As shown in Figure 6, the vapor influent contaminant concentrations, for the reporting period <br /> between March I0 and July 16, 2003, were on a steady decreasing trend from March through May <br /> In lune (coincident with the start of the 300 SCFM blower system)the vapor influent concentrations <br /> increased to concentrations observed at the beginning of the reporting period The mass removal <br /> trend (Figure 7) demonstrates that mass removal is on a steady low angle incline <br /> ' 3 3 2 Ozone Sparging System <br /> An ozone generator, enclosed in a wooden shed, injects ozone into groundwater in 19 ozone sparge <br /> ' wells (S-1 through S-19) located onsite and offsite Sparge well S-20 was not mamfolded to the <br /> system and is not used as a sparge well An ozone meter installed in the shed will shut down the <br />' iemediation system if the sensor detects ozone levels greater than 0 01 ppm within the shed The <br /> ozone injection manifold is set up to inject ozone for 10 minutes at a time into the sparge wells It <br /> can cycle through 10 wells at 100%the maximum injection rate, or all 20 wells (two wells at a time) <br />' at 50% the maximum injection rate Approximately 2 5 pounds of ozone (total for all wells) is <br /> injected into the subsurface each day The ozone sparge system delivers at a rate of 6 cfm <br /> jAfter system startup on November 26, 2002, several ozone leaks were detected at the injection <br /> manifold and were repaired O&M was performed weekly to record ozone sparge operational data <br />' such as ozone concentrations, hours of operation, and to check leaks at the ozone injection manifold <br /> and ozone sparge wellheads During the fourth quarter of 2002, ozone was not detected around any <br /> ozone sparge well boxes Ozone was detected in the shed housing at a maximum concentration of <br /> 0 41 ppm (December 4, 2002) The source of the leak was found and repaired No leaks have been <br /> detected since December 2002 The O&M schedule for the ozone sparge system is monthly <br /> In response to the Second Quarter groundwater analytical data, the open/closed status of the sparge <br />' wells was reconfigured on April 22, 2003 Each sparge well that was within the influence of the <br /> gioulidwater plume was placed in the open position,those outside of the plume were closed Oil May <br /> 27, 2003, it was observed that there was no flow registering on the ozone generator flow meter <br /> Moisture was observed in the ozone line leading from the ozone generator to the sparge pump It was <br /> also observed that the pressure relief valve in the oxygen condenser was relieving frequently <br />' Geocon consulted with ARCE Systems, Inc , the manufacturer of the ozone system, to correct the <br /> system ARCS indicated that the ozone generator would need maintenance that could only be <br /> performed at their shop and the oxygen condenser would have to be re-packed by the manufacturer <br /> On May 30, 2003, the ozone generator and oxygen condenser were removed and transported to <br /> ARCS in Massachusetts The re-furbished equipment is scheduled to go back on line the week of <br /> July 28, 2003 Historical operational data including well open/closed status, ozone leak detection <br /> monitoring data, and presence of an odor are presented in Table 8 <br /> SE643-00-01 -7- July 25 2003 <br />