My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 2:27:53 PM
Creation date
5/7/2020 9:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO 06080 85 E LOUISE AVE, LATHROP February 01, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> The facility failed to maintain alarm logs and records of follow up actions. The following alarms were not entered <br /> into the log book and addressed by the facility: <br /> S11:91 Product Communication Alarm on 2/14/16 and 2/27/16; <br /> S7:87 Product Vacuum Communication Alarm on 2/23/16; <br /> S11:91 Product Vacuum Warning and Communication and Sensor Fault Alarms on 7/26/16; <br /> Q2: Premium Gross Line Fail and PLLD Shutdown Alarm on 8/21/16; <br /> S11:91 Product Communication Alarm on 9/15/16; <br /> Unleaded Regular Sudden Loss Alarm on 10/28/16; <br /> Q2: Premium Gross Line Fail and PLLD Shutdown Alarm on 10/21/16; <br /> S10: Vapor Lines Communication Alarm on 11/19/16; and <br /> S12:91 Vent Communication Alarm on 12/19/16. <br /> All alarm records shall be maintained on site for at least three years. Monitoring records include: (1) date and time <br /> of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any <br /> visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges <br /> or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately implement a program for recording alarms in the daily alarm log and note what action <br /> was taken for each alarm. Maintain all maintenance, monitoring records and alarm logs on site going forth. <br /> This is a minor violation. <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004). <br /> The L8 87-product fill sump sensor 208 failed when tested. The continuous monitoring system shall be maintained <br /> to detect the entry of the liquid or vapor phase of the hazardous substance stored in the primary containment into <br /> the secondary containment and to detect water intrusion into the secondary containment. The sensor was replaced, <br /> like for like, and retested during the inspection. A"UST Retrofit Verification with Inspector Already Onsite" form has <br /> been completed and provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Communication in the 87-, 91-, and diesel- product submersible turbine pump (STP) sumps and fill sumps, and <br /> communication in the under dispenser containment(UDC) sumps were not tested during the annual monitoring <br /> system certification testing on February 1, 2017. The interstitial space of the underground storage tank system shall <br /> be maintained as designed under constant vacuum such that a breach in the primary or secondary containment is <br /> detected before the hazardous substance is released into the environment. Immediately contact a properly <br /> licensed, trained, and certified contractor to test communication of the vapor/pressure/hydrostatic (VPH) <br /> components listed above under permit and inspection by the Environmental Health Department(EHD). <br /> This is a minor violation. <br /> FA0003635 PR0231656 SCO01 02/01/2( <br /> EHD 23-01 Rev.09/22/16 Page 4 of 6 Underground Storage Tank Program <br />
The URL can be used to link to this page
Your browser does not support the video tag.