My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2020 12:14:14 PM
Creation date
5/1/2020 9:04:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN-PAGE 2 <br /> ,w <br /> MONITORING OF AREAS BENEATH DISPENSER(S)IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) M50 ; <br /> ® 1.CONIINUOUS ELECIRONIC MONITORING OF UNDER DISPENSER CONIAINMENT(UDC) <br /> PANEL MANUFACIURER: Veeder Root Msl MODEL#: IIS 350 Msz <br /> LEAK SENSOR MANUFACTURER: _ Veeder Root Ms' MODEL#(S): 794 380-. 2.3 Msn <br /> WILL DEIECIION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? �—® a.YES ❑ b NO M55 <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a YES ❑ b.NO M" <br /> WILL FAILURE/DISCONNECIION OF UDC MONITORING SYSTEM IRIGGER AUI'OMAIIC PUMP SHUIDOWN? ® a YES ❑ b NO Msr <br /> ❑ 2.MECHANICAL ASSEMBLY(e g,FLOAT AND CHAIN ASSEMBLY)IN UDC IRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: M38 MODEL#(S): M59 <br /> ❑ 3 VISUAL MONITORING DONE: ❑ a DAILY Elb WEEKLY(Requires agency approval) Mho <br /> ❑ 4 NO DISPENSERS <br /> M61 <br /> ❑ <br /> 99.OTHER(Specify) _.T _- <br /> - VxI, ENHANCED LEAK DETECTION ' <br /> ❑ I WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK Myo <br /> DETECIION(ELD)FOR THE UST(S)COVERED BY IHIS PLAN.PER 23 CCR§2644.1,ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> V A:� TRAMO <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) M80 <br /> I ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2 ® OPERATING MANUALS FOR ELECIRONIC MONITORING EQUIPMENT(Required)* <br /> 3 ® THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as of MM/DD/YY) <br /> 4 ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULAITONS <br /> 5 ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6 ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICAIION: ''HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> SIAIISIICAL INVENTORY RECONCILIATION' <br /> 7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS' <br /> Msr <br /> 99 ElOTHER(Specify): <br /> Personnel with USI monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed <br /> By 1/1/2005:.this facility will have a"Designated UST Operator who has passed the operator exam administered by the International Code Council(ICC). By July 1, <br /> 2005,and annually thereafter,the 'Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems This training <br /> will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility s best management practices <br /> The facility employee's role with regard to the leak detection equipment <br /> ➢ The facility employees role with regard to spills and overfills <br /> ➢ Whom to contact for emergencies and leak detection alarms <br /> For facility employees hired on or after July 1,2005,the initial training will be conducted within 30 days of the date of hire. <br /> _ CON'S/ADDITIONAL INFOIMA7€'XO [ <br /> Please use this section to include any additional UST system monitoring-related information(e g,additional information required by your local agency): Mss <br /> *Monitoring systems manual maintained by contracted,licensed pump and tank technicians.. <br /> Best Management Practices are maintained in the H,.S,.S.E..Retail Facility Programs Manual(Green Binder).. <br /> *Tank Overfill Protection I`ype: Ovf4i U Alarm,alarm visual and audible at tank fill point(s)and operates alarm <br /> trigger at 90%. } <br /> : ER +ONNESPONSI$TLIIE ': <br /> _:.. <br /> THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEFORMING MONITORING BP WEST'COASI'PRODUCTS <br /> LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT. ' <br /> XI. QWNER/OURATOR SIGNATURE <br /> r <br /> CERTIF TION tify rnfor motion provided herein is true and accurate to the best of my knowledge. <br /> REPRESENTING DATE: <br /> ❑Owner M90 M91 <br /> OWE RA SI <br /> G(f <br /> ? ®Operator <br /> O RIOPEMTOR NAME print): Msz OWNER/OPERA FOR TITL E: M93 <br /> ALFRED REALI DEALER <br /> 1 _ ; <br /> (Agency Use Only) Ihis plan has been reviewed and: /(? Approved ❑Approved With Conditions ❑Disapproved <br /> n� <br /> Loc �Q�/�GDate: -41 l <br /> 7 <br /> Comments/Special Conditions: — <br /> i <br /> Arco 9 06020,Belshire Environmental Services Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.