My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013298
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
5218
>
2600 - Land Use Program
>
SU-87-14
>
SU0013298
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2020 1:51:16 PM
Creation date
5/19/2020 10:55:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013298
PE
2600
FACILITY_NAME
SU-87-14
STREET_NUMBER
5218
Direction
E
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95212-
APN
08607013
ENTERED_DATE
5/18/2020 12:00:00 AM
SITE_LOCATION
5218 E EIGHT MILE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
361
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J. H. KLEINFELDER & ASSOCIATE_S <br /> File No. S-2314-1 <br /> August 15, 1978 <br /> PAGE TWELVE <br /> Pavement Sections <br /> We performed Resistance-Value Tests on samples of the <br /> surface soil at this site. These test results indicate <br /> T <br /> R-Values of 20 and 21 at an exudation pressure of 300 pounds <br /> per square inch. We have used a Resistance-Value of 15 as <br /> a design value to account for possible soil and compaction <br /> variations in the field. Based on this design R-Value. and on <br /> an assumed Traffic Index of 5 for interior residential streets , . <br /> we recommend the following pavement sections : <br /> Recommended Recommended <br /> -. Recommended Thickness of Thickness of <br /> Thickness of Class II Class III <br /> Asphalt Concrete Aggregate Base ASB <br /> 2 4 7 <br /> 3 8 - <br /> Based on recent studies by our firm, it may be possible <br /> to increase the design R-Value to 50 by the addition of approxi- <br /> mately 3 to 4 percent lime to the subgrade soils . For this <br /> design value, a pavement section of 2 inches of asphalt concrete <br /> underlain by 4 inches of aggregate base would be required for a <br /> Traffic Index of 5 . Our firm can provide additional information <br /> if this alternative is to be considered further. <br /> The subgrade soils over which these paving materials <br /> are placed should be compacted to a minimum depth of 12 inches <br /> to a minimum 95 percent of ASTM D-1557-70 maximum dry density. <br /> In addition, it is recommended that all pavements conform <br /> to the following criteria : <br /> 1 . All trench backfills, including utilities <br /> and sprinkler lines should be properly <br /> placed and adequately compacted to provide <br /> a stable subgrade. <br /> 2. An adequate drainage system should be <br /> provided to prevent surface water or <br /> subsurface seepage from saturating the <br /> subgrade soil . <br />
The URL can be used to link to this page
Your browser does not support the video tag.