Laserfiche WebLink
Appendix S <br /> Health and Safety Plan <br /> Lustre-Cal Nameplate Corp. <br /> 6.1 ACTION LEVELS <br /> Cal/OSHA permissible exposure limits (PELs), American Conference of Governmental Industrial <br /> Hygienists (ACGIH) recommended threshold limit values (TLVs), and lower explosion limits (LELs) for <br /> the chemicals of concern at the Site are cited in the Table in Section 5.1 <br /> State of California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65) information <br /> for the Site: <br /> (Applicable warning is checked) <br /> ® WARNING: This area contains a chemical known to the State of California to cause <br /> cancer. <br /> WARNING: This area contains a chemical known to the State of California to cause <br /> birth defects or other reproductive harm. <br /> Respirators shall be worn when air monitoring indicates that concentrations exceed the following action <br /> levels: <br /> ■ Wear respirator if PID reads 5 ppm(sustained reading in the breathing zone) <br /> ■ Stop work if PID reads 25 ppm(sustained reading in the breathing zone) <br /> An explosion hazard shall be assumed to exist where air concentrations of the following chemicals exceed <br /> their respective lower explosion levels (LELs). <br /> ■ Stop work and notify the PM or PHSO if Combustible Gas Meter reads 10%LEL. <br /> ■ Evacuate area and notify appropriate emergency services if Combustible Gas Meter reads 25% <br /> LEL. <br /> age of ri <br />