by <br /> <"011 Emergency Shut-Off (ESO) Testing Results & Checklist <br /> Facility Information Contractor Information Test Results <br /> Site# 6080 Co.Name: FASTECH Date:02/28/13 <br /> Addr. 85 Louise Ave. Phone: 714-523-0194 <br /> City/St:Lathrop,CA Lead Tech: Isaac Anderson(Alltech Petro) PASS <br /> eMaint.W.O.# 9875683 1 Name: Isaac Anderson(Alltech Petro) or <br /> Pass ort# IB3687 lfl FAIL(Next Day Repair Required) <br /> Si nature: <br /> The objective of this test is to provide assurance that when the ESO switch is activated,X1 L fueling system circuits(turbines,and dispensers)are de- <br /> energized,and remain de-energized until they are re-set manually. The test procedures and guidelines shall be in accordance with the ESO Testing Process. <br /> X To Select <br /> # The following information is to be completed. <br /> Yes No N/A <br /> SITE DATA <br /> 1 Number of ESO s 1 <br /> 2 Type of Switch 4 Push Pull util Monentary ✓ Plain light(Toggle Other: <br /> if Momentary type,locate and identify re-set button): <br /> 3 Type of Turbine Control Relay System(Electrical Distribution Center): <br /> Brown Box h44 Power Solution Custom Fabricate( mil Carolina Box ✓ Other <br /> 4 IType of Turbine Control Relays: ✓ Make FE Petrn Model jst- M <br /> 5 Type of Line Leak Detection: Mechanical ELD/CPT V PLLD <br /> PERFORMANCE TEST <br /> 6 Does the ESO shutdown power to the DISPENSERS? ✓ <br /> 7 Does the ESO shutdown power to the TURBINES? ✓ <br /> Is the 220 voltage to the turbine relay removed(either the line side or the motor side of the contacts or the ✓ <br /> 8 coil)? <br /> 9 Are the DISPENSER BREAKERS clearly identified /labeled? ✓ <br /> 10 Are the TURBINE BREAKERS clearly identified / labeled? ✓ <br /> 11 Are all the ESOs accessible and clearly identified/ labeled? ✓ <br /> Did the ESO(s)function correctly(de-energized from either the line side or the motor side of the contacts ✓ <br /> 12 or the coil)? <br /> If#12 is NO,briefly describe what was wrong: <br /> 12A <br /> How was it corrected: <br /> 12B <br /> 12C If repair or ESO functionality cannot be corrected same day(prior to leaving the site). The technician MUST notify the <br /> Site Manager of the problem,place an"Out of Service"Tag on the ESO(s),and identify an alternate mean(i.e.,locate <br /> circuit ane),clear) identifyturbine and dispenser breakers for shut-off in the event of an emergency). <br /> Elite Customer Solution Center has been contacted for the repair. — <br /> 12D <br /> eMaint.W.O.Tick <br /> POST TEST <br /> 11 Site's fueling system is fully operational. ✓ <br /> 12 All equipment secured and any access ports,lids,enclosures are closed. _✓ <br /> 13 lAll safety barricades,and any debris was been removed. ✓ <br /> COMMENTS <br /> Submit completed copy with other documentation in E-Maintenance. <br />