Laserfiche WebLink
110 Lancaster Laboratories 4 <br /> 2425 New Holland Pike Lancaster PA 17601 Explanation of Symbols and Abbreviations <br /> The following defines common symbols and abbreviations used in reporting technical data <br /> N D none detected BMQL Below Minimum Quantitation Level r <br /> TNTC Too Numerous To Count MPN Most Probable Number .' <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhoslcm NTU nepheiometnc turbidity units <br /> C degrees Celsius F degrees Fahrenheit <br /> meq milliequivalents lb pound(s) <br /> _ g gram(s) kg kilogram(s) <br /> Ug microgram(s) mg milligram(s) <br /> ml milliliter(s) I liter(s) <br /> m3 cubic meter(s) ul microliter(s) <br /> < less than -The number following the sign is the limit of quantitation, the smallest amount of analyte which can be <br /> reliably determined using this specific test b <br /> > greater than <br /> J estimated value-The result falls within the Method Detection Limit (MDL) and Limit of Quantitation (LOQ) <br /> PPM parts per million - One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram For gases or vapors, one ppm Is equivalent to one microliter of gas per liter of gas <br /> ppb parts per billion <br /> Dry weight Results printed under this heading have been adjusted for moisture content This Increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture All other results are reported <br /> on an as-received basis <br /> U S EPA CLP Data Qualifiers <br /> Organic Qualifiers Inorganic Qualifiers _ • <br /> A TIC is a possible aldol-condensation product B Value Is <CRDL, but?IDL <br /> B Analyte was also detected in the blank E Estimated due to Interference <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met �. <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits . <br /> _ E _Concentration exceeds the calibration range of 5 Method of standard additions (MSA) used <br /> the instrument for calculation --T--- - <br /> N Presumptive evidence of a compound (TLCs only) U Compound was not detected <br /> P T Concentration difference between primary and T W—Post digestion spike-outof control limits <br /> _ _confirmation columns >25% _ Duplicate analysis not within control limits <br /> U Compound was not detected-� + Correlation coefficient for MSA<0 995 <br /> X,Y,Z Defined in case narrative <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis <br />- Measurement uncertainty values, as applicable, are available upon request <br /> Tests results relate only to the sample tested Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless If you have questions regarding the proper techniques of collecting samples, please contact <br /> us We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our ` <br /> staff This report shall not be reproduced except in full, without the written approval of the laboratory <br /> WARRANTY AND LIMITS OF LIABILITY- In accepting analytical work,we warrant the accuracy of test results for the sample as submitted <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF (A)THE NEGLIGENCE (EITHER SOLE OR CONCURRENT)OF LANCASTER <br /> LABORATORIES AND (B) WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br /> DAMAGES We accept no legal responsibility for the purposes for which the client uses the test results No purchase order or other <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client <br /> 376801 <br />