My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2012 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 4:03:34 PM
Creation date
5/8/2020 11:48:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2015
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Facility Name: Arco #6080 (Page 4) <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> Manufacturer: Veeder-Root Model : 332117-001 System Type: ❑ Pressure ❑Vacuum <br /> Sensor <br /> ID <br /> s7 Component(s) Monitored by this Sensor: 87 Product Line <br /> Sensor Functionality Test Results: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ® Pass: ❑ Fail <br /> s9 Component(s) Monitored by this Sensor: 87 Vent Line <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass: ❑ Fail <br /> s10 Component(s) Monitored by this Sensor: Vapor Line <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass: ❑ Fail <br /> S11 Component(s) Monitored by this Sensor: 91 Product Line <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass: ❑ Fail <br /> s12 Component(s) Monitored by this Sensor: 91 Vent Line <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass: ❑ Fail <br /> s13 Component(s) Monitored by this Sensor: Diesel Product <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass: ❑ Fail <br /> s14 Component(s) Monitored by this Sensor: Diesel Vent <br /> Sensor Functionality Test Results: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass: ❑ Fail <br /> How was interstitial communication verified? <br /> ❑ Leak Introduced at Far End of Interstitial Space; ❑ Gauge; ❑ Visual Inspection; Other (Describe in J below) <br /> Vacuum was restored to operating levels in all interstitial spaces: ® Yes ❑ No (If no, describe in J below) <br /> J. Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.