My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2300 - Underground Storage Tank Program
>
PR0231656
>
COMPLIANCE INFO_2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2022 1:11:57 PM
Creation date
5/8/2020 3:44:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231656
PE
2351
FACILITY_ID
FA0003635
FACILITY_NAME
ARCO 06080
STREET_NUMBER
85
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 4. TANK ANNULAR TESTING 11 <br /> Test Method Developed By: 0 Tank Manufacturer 0 Industry Standard 0 Professional Engineer <br /> El Other(Specify) <br /> Test Method Used: El Pressure 0 Vacuum D Hydrostatic <br /> [I Other (Specify) <br /> Test Equipment Used: DIAL GAUGE Equipment Resolution:0 to 15"Hg Vacuum <br /> % <br /> qw, <br /> Tank Tank Tank Tank <br /> WIN <br /> Is Tank Exempt From Testing?' [I Yes El No 0 Yes ❑No El Yes 0 No EJ Yes El No <br /> Tank Capacity: GALLONS GALLONS GALLONS GALLONS <br /> Tank Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: <br /> Product Stored: <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RT): HG "HG 'HG "HG <br /> Test End Time: <br /> Final Reading(R,:): HG "HG "HG 'HG <br /> Test Duration: I Hour 1 Hour 1 Hour . 1 Hour <br /> Change in Reading(RF-114): HG "HG "HG HG <br /> Pass/Fail Threshold or Criteria: Zero Zero Zero Zero <br /> Test Result: 0 Pass 0 Fail ❑ Pass E]Fail 0 Pass 0 Fail D Pass: C)Fail. <br /> Was sensor removed for testing? [I Yes [I No 0 NA 0 Yes [I No [I NIA El Yes El No 0 NA El Yes El No 0 NA_ <br /> Was sensor properly replaced and El Yes El No DNA 0 Yes El No [INA 0 Yes El No 0 NA El Yes El No [INA <br /> verified functional after testing? <br /> Comments—(include information on re airs made pi tot to testing,and recommended failed tests) <br /> Secondary containment systems where the continuous monitor ing automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations, Title 23,Section 2637(a)(6)} <br />
The URL can be used to link to this page
Your browser does not support the video tag.