My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2008 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 4:03:53 PM
Creation date
5/4/2020 9:32:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2009
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
322
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
36" SHEET MATERIALS LIST CLIENT- <br /> 2'-6" ITEM BY DESCRIPTION MANUFACTURER <br /> OPENING FOR 1" WAYNEVAC10)/2" 1 '-3" <br /> VAPOR RECOVERY OUTLET EXISTING SINGLE AND DUAL PRODUCT DISPENSERS W/ EXISTING "GILBARCO" MODEL BH1 <br /> 53 N/A "BALANCE" VAPOR RECOVERY HOSES AND NOZZLES EXISTING TO REMAIN <br /> EXISTING TO REMAIN <br /> 81 G.C. W/ 1 FU'SIBLE LINK W/AUTBOLTVINSSTOALLATION KITT "OPW" MODEL NO. OPW-10BHMP-5830 <br /> ;N rn POSITION 82 G.C. VAPOR RECOVERY IMPACT VALVE (TOP ENTRY) "OPW" MODEL NO. 60 VSP-1001 <br /> B ARCO <br /> - ~ - UNDER DISPENSER SPILL CONTAINMENT SUMP FOR NARROW FRAME GILBARCO <br /> rr u <br /> "WESTERN FIBERGLASS" MODEL NO. P WEST COAST PRODUCTS,LLC <br /> POSITION p 88 G.C. GASOLINE DISPENSERS (SINGLE WALL FRP — 26" DEEP W/ ADJUSTABLE FRAME) <br /> Ln <br /> T m 'A' (CONTRACTOR TD PLUMB ALL FITTINGS) STABILIZER BARS AND SHEAR VALVE DM-1630D3 <br /> I I0 <br /> PLATES INCLUDED W/ STABILIZER ASSEMBLIES ALLIANCE MANAGER, AGENT FOR BP: <br /> un, <br /> f <br /> CV <br /> SPEAKER UNLLET BOX 10" 10" 131 G.C. 2" FLEXIBLE ENTRY BOOT "OPW" MODEL NO. EBF-0200 <br /> SPEAKER CONDUIT OPENING 1/2" (4) 13/16" x 1-7/16" <br /> SLOTS FOR ANCHOR BOLTS 132 G.C. 3" FLEXIBLE ENTRY BOOT "OPW" MODEL NO. EBF-0300 <br /> A-A EXISTING GILBARCO BH 1 MOUNTING DIAGRAM 01i3 <br /> SCALE: 1"=1'--•0" G.C. CONDUIT ENTRY BOOT "DPW" MODEL NO. EBF-0751 <br /> 142 G.C. 2" (PRIMARY) FIBERGLASS PIPE, 22'-25' LENGTH & GLUE KITS "SMITH FIBERCAST" MODEL #011020-069-2 NATIONAL SITE ADAPT CONSULTANT: <br /> 143 G.C. 2" COUPLING (PRIMARY) "SMITH FIBERCAST" MODEL #012020-101-8 G H A U <br /> a � S <br /> o © 144 <br /> G.C. 2" 90 DEGREE ELBOW (PRIMARY) "SMITH FIBERCAST" MODEL #012020--360-4 <br /> 0 0 REINSTALL EXISTING 145 G.C. 2" 45 DEGREE ELBOW (PRIMARY) "SMITH FIBERCAST" MODEL #012020-310-4 I U <br /> 53 DISPENSER AND °y ��► .: ? <br /> EXISTING "BALANCE" 146 G.C, 2 TEE (PRIMARY) SMITH FIBERCAST MODEL #120020--410-4 4y, <br /> HOSES AND NOZZLES .r �Tj � �� <br /> 147 2" THREADED ADAPTER BELL x MALE FRP SMITH FIBERCAST" MODEL #012020-191-4 NG �NG0N <br /> G.C. "SMITH FIBERCAST" MODEL 012020-191-7 <br /> 148 <br /> G.C. 3" (SECONDARY) FIBERGLASS PIPE, 22'--25' LENGTH & GLUE KITS "SMITH FIBERCAST" MODEL #011030-069-5 "LAND PLANNING AND DESIGN SPECIALISTS" <br /> 18215 72ND AVENUE SOUTH <br /> OKENT, WASHINGTON 98032 <br /> 149 G.C. 3" COUPLING (SECONDARY) "SMITH FIBERCAST" MODEL #012030-101-9 (425) 251-6222 <br /> B-B NOT USED <br /> SCALE: 1" = 1'-0" 153 <br /> NO. DATE REVISION DESCRIPTION <br /> 154 G.C. 3" 90 DEGREE ELBOW (SECONDARY) "SMITH FIBERCAST" MODEL #012030-360-3 I 5-20-08 ISSUED FOR PLAN CHECK <br /> 187 FIELD RETROFIT EXISTING POWER/DATA PRODUCT SHEAR VALVE 81 82 VAPOR SHEAR VALVE 155 G.C. 3" 45 DEGREE ELBOW (SECONDARY CROSSOVER) "SMITH FIBERCAST" MODEL #012030-311-3 z <br /> CONDUIT TO NEW DISPENSER SUMP. <br /> 3 <br /> DISPENSER PULL BACK EXISTING WIRING (TYP.) G.C. TO FIELD FORM 156 G.C. 3" TEE (SECONDARY CROSSOVER) "SMITH FIBERCAST" MODEL #120030-411-3 a <br /> SUMP SENSOR 189 J-BOX 81 PRODUCT SHEAR VALVE (TYP.) NEW CONC. ISLAND 5 <br /> J-BOX DRIVE SLAB (TYP.) (TYP.) 164 G.C. 2"x1�-1/2" FEMALE NPT REDUCER BUSHING (PRIMARY) "SMITH FIBERCAST" MODEL #012020-231-4 <br /> 6 <br /> DISPENSER SKIN '4 A ADDITIONAL SIMILAR FRP FITTING TYPES MAY BE REQUIRED AND SHALL 7 <br /> �� 82 VAPOR SHEAR VALVE > G.C. BE PROVIDED BY THE CONTRACTOR. "SMITH FIBERCAST" <br /> a <br /> CONTRACTOR TO ° ° 170 G.C. 3"x2" RUBBER REDUCER W/ TEST PORT "DPW" MODEL # TBA-3020 <br /> :a .... _�.. _..._...... .a........... <br /> FIELD FORM s <br /> SEAL OFF (TYP.) 192 NEW 6" a 4 p "TITEFLEX" MODEL # 111430-24-0180 (U. 0 <br /> DISPENSER a a. . 4 a a A 172 G.C. 1-1/2"x18" LONG FLEX CONNECTOR — 1-1/2" MALE SWIVEL x 2" FEMALE LISTED) <br /> a ISLAND a a �i <br /> " °' o ® 187 G,C, 3/4" OR 1" RIGID CONDUIT BY G.C. 2 <br /> FIELD RETROFIT 2" INSIDE 3" <br /> EXISTING MONITORING 187 _ o ® 142 148 FRP PIPING a SEAL: <br /> 3, FESS1 <br /> CONDUIT TO NEW 1--1/2"x 18" LONG MALE SWIVEL x 2" 172 ® ® ® ® +�' z 189 G.C. J-BOX EXP. PROOF "CROUSE HINDS" 1" GUA SERIES �O QRd �Nq% Fy <br /> SUMP, PULL BACK FEMALE FLEX CONNECTOR ® ® CROUSE HINDS 1 EYS3 VERTICAL OR a, <br /> ® ® ® ® 192 G.C. SEAL OFF = <br /> EXISTING WIRING o ® � a <br /> o EYS31 VERTICAL 4R HORIZONTAL c� y <br /> 0 o UNDER DISPENSER ( ) �, HAL P. GRUBS <br /> (TYP.) <br /> 172 1-1/2"x18" FLEX CONNECTOR CONTAINMENT SUMP 88 ° I <br /> n Ef, w <br /> ® o ® ® ® o G.C. SUMP LIQUID SENSOR (EXISTING TO BE RE-USED) "VEEDER--ROOT" MODEL NO. 794380-208 fi7814 o <br /> REINSTALL 0 ® ® �� �� �\/��\/��\/��\ <br /> ® ® ® ® 142 2" FRP VAPOR LINE SUMP SENSOR 201 �� � � m <br /> 201 ® ® 2a1 "OPW/POMECD" MODEL NO. 6/30/ m <br /> EXISTING SUMP IN HOLDER a G.C. 5 GALLON FILL/VAPOR REPLACEMENT BUCKETS �'�, <br /> SENSOR IN rr <br /> 2 1- - � <br /> 131 ENTRY BOOT <br /> HOLDER3" ENTRY 132 OP CALVE ,� <br /> UNDER DISPENSER CONTAINMENT BOOT <br /> CONFIDENTIALITY STATEMENT- <br /> \_<2" H- <br /> THE RECIPIENT OF THESE MATERIALS UNDERSTANDS THAT <br /> 2" INSIDE 3" FRP 142 148 <br /> PRODUCT LINE COPYRIGHT IN THE MATERIALS IS OWNED UY BP, AND ALSO, <br /> THAT THE MATERIALS CONTAIN PRIVILEGED AND CONFIDENTIAL <br /> DUSINE55 INFORMATION OF BP. ACCORDINGLY, THE <br /> RECIPIENT AGREES TO RETAIN THESE MATERIALS IN STRICT N <br /> NOTE: CONFIDENCE AND AGREES NOT TO DISCLOSE THESE <br /> MATERIALS TO ANY OTHER PARTY AND 3" ENTRY BOOT 132 IF REQUIRED BY LOCAL CODES, NOT <br /> TO MAKE <br /> MATERIALS ONLY OR FURTHER <br /> RECIPIENT <br /> MITED NT <br /> PURPOSE FOR WHICH UP MADE THE <br /> EXTEND CONCRETE UNDER AVAILABLE, ANDRECIPIENT HAS <br /> AGREES TO RETURNRIALS ALL <br /> MATERIALS TO SP EITHER UPON COMPLETION OF THE <br /> BOLLARD BELOW THE FROST INTENDED PURPOSE OR UPON THE REQUEST OF BP, <br /> LINE <br /> SECTION C-C: ELEVATION DETAIL @ SUMP BOX • PIPE VER COMES <br /> PIPE AND TANKKDESIGN DISCLAIMER: o <br /> U <br /> r, r ,r BP DOES NOT AND CANNOT WARRANT THAT THE PLANS FOR <br /> SCALE: 1 =1 -0 PETROLEUM STORAGE AND DISPENSING ARE COMPLIANT WITH <br /> ALL LEGAL REQUIREMENTS THAT EXIST OR AS THEY MAY BE <br /> APPLIEEXISTING GILBARCO B H 1 DISPENSER ELEVATIONS CONFORMITY <br /> IN TME FUTURE. NAR DOES ILL BP WARRANT THAT A <br /> FUELING STORAGE AND DELIVERY SYSTEM CONSTRUCTED IN Q <br /> CONFORMITY WITH THESE PLANS WILL BE FREE OF ALL <br /> LEAKS. YOU ARE ACCORDINGLY STRONGLY ENCOURAGED TO <br /> CONSULT WITH A FUELING STATION ENGINEER OF YOUR <br /> CHOOSING TO INDEPENDENTLY EVALUATE WHETHER THESE p0 <br /> PLANS ARE TRULY SUFFICIENT FOR CONSTRUCTING THE <br /> STORAGE AND DELIVERY SYSTEM AT YOUR STATION. co <br /> DEVELOPMENT INFORMATION: o <br /> "A" SIDE OF DISPENSER N <br /> REINSTALL EXISTING UNDERGROUND STORAGE <br /> DISPENSERS AND TANK STANDARDS <br /> EXISTING HANGING <br /> i- <br /> HARDWARE <br /> I� SB-989 SUMP REPLACEMENT�EXISTING DISPENSER TO <br /> SUMP SENSOR J-BOX I i BE RE-USED (TYP.) o <br /> CONTRACTOR TO FIELD FORMI <br /> NEW 6" DISPENSER ISLAND SITE ADDRESS: <br /> C 82 VAPOR SHEAR VALVE I I I I <br /> I I � <br /> 2" FRP ELBOW WITH 2" FRP X I I I I <br /> 164 144 81 PRODUCT SHEAR VALVE I I DISPENSER JUNCTION 1711 E YOSEMITE <br /> 1-1/2" FNPT BUSHING O SEAL-OFF (TYP.) 1.� BOX (TYP.) CD <br /> MANTECA, CA <br /> ASPHALTIC I I I Qa <br /> CONCRETE SLAB 4 as EXPANSION JOINT DISPENSER I o <br /> 0 <br /> SUMP FRAME.... I� o <br /> a a I NEW CONC. FACILITY No. 06020 <br /> q a 4 DISPENSER <br /> a SENSOR MOUNTING ISLAND (TYP.) DESIGNED BY: ALLIANCE Z&DM: o <br /> 2" DOUBLE ENTRY BOOT 172 1-1/2" x 18" HANGER KIT (TYP.) JP10V <br /> 131 FLEX CONNECTOR <br /> CHECKED BY: BP REPM: <br /> 2 SINGLE WALL FRP 142 e DRAWN BY: dP ALLIANCE PM: Q) <br /> " RECOVERY LINE 187 SUMP SENSOR IN <br /> V <br /> HOLDER MONITORING187 o VERSION: PROJECT NO: —c <br /> 3" OVER 2" DOUBLE 148 142 CONDUIT RUN CONDUITS THROUGH BCE #3518 <br /> WALL FRP PRODUCT 133 CONDUIT PENETRATION CUT OUTS IN DISPENSER E <br /> LINE FITTING SUMP FRAME OR INSTALL DRAWING TITLE: U) <br /> REINSTALL EXISTING PENETRATION FITTINGS IN DISPENSER SUMP DETAILS: Lo <br /> 3" ENTRY 132 — 201 SUMP SENSOR 1N SUMP (BY G.C.) (TYP.) <br /> GILBARCO 13111 <br /> BOOT C HOLDER NARROW FRAME <br /> i <br /> DISPENSER <br /> V <br /> 3"X2" TEST REDUCER 170 _ —�-COMPACTED OR NATIVE POWER <br /> 187 & <br /> PEA GRAVEL I— —I i SOIL DATA CATCONDUIT <br /> (TYPICAL)) EXISTING SUMP SHEET NO: <br /> UNDER DISPENSER CONTAINMENT MONITOR LIQUID 201 E <br /> 88 SUMP SENSOR TO BE �O <br /> RE-USED <br /> cci <br /> TK2= 1 o <br /> CD <br /> CD <br /> SECTION D-D: SECTION THROUGH DISPENSER ISLAND DISPENSER CONTAINMENT SUMP CONDUIT ROUTING DETAIL <br /> SCALE: 1"=l'-O" SCALE: NONE <br />
The URL can be used to link to this page
Your browser does not support the video tag.