NOTES: UST INSTALLATION --- D mmah, <br /> TANK SLAB VARIES WITH - -- -_� <br /> OVERALL <br /> i NUMBER AND DIAMETER OF TANKS- - Specifications " „ RUN. <br /> f Tank Slab Concrete <br /> 2 O1 SLOPE CONCRETE AWAY FROM ALL MANHOLES 1 RISE OVER 12 <br /> I 3,-0" <br /> TYP.; \ .�\ <br /> FIBER REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> 2 CONCRETE. CONCRETE STRENGTH SHALL BE 4,000 PSI fc AT 28 DAYS, ':_:: »; :»<:_> <br /> UNLESS OTHERWISE NOTED ON THESE DRAWINGS: <br /> U MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS O HOWEVER THE MINIMUM DESIGN STRENGTH IS 2,500 PSI fc AT 28 DAYS. <br /> 1. a. CONCRETE — REGULAR WEIGHT HARD ROCK CONCRETE (150 LBS/CU FT) 5 THIS CONCRETE SPECIFICATION IS A VOLUNTARY UPGRADE, THERFORE <br /> O6 iv a- b. CEMENT — TYPE I/II, SULFATE RESISTANT AFTER PLACEMENT. <br /> NO SPECIAL INSPECTION OR TESTING IS REQUIRED. <br /> „ c. AGGREGATES - ASTM C33, (MAXIMUM SIZE 3/4 INCHES) <br /> / e 48 DIA. TURBINE 1 3 4 6, PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP REINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" GLOBAL FUELS TECHNOLOGY <br /> AND VENT STAGE II d. 28 DAY CONCRETE STRENGTH (f'c): 4,000 PSI - SLAB O 150 WARRENVIW: ROAD <br /> i MINIMUM DESIGN IS BASED ON 2,500 PSI. THIS IS A VOLUNTARY UPGRADE. THEREFORE NO CONCRETE UNLESS SPECIAL INSPECTION, IN ACCORDANCE WITH CHAPTER FROM SURFACE. NAPERVILLE, IWNOIS 60563-8473 <br /> VAPOR RECOVERY SPECIAL INSPECTION OR TESTING IS REQUIRED. 3 OF THE UBC, IS PROVIDED. REINFORCE CONCRETE SLAB AROUND MANHOLES WITH (4) #4 REBAR 60" <br /> SUMP (TYP.) e. SLUMP S 3"+ 1" - 4" MAXIMUM AT POINT OF PLACEMENTRESULTS, O IN LENGTH FOR LARGE MANHOLES 30" FOR SMALL MANHOLES. PLACE NATIONAL SITE ADAPT CONSULTANT: <br /> f. SHRINKAGE — 0.05% MAXIMUM 7, SUBMIT MIX DESIGNS, WITH STRENGTH AND SHRINKAGE TEST REBAR 6" FROM SIDES OF BOX. <br /> g. ENTRAINED AIR RANGE — 2% TO 4% TO OWNER'S ENGINEER AT LEAST 7 DAYS BEFORE PLACING CONCRETE. USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN <br /> i SAWED CONTROL JOINTS 78" & MAX OF 3/4" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. <br /> CONTROL JOINTS TO 2. CONCRETE SLAB THICKNESS SHALL BE A MINIMUM OF 7.0 INCHES UNLESS <br /> OTHERWISE NOTED 8. CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. O ALLD BS IITUTES UST BE APPROVED BY MANUFACTURER'S & OWNER'S <br /> BE "TOOLED" WITH FIELD <br /> 3 8" RADIUS ON THESE DRAWINGS. THICKEN EDGES AT MANHOLES AND SLAB ENDS. <br /> � 9. BEFORE PLACING CONCRETE, SECURE REINFORCING STEEL, ANCHOR BOLTS, TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br /> z <br /> 3. CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF 1 : 2 1/2 : 3 1/2, WITH A MAXIMUM 7 DOWELS, AND OTHER INSERTS IN POSITION TO PREVENT MOVEMENT. O COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR <br /> I - 1/2 GALLONS OF WATER PER SACK. ADD 1 .0 TO 1.5 LB STEALTH FIBER REINFORCING PER CU. PROPER TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING <br /> Y YD. CONCRETE. INTO TANK. ®t��®r Ryan ®nC. <br /> z 10, MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I. - 318 <br /> ~ I 4. REINFORCING STEEL - SUMP CAGES AT ALL OPENINGS SHALL BE #4 REBAR. (SPECIFICATIONS OF THE DESIGN AND PLACEMENT OF CONCRETE). O CORNERSNER WHEREERE MEETING ING CO CRETE. PAVING ONLY. SQUARE <br /> CUT 47 SIERRA CT. SUITE J <br /> 67 <br /> 7 <br /> 42" DIA. FILL & 1 3 4 DUBLIN, CA. 94568 <br /> o SEE SITE SPECIFIC PLANS FOR ACTUAL TANK SIZES, PLACEMENT, AND <br /> VAPOR VAPOR (925) 551-7555 <br /> ORIENTATION. FINAL SITE SPECIFIC TANK LAYOUTS SHALL BE APPROVED <br /> RECOVERY SUMP <br /> 8 <br /> BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL I <br /> (TYP-) LOCATION SIGN—OFF SHALL BE DOCUMENTED. MASTER DRAWING RELEASE HISTORY I <br /> z <br /> o VERSION <br /> TE <br /> 0 OXX V-0 MAY 000 X <br /> r w a� <br /> e ALTOMBELOWEGRADE SHALLBE <br /> 7 MIN. FIBER REINFORCED ` <br /> °� NOTES: CONCRETE SLAB. SEE Coxx v-1 FEB 2001 <br /> z OPENINGS IN SLAB TO HAVE 1-1/7_" LIQUID TIGHT AND LOCKABLE SPECIFICATIONS ABOVE. <br /> o CROWN (TMP ) 4 CONCRETE <br /> P.S.I. AB DESIGN Coxx V-2 JUNE 2001 <br /> TANK PA8 DAYS <br /> D SHALL EXTEND A MINIMUM COXX V-3 JAN 2002 <br /> 2'-0" BEYOND OUTSIDE WALLS OF 18" H <br /> 18" 18" COxX V-4 JUNE 2002 <br /> TANKS, AND MUST COVER THE ENTIRE A.C. PAVING 1-1/2" 18 1-1/2" (TMP ) (TYP.) A,C. Coxx V-5 FEB 003 0 <br /> FOOTPRINT OF THE TANKS. IN ORDER THICKENED (TYP. ALL) (TMP ) (TMP ) (TMP. ALL) <br /> TO PROVIDE FOR PROPER TANK HOLD PAVIi�IG Coxx v-o JULY 2004 <br /> CONCRETE EDGE _ L. - COXX V-7 MARCH 2006 <br /> DOWN, AND TO 'PREVENT ACCIDENTAL _ ^u <br /> Y w L <br /> z � � DRILLING INTO TANK. Z � u' _ _ �' Coxx V_6 JULY 2007 <br /> Q a Coxx V-8.1 DEC 2008 0l <br /> CHAMFER SLAB CORNERS WHERE • v w °— `- <br /> MEETING ASPHALT PAVING ONLY. o °•�o:o °.s;o ° ��$••0.° COXx v. s o JAN 2010 2 <br /> Q ° �` ... ............................... Vim° 3" PEA-GRA`✓EL MIN. TO <br /> SQUARE CORNERS WHERE MEETING 6 <br /> CONCRETE. 3" PEA-GRAVEL PREVENT LOAD TRANSFER 0 <br /> MIN. TO PREVENT TO TANK TOP 0 N <br /> o LOAD TRANSFER NO. DATE REVISION DESCRIPTION <br /> f TO TANK TOP 0- <br /> #4 <br /> #4 AROUND ALL o <br /> r f PENETRATIONS 2 <br /> I � \ 3 4 3 0 <br /> NOTE: <br /> 4 <br /> NOTE: CONTRACTOR IS REQUIRED TO THICKEN CONCRETE SLAB AT TANK FILL AND TURBINE s N <br /> ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW THE TOP OF THE TERMINATION <br /> O N CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. s o <br /> � OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB-2481 REQUIREMENTS. NOTE <br /> THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS ITEM THAT THE THICKNESS MAY VARY BETWEEN THE FILL AND TURBINE SUMPS AND IS ALSO E <br /> ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL BE DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL BE REQUIRED TO <br /> A <br /> PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE SLAB REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT a <br /> AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT MET. MET AS DETERMINED BY THE GOVERNING JURISDICTION. 9 a <br /> a <br /> 1'-0" CHAMFER 7" MIN. FIBER REINFORCED <br /> (TTP,) CONCRETE SLAB. SEE D <br /> 7 SPECIFICATIONS AT RIGHT. SECTION AT TANKS ! <br /> O sLAs En <br /> CONCRETE SLAB DESIGN A II : <br /> NIC SLAB REINFORCING 4 000 P.S.I. 0 28 DAYS SCALE: 1/2" = 1'-0" 0 <br /> TYPICAL TA , <br /> 2 0 <br /> NOT TO SCALE <br /> 3/8" EXPANSION JOINT SEAL- ° <br /> U <br /> JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY <br /> WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 1/4" RADIUS TOOL EDGE ��r1 a4, C� a <br /> PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" I INSTALL EXPANSION BOARD U' <br /> 3/8" EXPANSION JOINT OR EQUAL. 1-1/2" DEEP CAP SEAL (TYPICAL) <br /> "WESTEC ENVIROSTOP TPE-R" <br /> 1/4" RADIUS TOOL EDGE C. 1 c <br /> + � / OR EQUAL <br /> C <br /> � o �I E . 0 31111 * � <br /> PRODUCT SYMBOLOGY INSTALL EXPANSION BOARD a i o ° 3/8" EXPANSION JOINT ��y <br /> - JOINT SEALANT INSTALLATION IN PAVEMENT CAP SEAL (TYPICAL) g ° <br /> w lid MATERIAL SHALL COMPLY WITH SCF CAL��O U° <br /> SHALL COMPLY WITH ASTM C 920 TYPE M, "WESTEC ENVIROSTOP TPE-R" } � ASTM D1751. JOINT FILLER <br /> GRADE P, CLASS 25 PETROLEUM RESISTANT OR EQUAL <br /> Q W Q CAST IN PLACE v <br /> OPTION: SEALANT. USE "SEALTIGHT GARDOX" OR <br /> �� < d d 4 3 8" EXPANSION JOINT � � � � �, CONFI �Tlas6TY �TATEMENZ ~ <br /> PAINT API PRODUCT EQUAL. 1-1/2 DEEP / d <br /> MATERIAL SHALL COMPLY WITH d a THE REGPIE�:T OF THESE MATERIALS UNDERSTANDS THAT I <br /> CODE C 0 LO R 0 N LID a d <br /> COPYRIGHT IN THE MATERIALS IS CCOR BY BP, AND ALSO, <br /> ASTM D1 751. JOINT FILLER THAT THE MATER;AIS CONTAIN PRlYILEGED AND CONFIDENTIAL r <br /> 4 CAST I N PLACE �aI t� BUSINESS'AGREES T O OF 13P, ACCORDINGLY,THE N <br /> NE4'Y FIBER IRC iNFORCED CONFIDENCE <br /> E AND <br /> GR RETAIN THESE CLOSET M STRICT <br /> NEW FIBER REINFORCED r � [ (ONFlDENCE AND AGREES NOT TO DISCLOSE THESE <br /> I. SLAB ACCESS B C X C O I v C R�L�= NOT <br /> M TO ANY OTHER PARTY AND FURTHER AGREES <br /> RECIPIENT <br /> d CONCRETE I�` n :'=hTI0N5 NOT TO TO U E IHES A RI MATERIALS. THE LIMITED T <br /> I WITHOUT UT LID 0 ` I �— I D COLLAR LLAR P�I� �. C l (�4r AGREES TO AND THE MATERIALS ONLY RE THE UNITED � <br /> SHOWN � I PER SPECIFICATIONS PURPOSE FOR WHIG! 3P HAS MADE THE MATERIALS / <br /> AVAILABLE, AND REgPIENT AGREES TO RETURN ALL <br /> MATERIALS TO BP EITHER UPON COMPLETION OF THE C <br /> NEW FIBER REINFORCED INTENDED PURPOSE OR UPON THE REQUEST OF BP, <br /> WHICHEVER COMES FIRST. � <br /> f EXPANSION CONSTRUCTION <br /> JOINT AT DISPENSER ISLAND (TYPICAL). CONCRETE EXPANSION CONSTRUCTION JOINT AT NEW PAVEMENT (TYPICAL). <br /> PIPE AND <br /> PER SPECIFICATIONS NOT TO SCALE BP DOES NOT AND CANNOT WARRANT THAT THE PLANS FOR / <br /> NOT TO SCALE PETROLEUM STORAGE AND DISPENSING ARE COMPLIANT BE N <br /> SYMBOL L C 0 LO R S ALL LEGAL REQUIREMENTS THAT DOES <br /> OR AS THEY MAY BE C <br /> TEXT SY" APPLIED IN THE FUTURE.DELIVERY <br /> DOES BP WARRANT THAT A C <br /> FUELING STORAGE AND DE]J4ERY SYSTEM CONSTRUCTED IN •3 <br /> I. „ CONFORMITY WITH THESE PLANS WILL BE FREE OF ALL C <br /> 3 [� JOINT LEAKS YOU ARE ACCORDINGLY STRONGLY ENCOURAGED TO L <br /> JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY CONSULT WITH A FUELING STATION ENGINEER OF YOUR <br /> WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 CHOOSING TO INDEPENDENTLY EVALUATE WHETHER THESE <br /> 1 4" RADIUS TOOL EDGE PLANS ARE TRULY SUFFI SYSTEM <br /> FOR CONSTRUCTING THE / <br /> PREMIUM UNLEADED S ON RED CIRCLE PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" / STORAGE AND DELIVERYINFOYSTEM AT YOUR STATION. C <br /> GASOLINE WHITE CROS 6" ACCESS PORT <br /> ° OR EQUAL. 1-1/2" DEEP DEVELOPMENT INFORMATION: E <br /> -- INSTALL EXPANSION BOARD <br /> FILL PORT EXISTING PAVEMENT <br /> NEW PAVEMENT ___ __________________ __ CAP SEAL (TYPICAL) UNDERGROUND STORAGE o <br /> STAGE I VAPOR c� "WESTEC ENVIROSTOP TPE-R" <br /> MID—GRADE UNLEADED OSS ON BLUE CIRCLE RECOVERY a TANK STANDARDS <br /> GASOLINE WHITE CR OR EQUAL <br /> GA ° I ° ELEMENT TPO1 Cn <br /> ° w g °. 3/8" EXPANSION JOINT <br /> / V-9.0 2010 SERIES ,. <br /> ` <br /> ASTM D1751. JOINTFILLER <br /> WITH CALIFORNIA MARKET ry <br /> REGULAR UNLEADED LACK CROSS ON WHITE CIRCLELd <br /> GASOLINE ° a ' CAST IN PLACE LID <br /> o <br /> `, o <br /> THIS AREA TO ° d I SITE ADDRESS: <br /> d DRILL EXISTING CONCRETE o <br /> FOR DOWEL PLACEMENT O <br /> AUTO YELLOW HEXAGON grey or white _ <br /> DIESEL n / <br /> 3/4" DIA. X 18" L. GREASED STEEL o <br /> ¢ 4x4 HIGHWAY 00 <br /> `( ORANGE CIRCLE STAGE I VAPOR RECOVERY <br /> REFLECTOR MARKER DOWEL CSD 18" O.C. <br /> VAPOR RECOVER ---- FOR PRODUCT Lu <br /> FILL PORT ° IDENTIFICATION. <br /> COLORED PER API EXPANSION JOINT AT NEW AND EXISTING PAVEMENT (TYPICAL) Q <br /> I STANDARDS. EPDXY DESIG'M BY: SHK/o ALLIANCE Z&W* DB v) <br /> NOT TO SCALE <br /> ON WHITE FIELD B� CONTRACTOR <br /> BLACK TRIANGLE CHEM eY: SHK/o BP RPM: DB o <br /> E OBSERVATION WELL JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY ALLIANCE J <br /> I WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 ' BY: GRS/® ' DB uJ <br /> PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" SAWED JOINT 1�� X 2 DEPTH WITH , PRO ECT Na � <br /> �I��OL� OR EQUAL. 2" DEEP FLARED EDGE EASER ���'® <br /> -.1 <br /> REF: API 1637 PRODUCTS 01/04/2010 0 <br /> d DRAWING TITLE: a <br /> NOTE: THE ABOVE SYMBOLS REPRESENT INDUSTRY 1 - a a <br /> TANK SLAB <br /> GUIDELINES FOR PRODUCT IDENTIFICATION. CONSULT THIS AREA TO grey or white z a N d ° d�IDENTIFICATIONINARKINGDETAILS � <br /> U) g <br /> LOCAL DISTRIBUTION MANAGER FOR LOCAL METHOD ° <br /> OF PRODUCT IDENTIFICATION TO BE USED. 8" ACCESS PORT TO BEOf <br /> ORIENTATED TO THE SAME SIDE Q <br /> �a d 4 a / <br /> AS TANK LEVEL GAUGE SHEETNO: <br /> a a <br /> API STANDARD COLORS <br /> a <br /> I UNLEADED PREMIUM - RED o <br /> REGULAR UNLEADED - WHITE <br /> I UNLEADED PLUS - BLUE mm5,3,2�1 w1 <br /> ACCESS COVER IDENTIFICATION AUTO DIESEL - YELLOW <br /> ILL / <br /> STANDARD TWO POINT F CONTROL JOINT (SAWED) XX NOTE: INDICATES ITEMS FOUND ON <br /> I DAPI COLOR AND IDENTIFICATION SYMBOLS SCALE: 1/2" = 1'-0" NOT TO SCALE MATERIALS LIST SHEET M.5.3.01 & M.5.3.02 <br /> STANDAR <br /> SCALE: NONE <br /> i <br />