Laserfiche WebLink
Kennedy/Jenks Consultants <br /> • <br /> ' Kennedy/Jenks to confirm that correct sampling analyses were being performed and that all <br /> samples specified in the SAP were collected. <br /> In addition, data verification and validation were conducted to assess the laboratory's <br /> performance in meeting the quality objectives identified in the QAPP (e.g., reporting limits and <br /> control limits) and performance-based criteria specified in the analytical methods. QA objectives <br /> ' for measurement data were provided by STL and are listed in Appendix D. Data validation was <br /> performed by the Kennedy/Jenks' project staff. <br /> 4.3 Laboratory QA/QC <br /> All analyses were performed consistent with STL's quality assurance program. When applicable <br /> ' to the test method, method blank results have been reported with each analytical test. Surrogate <br /> recoveries have been reported for all applicable analyses. Other quality control analyses <br /> performed include Laboratory Control Spike/Laboratory Control Spike Duplicate (LCS/LCSD); <br /> Matrix Spike/Matrix Spike Duplicate (MS/MSD); Relative Percent Difference (RPD); and <br /> ' laboratory blank tests. <br /> The quality control data was reviewed against data validation parameters (control limits) <br /> ' provided by STL. The data was found to be fully usable. The following is a list of the exceptions <br /> to the data validation parameters as summarized in Tables 3 and 4: <br /> Surrogate recoveries were outside control limits due to matrix interference. Some of the <br /> surrogate recoveries were not obtained because the extract was diluted for analysis due to <br /> highly concentrated samples (these compounds were flagged with a "D"). <br /> Matrix spike and matrix spike duplicate recoveries were outside acceptable limits. Some of <br /> the matrix spike recoveries were not obtained because the extract was diluted. Some of the <br /> ' analytes present in the original sample in the MS/MSD were four times greater than the <br /> matrix spike concentrations. In these instances, the control limits were not applicable. <br /> • Some of the RPD values were outside the acceptable limits. <br /> • Some of the sample quantities were insufficient to perform matrix spike and matrix spike <br /> duplicate. Consequently, the LCS was performed in duplicate for QC purposes. <br /> • The upper control criterion was exceeded in some analytes. The errors associated with the <br /> elevated recoveries equate to a high bias; therefore, sample data has not been significantly <br /> affected. <br /> Despite some of these exceptions to the data validation parameters, the sample datum has not <br /> ' been significantly affected and no corrective action was necessary. <br /> • <br /> DRAFT Phase I Remedial Investigation Report Page 21 <br /> ' Former Tracy Railyard, Tracy, California <br /> g:Vs-groupladmin\job105\0565777.18_uprr109-reports\ri rpt%text.doc <br />