• sod sampling at desired intervals Sod samples are collected analysis(VOA)vials,wrth'Tefon"septa are used as sample <br /> by either hammering(with a 140-pound drop hammer)or containers <br /> hydraulically pushing a conventional split-barrel sampler <br /> containing pro-cleaned 2-inch-diameter brass tubes A The groundwater sample is decanted into each VOA vial in <br /> geologist or engineer from Apex Enmrotech,Inc,continuously such a manner that there is no meniscus at the top of the Hal <br /> logs each borehole during dnlAng and constantly checks drill A cap is quickly secured to the top of the Hat The vial is then <br /> cuttings for indications of both the first recognizable inverted and gently tapped to see it air bubbles are present If <br /> occurrence of groundwater and volatile hydrocarbons using none are present,the mal is labeled and refrigerated for <br /> either a portable photownization detector,flame ionization delivery,under strict chain-of-custody to the analytical <br /> detector or an explosimeter The sampler is rinsed between laboratory Label information should include a unique sample <br /> samples and either steam cleaned or washed with all other identification number,lob identification number,date,time,type <br /> drilling equipment between borings to minimize the potential for of analysis requested,and the sampler's name <br /> cross-contamination <br /> For quality control purposes a duplicate water sample is <br /> Monitoring wells are cased with threaded,factory-perforated collected from each well This sample may also be analyzed or <br /> and blank Schedule 40 PVC The perforated interval consists put on hold at the laboratory When required,a trip blank, <br /> of slotted casing,generally with 0 020-inch wide by 1 cinch prepared at the laboratory is placed in the transport cooler It <br /> long slots,with 42 slots per foot A PVC cap may be secured is labeled similar to the well samples remains in the cooler <br /> to the bottom of the casing with stainless steel screws no during transport,and is analyzed by the laboratory along with <br /> solvents or cements are used Centering devices may be the groundwater samples In addition afield blank may be <br /> fastened to the casing to ensure even distribution of filter prepared in the field when sampling equipment Is not <br /> material and grout within the borehole annulus The well dedicated The field blank is prepared after a pump or baiter <br /> casing is thoroughly washed and/or steam cleaned,or may be has been either steam cleaned or properly washed,prior to use <br /> purchased as pre-cleaned,prior to installation in the next well and is analyzed along with the other samples <br /> The field blank analysis demonstrates the effectiveness of the <br /> After setting the casing inside the hollow-stem auger,sand or in-field cleaning procedures to prevent cross-contamination <br /> gravel filter material is poured into the annular space to fill from <br /> boring bottom to generally 1 foot above the perforated interval To minimize the potential for cross-contamination between <br /> A 1-to 2-foot thick bentonte plug is set above this filter material wells,all well development and water sampling equipment not <br /> to prevent grout from infiltrating the filter pack. Ether neat dedicated to a well is either steam cleaned or properly washed <br /> cement containing about 5 percent bentonte,or sand-cement between use Asa secondaryprecautionary measure,wells <br /> grout is then tremmied into the annular space from the top of are sampled in order of least to highest concentrations as <br /> the bentonte plug to near surface A traffic-rated vault is established by available previous analytical data <br /> , . Installed around each wellhead for wells located in parking lots <br /> or driveways,while steel"stovepipes"are usually set over in the event the water samples cannot be submitted to the <br /> wellheads in landscaped areas analytical laboratory on the same day they are collected(e g <br /> due to weekends or holidays) the samples are temporarily <br /> After installation,the yells are thoroughly developed to remove stored until the first opportunity for submittal either on water ice <br /> residual drilling materials from the wellbore,and to improve well in a cooler such as when in the field or in refrigerator at <br /> performance by removing fine material from the filter pack that Apex s office <br /> may pass into the well Well development techniques used <br /> may include pumping,surging,bailing swabbing letting, $Op _ 10 <br /> flushing and air-lifting All development water is collected MEASURING LIQUID LEVELS USING <br /> either in drums or tanks for temporary storage,and properly WATER LEVEL METER OR INTERFACE <br /> disposed of depending on laboratory analytical results To PRO BE <br /> minimize the potential for cross-contamination between wells, <br /> all development equipment is ether steam cleaned or properly Field equipment used for liquid level gauging typically includes <br /> washed prior to use Following development the well is the measuring instrument(water-level meter or interface probe) <br /> allowed to stand undisturbed for a minimum of 24 hours before and product boiler(s) The field kit also includes cleaning <br /> As first sampling supplies(buckets solution spray bottles and deionized water) <br /> SOP - 7 to be used in cleaning the equipment between wells <br /> GROUNDWATER PURGING AND Prior to measurement the instrument tip is lowered into the well <br /> SAMPLING until 9 touches bottom Using the previously established top-of- <br /> casing or top-of-box(i e,wellhead vault)point,the probe cord <br /> Prior to water sampling each well is purged by evacuating a (or halyard)is marked and a measuring tape(graduated in <br /> minimum of three wetted well-casing volumes of groundwater hundredths of a foot)is used to determine the distance <br /> When required,purging will continue until ether the discharge between the probe end and the marking on the cord This <br /> water temperature,conductivity,or PH stabilize,a maximum of measurement is then recorded on the liquid-level data sheet as <br /> ten weded-casing volumes of groundwater have been the"Measured Total Depth"of the well <br /> recovered or the welt is bailed dry When practical,the <br /> groundwater sample should be collected when the water level When necessary in using the interface probe to measure liquid <br /> in the well recovers to at least 80 percent of is static level levels,the probe is first electrically grounded to ether the metal <br /> stove pipe or another metal object nearby When no ground is <br /> The sampling equipment consists of either a'Teflon"bailer available,reproducible measurements can be obtained by <br /> PVC bailer,or stainless steel bladder pump with a'Teflon" clipping the ground lead to the handle of the interface probe <br /> bladder If the sampling system is dedicated to the well,then case <br /> the baiter is usually'Teflon,"but the bladder pump is PVC with <br /> a polypropylene bladder In general and depending on the <br /> intended laboratory analysis,40-milliliter glass,volatile organic <br /> SOP- Mondonng Wells <br />