111 Pacifica, Suite 280, Irvine,CA 92618 <br /> 2. STRANDED CONDUCTORS. 6. BOXES AND ENCLOSURES: TYPE 1, EXCEPT TYPE 4 STAINLESS STEEL 3. CLASS 1 CONTROL CABLES: STRANDED-COPPER CONDUCTORS, NOT SMALLER P: 949.553.1117 F:949.474.7056 <br /> 3. TINNED CONDUCTORS. IN DAMP OR WET <br /> 4. STRANDED BONDING CONDUCTORS. C. MINIMUM RACEWAY S ZOE: 3/41--INCH TRADE SIZE. THAN NO. 14 AWG. ELECTRICAL <br /> 5. COPPER TAPE BRAIDED BONDING JUMPERS. D. RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND END OF SECTION 260923 <br /> 6. TINNED-COPPER BRAIDED BONDING JUMPERS. LOCATION. SECTION 262816 -ENCLOSED SWITCHES AND CIRCUIT BREAKERS ACIES <br /> C. CONNECTORS: BOLTED AND EXOTHERMIC-WELDED TYPE. 1. RIGID AND INTERMEDIATE STEEL CONDUIT: THREADED RIGID STEEL CONDUIT rr�oQRQFESS/pNglt�t <br /> 1.1 PRODUCTS <br /> D. GROUNDING ELECTRODES: FITTINGS. A. FUSIBLE SWITCHES: ti✓rr'L�` `SLPV Z.C !F it <br /> 1. GROUND RODS: COPPER-CLAD STEEL, SECTIONAL TYPE WITH GROUND WELL 2. PVC EXTERNALLY COATED, RIGID STEEL CONDUITS: FITTINGS LISTED FOR ENGINEERING 9 <br /> AND COVER. USE WITH THIS TYPE OF CONDUIT. ELECTRICAL AND NEMA KS 11, NEMA 3R TYPE GD1. GENERAL DUTY, SINGLE W [240-V] [600V]AC, 800 A AND SMALLER: UL 98 <br /> 3371 Olcott Street �l <br /> 3. EMT: COMPRESSION FITTINGS. Santa Clara,CA 95054 l 15130 A 1 <br /> SECTION 262416- PANELBOARDS 2. ACCESSORIES: <br /> 1.3 FIELD QUALITY CONTROL 4. FLEXIBLE CONDUIT: FITTINGS LISTED FOR USE WITH FLEXIBLE CONDUIT. <br /> A. GROUND RESISTANCE TESTING: BY CONTRACTOR-ENGAGED AGENCY. 1.1 QUALITY ASSURANCE a. EQUIPMENT GROUND KIT. ph:(408)522-5255 <br /> tTt *rrr <br /> END OF SECTION 260533 A. MANUFACTURER QUALIFICATIONS: ISO 9001 OR 9002 CERTIFIED. b. NEUTRAL KIT. fx:(408)522 5260 222J1 4FCTRc. �GP <br /> END OF SECTION 260526 d. CLASS RDFUSE KIT.GROUND KIT. Co yrightinfo@acic 2019 ttiii OF CA�vFO`��r' <br /> 1.2 PRODUCTS pY g O <br /> A. GENERAL REQUIREMENTS FOR PANELBOARDS: e. AUXILIARY CONTACT KIT. <br /> 1. CONSTRUCTED TO WITHSTAND SEISMIC FORCES. f. HOOKSTICK HANDLE. <br /> ELECTRICAL 2. ENCLOSURES: SURFACE MOUNTED. h. SERVICE-RATED SWITCHES. <br /> ELECTRICAL a. FRONT: HINGED COVER WITH KEY LOCK. i. ACCESSORY CONTROL POWER. <br /> SECTION 260536 -CABLE TRAYS FOR ELECTRICAL SYSTEMS b. OPTIONAL ENCLOSURE FEATURES:SKIRT FOR SURFACE-MOUNTED B. NONFUSIBLE SWITCHES: <br /> DIRECTORY <br /> 1.1 CABLE TRAY TYPES C. DIRECTTORY CCARD. <br /> SECTION 260529 -HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PANELBOARDS. 1. GENERAL DUTY, SINGLE THROW, [240-V] [600V]AC, 600 A AND SMALLER: UL 98 <br /> A <br /> 1.1 PERFORMANCE REQUIREMENTS A. LADDER. 3. INCOMING MAINS:CONVERTIBLE BETWEEN TOP AND BOTTOM AND NEMA KS 1, NEMA 3R TYPE GD. <br /> CCESSORIES:A <br /> A. DESIGN SUPPORTS FOR MULTIPLE RACEWAYS CAPABLE OF SUPPORTING B. SINGLE RAIL. 4. PHASE, NEUTRAL AND GROUND BUSES: TIN-PLATED COPPER. 2. ACCESSORIES: <br /> GROUND KIT. <br /> COMBINED WEIGHT OF SUPPORTED SYSTEMS AND ITS CONTENTS. C. TROUGH. 5. CONDUCTOR CONNECTORS: a.b. NEUTRAL KIT. <br /> B. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING a. MATERIAL: TIN-PLATED COPPER. c. ISOLATED GROUND KIT. <br /> WEIGHT OF SUPPORTED EQUIPMENT AND CONNECTED SYSTEMS AND 1.2 MATERIALS b. MAIN AND NEUTRAL LUGS: MECHANICAL TYPE. RY CONTACT KIT. <br /> COMPONENTS. A. CABLE TRAYS, FITTINGS, AND ACCESSORIES: STEEL. c. FEED-THROUGH LUGS: MECHANICAL TYPE. e. Hc. AUXILIAUXILIA CK HANDLE. Q <br /> 1. FACTORY-STANDARD PRIMER; WITH CHROMIUM-ZINC-PLATED HARDWARE. 6. PERCENTAGE OF FUTURE SPACE CAPACITY:FIFTEEN f. LUGS: MECHANICAL. 0 <br /> 1.2 PRODUCTS 2. MILL GALVANIZED BEFORE FABRICATION; WITH PERCENT. C. MOLDED-CASE CIRCUIT BREAKERS:g. ACCESSORY CONTROL POWER. V J (V <br /> A. SUPPORT, ANCHORAGE, AND ATTACHMENT COMPONENTS: GALVANIZED HARDWARE. 7. SERVICE EQUIPMENT LABEL FOR PANELBOARDS INCORPORATING ONE OR MORE �+, <br /> 1. STEEL SLOTTED SUPPORT SYSTEMS WITH 3. ELECTROGALVANIZED BEFORE FABRICATION; WITH GALVANIZED HARDWARE. MAIN SERVICE DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. M <br /> Lo <br /> METALLIC COATINGS. 4. HOT-DIP GALVANIZED AFTER FABRICATION; WITH B. PANELBOARD OR LOAD CENTER SHORT-CIRCUIT CURRENT RATING: FULLY RATED THERMAL-MAGNETIC TYPE.2. ADJUSTABLE INSTANTANEOUS-TRIP TYPE. W LLJ m <br /> 2. NONMETALLIC SLOTTED SUPPORT SYSTEMS. CHROMIUM-ZINC-PLATED HARDWARE. TO INTERRUPT SYMMETRICAL SHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. 3. ELECTRONIC-TRIP TYPE. z Q <br /> 3. RACEWAY AND CABLE SUPPORTS. 5. POWDER-COAT ENAMEL PAINT; WITH CHROMIUM-ZINC-PLATED LISTED SERIES RATED SYSTEM MAY BE USED IF APPROVED BY EOR TO LIMIT FAULT 4. CURRENT-LIMITING TYPE. Uj Q U <br /> 4. STEEL AND MALLEABLE-IRON CONDUIT AND CABLE HANGERS, CLAMPS, AND HARDWARE. TO BELOW 22K AIC FOR GFI BREAKERS. 5. INTEGRALLY FUSED TYPE. � (n J <br /> 6. GFCI TYPE. <br /> ASSOCIATED ACCESSORIES. 6. BLACK OXIDE FINISH FOR SUPPORT ACCESSORIES AND MISCELLANEOUS 1. MAINS: LUGS ONLY. ` 6 W <br /> 5. SUPPORT FOR NON-ARMORED CONDUCTORS AND CABLES IN VERTICAL HARDWARE. 2. BRANCH OVERCURRENT PROTECTIVE DEVICES FOR CIRCUIT-BREAKER FRAME LLI 0 z <br /> 7. GFEP TYPE. <br /> CONDUIT RISERS. 7. BLACK. SIZES LARGER THAN 125 A: BOLT-ON CIRCUIT BREAKERS. 8. FEATURES AND ACCESSORIES: 2 _ 0 U) O <br /> 6. STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND RESTRAINTS. B. CABLE TRAYS, FITTINGS, AND ACCESSORIES: ALUMINUM; WITH STAINLESS-STEELQ 0 <br /> C. LIGHTING AND APPLIANCE BRANCH-CIRCUIT PANELBOARDS: a. LUGS: MECHANICAL. z 1 Q Uj <br /> 7. MOUNTING, ANCHORING, AND ATTACHMENT COMPONENTS: HARDWARE. <br /> a. POWDER-ACTUATED FASTENERS. C. CABLE TRAY ACCESSORIES: 1. MAINS: LUGS ONLY. b. TYPE SWD 1--FOR SWITCHING FLUORESCENT LIGHTING LOADS. `f 3 <br /> 2. BRANCH OVERCURRENT PROTECTIVE DEVICES: PLUG-IN CIRCUIT-BREAKER c. TYPE HID FOR FEEDING FLUORESCENT AND HIGH-INTENSITY DISCHARGE 0 <br /> b. MECHANICAL-EXPANSION ANCHORS. 1. COVERS:LOUVERED TYPE. TYPE. LIGHTING CIRCUITS. W W U <br /> c. CONCRETE INSERTS. 2. BARRIER STRIPS. 3. DOORS: CONCEALED HINGE. d. GROUND-FAULT PROTECTION: INTEGRALLY MOUNTED, SELF-POWERED TYPE. __3O <br /> d. CLAMPS FOR ATTACHMENT TO STEEL STRUCTURAL ELEMENTS. 3. CABLE TRAY SUPPORTS AND CONNECTORS. D. LOAD CENTERS: 0 Q 0 <br /> e. ALL STEEL, SPRINGHEAD TOGGLE BOLTS. D. WARNING SIGNS: 1-1/2-INCH- (40-MM-) HIGH, BLACK LETTERS ON YELLOW1 � 5 � <br /> . MAINS: LUGS ONLY. e. SHUNT TRIP. G <br /> f. THREADED HANGER RODS. BACKGROUND WITH LEGEND "WARNING! NOT TO BE USED AS WALKWAY, LADDER, OR 2. BRANCH CIRCUIT BREAKERS: PLUG-IN. f. UNDERVOLTAGE TRIP: 35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT <br /> B. FABRICATED METAL EQUIPMENT SUPPORT ASSEMBLIES: WELDED OR BOLTED SUPPORT FOR LADDERS OR PERSONNEL". 3. DOORS: CONCEALED HINGE. INTENTIONAL TIME DELAY. <br /> STEEL SHAPES. 4. CONDUCTOR CONNECTORS: MECHANICAL TYPE. g. AUXILIARY CONTACTS:TWO SPDT SWITCHES. STORE #: 13402 <br /> 1.3 SOURCE QUALITY CONTROL E. DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES: h. ALARM SWITCH: ONE NO CONTACT. <br /> END OF SECTION 260529 A. TESTED ACCORDING TO NEMA FG 1. 1. CIRCUIT BREAKERS:THERMAL-MAGNETIC TYPES. i. KEY INTERLOCK KIT. PROJECT #: 39714-051 <br /> END OF SECTION 260536 2. GFI CIRCUIT BREAKERS: RATED FOR PERSONNEL. j. ZONE-SELECTIVE INTERLOCKING: INTEGRAL WITH ELECTRONIC TRIP. CASEWORK CONCEPT: CORE <br /> 3. AFCI CIRCUIT BREAKERS: AS REQUIRED BY CODE. <br /> 4. OPTIONS AND TYPES AS NEEDED. k. ELECTRICAL OPERATOR. ISSUE DATE: <br /> F. IDENTIFICATION: I. ACCESSORY CONTROL POWER. PROGRAM MANAGER: M. DREBIKA <br /> 1. PANELBOARD LABELS: MANUFACTURER'S NAME AND TRADEMARK, VOLTAGE, D. MOLDED-CASE SWITCHES: STORE DESIGNER: S. BELVINS <br /> ELECTRICAL AMPERAGE, NUMBER OF PHASES, ARC FLASH HAZARD, AND NUMBER OF POLES 1. MCCB WITH FIXED, HIGH-SET INSTANTANEOUS TRIP ONLY, AND SHORT-CIRCUIT <br /> SHALL BE LOCATED ON THE INTERIOR OF THE PANELBOARD DOOR. WITHSTAND RATING EQUAL TO EQUIVALENT BREAKER FRAME SIZE LEED®AP: N/A <br /> SECTION 260544-SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING 2. BREAKER LABELS: FACEPLATE SHALL LIST CURRENT RATING, UL AND IEC INTERRUPTING RATING. CHECKED BY: <br /> 1.1 MATERIALS CERTIFICATION STANDARDS, AND AIC RATING. 2. FEATURES AND ACCESSORIES: <br /> 3. CIRCUIT DIRECTORY: DIRECTORY CARD INSIDE PANELBOARD DOOR, MOUNTED a. LUGS: MECHANICAL. ACIES PROJECT#: 190480 <br /> A. SLEEVES: IN METAL FRAME WITH TRANSPARENT PROTECTIVE COVER b. GROUND-FAULT PROTECTION: REMOTE-MOUNTED AND POWERED TYPE. ACIES DESIGNER BY: HT <br /> 1. SCHEDULE 40 STEEL PIPE. c. SHUNT TRIP. <br /> 2. CAST-IRON PIPE. G. ACCESSORIES: ACIES CHECKED BY: TG <br /> 1. ACCESSORY SET INCLUDING TOOLS. d. UNDERVOLTAGE TRIP: 35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT <br /> 3. GALVANIZED-STEEL SHEET FOR CONDUITS PENETRATING NON-FIRE-RATED 2. PORTABLE TEST SET: FOR TESTING FUNCTIONS OF SOLID-STATE TRIP DEVICES INTENTIONAL TIME DELAY. <br /> GYPSUM-BOARD ASSEMBLIES. WITHOUT REMOVING FROM PANELBOARD. e. AUXILIARY CONTACTS:TWO SPDT SWITCHES Revision Schedule <br /> 4. MOLDED-PE OR-PP PIPE. f. ALARM SWITCH: ONE NO CONTACT. <br /> 5. GALVANIZED-STEEL SHEET FOR RECTANGULAR OPENINGS. 1.3 FIELD QUALITY CONTROL g. KEY INTERLOCK KIT. Rev Date By Description <br /> B. SLEEVE-SEALS: A. TESTING: BY CONTRACTOR. h. ZONE-SELECTIVE INTERLOCKING: INTEGRAL WITH REMOTE GROUND-FAULT <br /> 1. EPDM RUBBER SEALING ELEMENTS. TRIP UNIT. <br /> 2. CARBON-STEEL PRESSURE PLATES. END OF SECTION 262416 i. ELECTRICAL OPERATOR. <br /> 3. CARBON-STEEL, WITH CORROSION-RESISTANT COATING, j. ACCESSORY CONTROL POWER. <br /> CONNECTING BOLTS AND NUTS. E. ENCLOSURES: <br /> DC.. SILICONE HYDRAULIC-CEMENT <br /> GROUT. ELECTRICAL 1. INDOOR, DRY AND CLEAN LOCATIONS: NEMA 250, TYPE 1. <br /> 2. OUTDOOR LOCATIONS: NEMA 250, TYPE 3R. <br /> 1. SINGLE-COMPONENT, SILICONE-BASED, NEUTRAL-CURING ELASTOMERIC SHEET TITLE: <br /> SEALANT. SECTION 262713 - ELECTRICITY METERING 1.2 FIELD QUALITY CONTROL <br /> 2. MULTICOMPONENT, SILICONE-BASED LIQUID ELASTOMERIC NONSHRINKING 1.1 EQUIPMENT FOR ELECTRICITY METERING BY UTILITY COMPANY A. TESTING: BY CONTRACTOR. ELECTRICAL OUTLINE <br /> FOAM. A. UTILITY-COMPANY-COMPLIANT CURRENT-TRANSFORMER CABINETS: COMPLY WITH <br /> 3. VOC CONTENT OF 250 G/L OR LESS. REQUIREMENTS OF ELECTRICAL-POWER UTILITY COMPANY. 1.3 ADJUSTING SPECIFICATIONS <br /> END OF SECTION 260544 B. METER SOCKETS: COMPLY WITH REQUIREMENTS OF ELECTRICAL-POWER UTILITY A. SET FIELD-ADJUSTABLE CIRCUIT-BREAKER TRIP RANGES. SCALE: AS SHOWN <br /> COMPANY. <br /> END OF SECTION 262816 <br /> END OF SECTION 262713 SHEET NUMBER: <br /> E-002 <br />