Laserfiche WebLink
i <br /> StPt7 9 - Tank Changes <br /> This is the last step in the decontamination procedure <br /> for those workers wishing to change air tanks and <br /> return to the exclusion zone . The worker' s air tank is <br /> exchanged , new outer glove and boot covers are donned , <br /> and the joints are taped . <br /> Needed Equipment : Air tanks , tape , boot covers , and <br /> Step 10 - Removal of Safety Boots <br /> Remove safety boots and deposit in container with a <br /> plastic liner. <br /> Needed Equipment: Container ( thirty to fifty gallons) , <br /> plastic liners, boot jacket, and bench or stool. <br /> Step 11 - SCBA Backpack Removal <br /> Without removing face piece , the SCBA backpack should <br /> be removed and placed on a table . The face piece <br /> should then be disconnected from the remaining SCBA <br /> unit and the personnel should then proceed to the next <br /> Step. <br /> Needed Equipment: Table <br /> Step 12 - Splash Suit Removal <br /> With care , remove splash suit . The exterior of the <br /> splash suit should not come in contact with any inner <br /> layers of clothing. <br /> Needed Equipment: Container .( thirty to fifty gallons) , <br /> plastic liners, and bench or stool . <br /> Step 13 - Inner Glove Wash <br /> The inner gloves should be washed with a mild decontam- <br /> ination solution (detergent/water) . <br /> Needed Equipment : Decontamination solution (deter- <br /> gent/water solution) , basin or bucket, and table. <br />