Laserfiche WebLink
File No. 20-3978-0LP02 K L E IN FELD E R <br /> November 5, 1996 <br /> B-2.7 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are <br /> steam cleaned prior to drilling each boring. In addition, sampling equipment is cleaned <br /> with a trisodium phosphate or non-phosphate detergent wash and rinsed with distilled <br /> water prior to collecting each soil sample. <br /> B-2.8 Soil Boring Closure and Cutting Disposal <br /> Soil borings are closed immediately after the collection and logging of soil samples. <br /> Closure is accomplished by grouting the boring with a cement(bentonite slung or as <br /> otherwise required. <br /> Drill cuttings will be placed in 55-gallon drums wrapped in plastic or spread around the <br /> boring and left on site for disposal by the site owner. If requested, Kleinfelder can <br /> coordinate disposal of soil and water after analytical results are available. <br /> B-3 GROUNDWATER WELL INSTALLATION <br /> B-3.1 Monitoring Well Construction <br /> Construction details for shallow groundwater monitoring wells are as follows: <br /> • The well casing are 2- or 4-inch inside diameter, flush threaded joint, schedule 40 <br /> PVC pipe. <br /> • The wells are constructed in 8- or 10-inch diameter borings. <br /> • Well screen sections are perforated with 0.010- or 0.020-inch factory-cut slots. <br /> • The wells are generally screened from 5 feet above to 15 feet below first <br /> groundwater. The screen length is reduced if an aquitard with a minimum <br /> thickness of 5 feet is encountered. If an apparent aquitard is encountered, the well <br /> is usually terminated 1 to 2 feet into the aquitard. Effort is made not to screen <br /> across two aquifers. If confined aquifer conditions or high vadose zone <br /> contamination are encountered, the well screen is usually not set above the depth <br /> of first encountered groundwater. Wells are usually not set in areas of suspected <br /> significant soil contamination. <br /> • The PVC pipe and end caps are steam cleaned prior to installation. <br /> 20-3978-01.P02IMP960129 Page B-4 01996, Kleinfelder, Inc. <br />