My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2023 10:33:18 AM
Creation date
5/5/2020 3:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Apr 27 1.2 12:24p Reliable PetroleumA 209-845-8953 p.3 <br /> I <br /> I <br /> Monitoring System Ceitirecation <br /> D. Results of Testi I'glSerwicing <br /> Software Version Installe 329.00 <br /> CoTEOINO'"iFor <br /> callowin heck1ht: <br /> NO Is e audible alarin operational? <br /> NO is a visual alarm operational? <br /> ® O* W re all sensors visually inspected, functionally tested,and confirmed operational? <br /> 13 o* W e all sensors installed at lowest point of secondary containment ar.d positioned so that they equipment dill <br /> not Interfere with their proper operation? <br /> No* If latrns are relayed to a remote monitoring station, is all communications equip eat (e.e., modem) <br /> /A op tional?o* Fo 'pressurized piping systems, does the turbine automatically shut down if the piping se ondary containment <br /> IA mo storingsystem detects a leak,fails to operate; or is electrically disconnected? If yes: hick sensors initiate <br /> pos ive shut-down? (Check Jll,Hurt apply) Sump;Trench Sensors; $ Dispenser Conta went SensorsDid you confirm positive shut-down due to leaks andsensor fail urerdisconnection?a# For tan: systems that utilize tfie monitoring system as the rim ®Yes [ No. <br /> p any tank overfi'l wa ing device (i.e., no <br /> 171 N/A . .m apical vvefilt prevention valve is installed), is the overfill wattling alarm visible as I audible at the tank <br /> fill int(s)and operating properly? If so,at what percent of lank capacity does the alarm t iggcr" 9096 <br /> ❑ Yes* ® No Was lacy monitoring equipment replaced? If yes, identify specific sensors,probes,or other-equipment <br /> and ist the manufacturer name and model.for all replacement parts in Section E, below• replaced <br /> Yes" ❑ No Was liquid round inside any secondary containment systems designed as dr systems? Ch cic all that apply) <br /> ❑P oduct; ❑ Water. lfyes, describe causes in Section 8, belown } y r FPY) <br /> ® Yes Q No* Was monitorin system gset-up reviewed to ensure proper settings?,Attach set up repo ts, if plical>le <br /> ® Yes ❑ Nc* Is al monitoring equipmert operatiorai per manufacturer's specifications? <br /> * fn Section E below,cleso.Iribe how and when these deficiencies were or will be corrected. <br /> E. Comments: Founcl very small amount of rain water in the 67&89 fill SUMPS and 87 STP sumo. R moved wafer and <br /> placed water in <br /> I <br /> i <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.