Laserfiche WebLink
f----2'-10 7/8° -� THIS DETAIL IS FOR REFERENCE <br /> ONLY. SIGNAGE SUPPLIED AND <br /> 71 INSTALLED BY OTHERS UNDER O <br /> SEPARATE PERMIT. <br /> 4'-6" (1370mm) CL 7 - 8" (2335mm) 20° <br /> J✓ <br /> 4'4 3/8" 36"x 36" MIN. CLEAR AREA 13' -3" (4040mm) �O <br /> SIGN C 6 x FOR CONTROL BOX <br /> 5'-7 3/8" STEELL CHANNEL MIN. CLR. AREA <br /> CABINET (2)TOTAL (2) CONDUIT FROM CONTROL r---------- / (1) CONDUIT, ROUTE TO X; O <br /> BOX, ROUTE TO DRIVE THRUI ELECTRICAL PANEL `� ©2011 STARBUCKS COFFEE <br /> WINDOW I I \ / <br /> B1) CONDUIT FROM 0X, ROUTE TO ELECOTRICAOL ---- ----- ---------------\\ STARBUCKS COFFEE <br /> --- -- ----------- CONCRETE FOOTING ��O <br /> 1'-2718" o TYP. PANEL I <br /> I OUTLINE OF MENU COMPANY <br /> NON-ILLUMINATED t ----��\ I \ BOARDw <br /> BOLLARD <I <br /> 2401 UTAH AVENUE SOUTH <br /> I I / Q` <br /> (3)#3 TIES TOP 5"_ � a �_ __� _ / � _ _ _ I_ !, SEATTLE, WASHINGTON 98134 <br /> N < I Q`V (206) 318-1575 <br /> #3 TIES @ 6"O.C. CONSOLIDATED _ _ Q. <br /> 2'-11" REMAINDER CONC,fc=2500 psi U I / �^� ` THESE DRAWINGS AND SPECIFICATIONS ARE <br /> (10)#5 VERTS. c� Z I E �J CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> EQUALLY SPACED PROPERTY OF STARBUCKS CORPORATION,WHICH IS <br /> 3"CLEARANCE o E ^ 00 THE OWNER OF THE COPYRIGHT IN THIS WORK. <br /> V-4" T o ------- o r THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN <br /> I <br /> WIDTH �? o PART), SHARED WITH THIRD PARTIES OR USED IN AN- 2'-4"LENGTH�- I N o N MANNER ON OTHER PROJECTS OR EXTENSIONS TO <br /> THIS PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. THESE <br /> DRAWINGS AND SPECIFICATIONS ARE INTENDED TO <br /> \ CONCRETE FOOTING E EXPRESS DESIGN INTENT FOR A PROTOTYPICAL <br /> ELEVATION NOTES: E STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE <br /> 1.7 N.T.S. 1. IF UTILIZING EXISTING FOOTING(S) FOR \ OUTLINE OF DIGITAL ORDER SCREEN p U AT ANYTIME)AND DO NOT REFLECT ACTUAL SITE <br /> 0 SIGNAGE INSTALLATION, FASTEN TO \ WITH CONTROL BOX z <br /> � � \ N g CONDITIONS. NEITHER PARTY SHALL HAVE ANY <br /> U EXISTING THREADED BOLTS AND <br /> -I 2-4" PROVIDE CONDUIT AS NOTED. ENSURE \ \ EDGE OF CONCRETE CURB T OBLIGATION NOR LIABILITY TO THE OTHER(EXCEPT <br /> STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> BOLTS ARE IN SOUND CONDITION. CONDUIT TO CONTROL BOX Q FULLY EXECUTED BY BOTH PARTIES. <br /> 2'-1 3/4" 2. IF ABANDONING EXISTING FOOTING(S) IN <br /> o r PLACE, CUT CONDUIT AND THREADED DETECTOR LOOP EDGE CENTERED ON SPEAKER POST J <br /> C 6 x 10.5 BOLTS FLUSH TO TOP OF FOOTING. 2" (50mm) BELOW FINAL GRADE IN CONDUIT OR SAWCUT. <br /> ARCHITECT OF RECORD <br /> 06 STEEL CHANNEL VERIFY NO METAL IN SLAB WITHIN 36" (915mm) OF LOOP. THIS DETAIL IS FOR REFERENCE O o a <br /> (2)TOTAL <br /> ONLY. SIGNAGE SUPPLIED AND0 7 <br /> N R <br /> C 1-4 1-2 4® ® TYP. INSTALLED BY OTHERS UNDER A o • <br /> U 4J U <br /> �I —� E7oxx SEPARATE PERMIT. ���/ " " <br /> 3116Cz <br /> C7 ` C/)0 O <br /> r <br /> 1/2"DIA.,24"MIN.EMBED. mcg a r c h i t e c u r <br /> m CONSOLIDATED J ST'L HEADED BOLTS !'� 111 Pacifica,Suite 280, Irving,CA 92618 <br /> CONIC,fc=2500 psi NP' <br /> P:949.553.1117 F:949.474.7056 <br /> CSI �� <br /> N \&\ BASE PLATE P _ <br /> Q� ARCHITECT STAMP <br /> aSE� ASC <br /> 0') N.T.S. P C' <br /> n t=1-3/4" <br /> i7 INCO a <br /> > 9 <br /> ( � DIGITAL ORDER SCREEN FOOTING DTE - 5 PANEL 209 DT MENU BOARD, DIGITAL ORDER SCREENI <br /> P--..,2019 � <br /> r I L <br /> \�\ Scale: 1/2" = 1'-0" \� EXE scale: 1/2" = V-0" <br /> c� <br /> U <br /> Q <br /> CV THIS DETAIL IS FOR REFERENCE THIS DETAIL IS FOR REFERENCE THIS DETAIL IS FOR REFERENCE <br /> C:) ONLY. SIGNAGE SUPPLIED AND ONLY. SIGNAGE SUPPLIED AND Q <br /> ONLY. SIGNAGE SUPPLIED AND <br /> p INSTALLED BY OTHERS UNDER INSTALLED BY OTHERS UNDER INSTALLED BY OTHERS UNDER <br /> c� SEPARATE PERMIT. SEPARATE PERMIT. SEPARATE PERMIT. <br /> �V✓ 1 I <br /> UI �O .�. <br /> Cz <br /> �P w . � <br /> (D O <br /> I I <br /> E Q <br /> oDIGITAL ORDER �" U) z (� <br /> } SCREEN (DOS) W 0 <br /> Q'` W m Z <br /> � DOS POST; Q 0p U <br /> o DOS POST CLAMP �Rw Z Z Q D <br /> FRAME UNISTRUT TO W <br /> POST AND U U � <br /> M BOLT DCB TO � I O 7 O m ZQ <br /> ao <br /> UNISTRUT L <br /> T__ DOS CONTROL 0Y CV CC <br /> X BOX FASTENED <br /> pp TO FRAME DIGITAL ORDER <br /> C/)I SIGN WITH BASE SCREEN BEYOND STORE #: 11830 <br /> N AND PLATE COVER <br /> M <br /> CV (BY STARBUCKS) I I PROJECT #: 37913-049 <br /> rn \ CASEWORK CONCEPT: CORE <br /> r <br /> U) THIS DETAIL IS FOR REFERENCE ISSUE DATE: <br /> Y ONLY. SIGNAGE SUPPLIED AND PROGRAM MANAGER: M.DREBIKA <br /> INSTALLED BY OTHERS UNDER STORE DESIGNER: T.MARINIC <br /> PARATE PERMIT. LEEDGAP: N/A <br /> Q Q 30° CHECKED BY: <br /> C) E <br /> CONDUIT WITH L-- <br /> ^ __--_ � -------- -\--- MCG PROJECT#: 19232 <br /> E ROUTE DOS X E z WATERTIGHT <br /> Q E p MCG PROJ. MANAGER: C.LEE <br /> CD POWER WHIP TO 2 E o U COUPLING PER 1 CONDUIT ROUTE MCG PROJ. SPECIALIST: SPARK <br /> �, DOS CONTROL BOX 0 � X ELECTRICAL ( ) <br /> 'p T GRADE REMOVABLE POST FINISHT z E o � CONDUIT PER � w /°LU ° \I TO SIGNAGE POWER <br /> COVER o N r ELECTRICAL o Q Revision Schedule <br /> �� °/ <br /> POST BASE ` v POST BASE 2 0 Rev Date By Description <br /> oSHROUD 0 E \ OUTLINE OF MENU <br /> N SHROUD z c, <br /> BOARD <br /> CONCRETE III , III III III III ' I o CONCRETE FOOTING <br /> FOOTING l'L I_ -i �- <br /> CONCRETE � �° � � � -_� GRADE z E I � � I <br /> GRADE SEE ADDITIONAL <br /> I I FOOTING CONSTRUCTION <br /> CONDUIT PER = � -_—_� �// / \�\ _ POST FOOTING `Y' DETAILS FOR <br /> Q I I ELECTRICAL �� i BEYOND <br /> M I I SECTION / \ <br /> I I � SHEET TITLE: <br /> EDGE OF CONCRETE CURB DRIVE THRU & SITE <br /> 0 <br /> I I 20'-0" (6M)TO CENTERLINE OF DETAILS <br /> r I I <br /> rn ORDER POINT <br /> SCALE:AS SHOWN <br /> T <br /> 51 DIGITAL ORDER SCREEN - ELEVATION _ 3 �Sca � <br /> CONTROL BOX AT DOS POST - SECTION 2 , DOS CONTROL BOX ON DOS POST 1 DTE - PRE-MENU 30 DEG SHEET NUMBER: <br /> \__— Scale: 1" = V-0" 1' 0" \ \ Scale: 1" = V-0" Scale: 1/2" = V-0" <br /> A503 <br /> T <br /> T <br />