Laserfiche WebLink
Appendix S <br /> Health and Safety Plan <br /> Lustre-Cal Nameplate Corp. <br /> 6.0 AIR MONITORING <br /> The following air monitoring equipment will be used. <br /> X Photoionization Detector(PID) <br /> Flame Ionization Detector(FID) <br /> Draeger Pump and Tubes(specify tubes) <br /> Combustible Gas Meter(CGM) <br /> Oxygen Meter(02) <br /> X Dust(Particle)Meter(if dust is generated) <br /> Other(specify) <br /> The type and frequency of air monitoring for each work task is specified below. Air monitoring <br /> instruments will be calibrated and maintained according to manufacturer's specifications. Calibration <br /> information and air monitoring results will be recorded in project field notes. <br /> TASK INSTRUMENT FREQUENCY <br /> 1. Direct Push Drilling PID Every 15 minutes or as <br /> necessary <br /> 2. Hollow Stem Auger Drilling PID Every 15 minutes or as <br /> necessary <br /> 3. Mud Rotary Drilling PID Every 15 minutes or as <br /> necessary <br /> 4. Cone Penetrometer Testing PID Every 15 minutes or as <br /> (CPT) necessary <br /> 5. Groundwater Sampling <br /> (other than during drilling) <br /> 6. Soil Sampling (other than <br /> during drilling) <br /> 7. Excavation PID Every 15 minutes or as <br /> necessary, CGM when <br /> elevated concentrations are <br /> detected on the PID,Prior to <br /> proper entry to excavation <br /> Page 16 of 23 <br />