SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2900 - Site Mitigation Program
>
PR0543479
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:58:34 AM
Creation date
5/5/2020 9:11:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0543479
PE
2960
FACILITY_ID
FA0024679
FACILITY_NAME
CANEPA'S CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95204
APN
081360030
CURRENT_STATUS
01
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
613
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Scope of Work <br /> 7 <br /> Canepa's Car Wash — 6230 Pacific Street <br /> June 21 , 2001 <br /> Page -2- <br /> TASK 3 — Site Preparation <br /> • This task includes a site visit to mark boring locations for underground and overhead <br /> utility clearance and to review any utility drawings provided by the client. <br /> TASK 4 — Cone Penetrometer Testing and Groundwater Sampling <br /> • Condor will conduct CPT to assess the site lithology, soil contamination, and groundwater <br /> contamination . In three locations, the CPT will penetrate to approximately 35 feet below <br /> grade and take soil samples just above and just below the existing water elevation . In three <br /> different locations, the CPT will penetrate to approximately 120 feet below grade to assess <br /> the site lithology. Based on the lithology, the CPT will be used to take discrete <br /> groundwater samples at an estimated three depths between 70 and 120 feet below grade. <br /> TASK 5 — Monitoring Well Installation, Development, and Surveying <br /> • Condor will install 6 new monitoring wells. Three monitoring wells will be installed to a <br /> depth of approximately 100 feet. Three additional wells will be installed to a depth of 45 <br /> feet. The shallow wells will have slotted casings that extend above the existing <br /> groundwater elevation . Limited soil sampling will occur as part of the well installation. <br /> Groundwater monitoring will be conducted as part of quarterly monitoring. <br /> TASK 6 — Report Preparation <br /> • Condor wil I prepare a report on the additional investigation activities and results . <br /> TASK 7 — Quarterly Monitoring of New Monitoring Wells for One Year <br /> • Condor will conduct continued quarterly groundwater monitoring at the site. The quarterly <br /> groundwater monitoring program consists of collecting groundwater elevation <br /> measurements from the eight existing monitor wells and a groundwater sample from the <br /> existing monitor wells and one of the nine site SVE wells. One year (four quarters) of <br /> groundwater monitoring of the new wells are included in this scope of work. For each <br /> monitoring event, groundwater samples collected from the monitor wells and SVE well <br /> will be analyzed for benzene, toluene, ethyl benzene, and total xylenes (BTEX), and MTBE <br /> by EPA Method 8020 and total petroleum hydrocarbons quantified as gasoline (TPH-G) by <br /> EPA Method 50301LUFT. For each monitoring event, Condor will prepare a quarterly <br /> groundwater monitoring report for submittal to the CRWQCB and the SJC PHS/EHD. <br /> Each report will include site background information, a description of the field work and <br /> monitoring results, a discussion of well monitoring data to date, site maps showing <br /> groundwater elevation and chemical iso-concentration contours, and laboratory reports that <br /> include analytical methods, sample detection limits, and results of the analyses. <br /> \\Pdc\projects\1707 Canepa-Pacific\Contracts\2001 Addendum\WorkScope6.21 .01 .doc <br />