My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008383
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
110
>
2900 - Site Mitigation Program
>
PR0009005
>
ARCHIVED REPORTS_XR0008383
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 12:01:06 PM
Creation date
5/11/2020 11:24:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008383
RECORD_ID
PR0009005
PE
2953
FACILITY_ID
FA0004053
FACILITY_NAME
LUSTRE-CAL NAME PLATE CO
STREET_NUMBER
110
Direction
E
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04124048
CURRENT_STATUS
01
SITE_LOCATION
110 E TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section i 1 <br /> ONSITE Environmental Laboratories, Inc Revision 0 <br /> ' Quality Assurance Plan Februan 15, 1996 <br /> Page 1 of 4 <br /> 11.0 OUT OF CONTROL EVENTS AND CORRECTIVE ACTIONS <br /> i <br /> Out of Control Events (conditions adverse to quality) are reported, documented and corrected <br /> at ONSITE Out of Control Events may arise from the failure of a process, human error, non- <br /> compliance with requirements, inadequate controls, or sample matrix problems Out of Control <br /> Events may include (but are not limited to) the following <br /> ' > Instrument failure <br /> ' > Sample holding time exceeded <br /> > Incorrect sample preparation or analysis techniques used <br /> ' > Calibration criteria not met <br /> > QC sample data (blank, spike, duplicate, surrogates, LCS) outside acceptance criteria <br /> ' > Data recording errors, transcription errors, calculation errors <br /> > Data verification errors <br /> > Any situation that might affect the final data quality <br /> 11 1 Roles and Responsibilities for Responding to an Out-of-Control Event <br /> ' When an out-of-control event is recognized, each individual involved with the analysis <br /> in question has an interactive role and responsibility <br /> 11 1 1 The Mobile Laboratory Chemist <br /> Must be able to recognize QC failure and immediately notify the supervisor <br /> ' and work with the supervisor and QA Director to solve the problem <br /> 11 1 2 The Mobile Laboratory Manager <br /> Must review all analytical and QC data for reasonableness, accuracy and <br /> clerical errors The Laboratory Manager must report the nonconformance to <br /> ' the Laboratory Director within 72 hours and works with the chemist and the <br /> Laboratory Director to solve the problem The Laboratory Manager prevents <br /> the reporting of suspect data by stopping work on the analysis in quesnon and <br /> insures that all results that are suspect are repeated, if possible, after the source <br /> of the error is determined and remedied <br /> Word 6 0 lodEsec 11 doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.