COMPLIANCE INFO_2012 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2012 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 4:03:34 PM
Creation date
5/8/2020 11:48:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2015
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
kip <br /> 0 <br /> LINE LEAK DETECTOR TEST <br /> Facility#: 6080 Date: 02/28/13 <br /> Address: 85 Louise Ave. <br /> City, State:Lathrop, CA 95330 <br /> Testing Information <br /> Product: 87 91 DSL <br /> Manufacturer Veeder-Root Veeder-Root Veeder-Root <br /> Leak Detector Serial Number 313360 290325 313363 <br /> Leak Detector Model No. 848480 848480 848480 <br /> Full Operating Pressure (psi): 30 30 30 <br /> Test Leak Rate (ml/min)(gph) 3.00 3.00 3.00 <br /> Bleed Back Rate (ml): N/A N/A N/A <br /> Turbine Holding Pressure (psi): 0 0 0 <br /> Metering Pressure (psi): N/A N/A N/A <br /> Open/Trip Time (mechanical only): N/A N/A N/A <br /> Pass/Fail Pass Pass I Pass <br /> Comments: <br /> Note: Pass= Leak detector reads leak and meters line. <br /> Fail= Leak detector did not read leak. <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br /> manufacturers procedures and limitations and the results as listed are to my knowledge true and correct.The mechanical leak test <br /> detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> ispected By: Contractor FASTECH-Fueling&Services Technologies, Inc. <br /> Technician: Isaac Anderson Alltech Petro Inc. Lic#: 623541 A-Haz <br /> Signature: <br />