My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013145
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WIGWAM
>
2365
>
2600 - Land Use Program
>
PA-2000054
>
SU0013145
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2020 1:57:51 PM
Creation date
5/8/2020 11:46:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013145
PE
2631
FACILITY_NAME
PA-2000054
STREET_NUMBER
2365
Direction
N
STREET_NAME
WIGWAM
STREET_TYPE
DR
City
STOCKTON
Zip
95205-
APN
13208012
ENTERED_DATE
4/3/2020 12:00:00 AM
SITE_LOCATION
2365 N WIGWAM DR
RECEIVED_DATE
4/3/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
show compliance with the current California codes and San Joaquin County ordinances . A <br /> complete set of plans must include fire sprinkler plans , truss design submittals , metal building <br /> shop drawings , structural plans and calculations , plumbing , electrical and mechanical drawings <br /> and energy report . <br /> ( 4 ) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> ( 5 ) For each proposed new building , provide the following information on the plans : <br /> A . Description of proposed use <br /> Be Existing and proposed occupancy Groups <br /> Co Type of construction <br /> D . Sprinklers ( Yes or No ) <br /> E . Number of stories <br /> F . Building height <br /> G . Allowable floor area <br /> H . Proposed floor area <br /> I . Occupant load based on the CBC <br /> J . Occupant load based on the CPC <br /> ( 6 ) If high piled combustible storage is to be used in a building , an automatic fire sprinkler system <br /> will be required . <br /> ( 7 ) Accessible routes shall be provided per CBC § 11 B -206 . At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones ; public streets and sidewalks ; and public transportation stops to the accessible building <br /> or facility entrance they serve . Where more than one route is provided , all routes must be <br /> accessible . § 11 B - 206 . 2 . 4 <br /> ( 8 ) At least one accessible route shall connect accessible buildings , accessible facilities , <br /> accessible elements and accessible spaces that are on the same site . § 11 B -206 . 2 . 2 <br /> ( 9 ) At least one accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility , including mezzanines , which are <br /> otherwise connected by a circulation path . § 11 B -206 . 2 . 4 <br /> ( 10 ) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code . Note that accessible parking spaces are required <br /> for each phase of the project . These parking space ( s ) shall be located as close as possible to <br /> the primary entrance to the building . <br /> ( 11 ) Adequate sanitary facilities shall be provided for the facility , per the requirements of Chapter 4 <br /> of the California Plumbing Code . <br /> ( 12 ) Pursuant to Section 422 . 4 of the California Plumbing Code , toilet facilities shall be accessible <br /> to employees at all times , should not be more than 500 feet from where employees are regularly <br /> employed and accessible by not more than one flight of stairs . The plans shall indicated the <br /> location of the toilet facilities and the travel distance from work areas . <br /> ( 13 ) This project will be required to comply with the Model Water Efficiency Landscape Ordinance <br /> requirements of the California Code of regulations , Title 22 , Division 2 , Chapter 2 . 7 <br /> PA-2000054 — Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.