Laserfiche WebLink
SAN J 0 A Q U 1 N Environmental Health Department <br /> U ; i y 1 Iii <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GARDNER TRUCKING INC 2577 W YOSEMITE AVE, MANTECA September 23, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATIONS: Inspections of the hazardous waste tank system was not performed and documented. <br /> REGULATORY GUIDANCE: The following items are required to be inspected at least daily: <br /> 1. overfill/spill control equipment; <br /> 2. aboveground portions of the tank system to detect corrosion or releases of water; <br /> 3. data gathered from monitoring and leak-detection equipment; <br /> 4. outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br /> hazardous waste; <br /> 5.for uncovered tanks, the level of waste in the tank. <br /> CORRECTIVE ACTION: Immediately begin required inspections of the hazardous waste tank system, and <br /> document the items inspected. Submit a copy of the inspection log for the next 30 days to the EHD. <br /> This is a Class II violation. <br /> 512 CCR 66265.192(h) Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br /> OBSERVATION: This facility has hazardous waste tanks which have not been reassessed by a Professional <br /> Engineer within the past five years. <br /> -One approximately 400 gallon used oil tank observed with no tank assessment performed in the last 5 years. <br /> Note: Shop manager is new to the facility and cannot locate the most recent tank assessment test. <br /> REGULATION GUIDANCE: <br /> The assessment specified in subsection (k)of this section shall be obtained prior to placing a new tank system in <br /> service and shall be kept on file at the facility.This assessment shall be reviewed and certified by an independent, <br /> qualified, professional engineer, registered in California, in accordance with section 66270.11(d), attesting that the <br /> tank system has sufficient structural integrity and is acceptable for the transferring, storing and treating of hazardous <br /> waste. The assessment shall be valid for a maximum period of five(5)years or the remaining service life of the tank <br /> system, as stated in the engineer's assessment,whichever is less. <br /> CORRECTIVE ACTION: Provide a corrective action statement and supporting documentation to the San Joaquin <br /> County Environmental Health Department(EHD)within 30 days. Provide a complete copy of the tank assessment <br /> document,when available. <br /> This is a Class II violation. <br /> FA0010976 PR0517960 SCO01 09/23/2019 <br /> EHD 22-02 Rev.9/20/2019 Page 10 of 11 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />