My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 4:44:13 PM
Creation date
5/19/2020 3:40:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST INSTRUCTIONS Socket PREVENTIVE MAINTENANCE Good Valve <br /> POPPET&FLOAT MOVEMENT Annually,Inspect the flapper In the 71 SO to see that R is <br /> adaptor •Deflection Shield <br /> FOR TESTABLE MODELS ONLY _ open by looking down the drop tube opening(see in- <br /> - opp <br /> spection procedure below).Test the 71 SO drop tube `'td' .d <br /> TOOLS NEEDED FOR TESTING: sealswfth CARS procedure TP-201.1D.Irccted <br /> fthedroptube ( pro <br /> 1. 1/4'squaredrive extension or 3/8"square drive ex- seal passes testing,no further maintenance Is required. <br /> tension with 3/8'to 1/4"socket adapter. a If the drop tube falls testing,replace the drop tube seal <br /> 2. Torque wrench/1/4'or 3/8"square drive ratchet with DPW P/N:H11931M for 4"Tubes.Re-test the 71 SO <br /> wrench. drop tube with CARS procedure TP-201.1 D.The lower <br /> 3. Pipe dope. tube o-ring seal DPW PM:HI 4840M can also be <br /> 4. Fl ashlight(optional). placed.If this does not correct the leak the 71 SO needs <br /> Open Poppet Closed Poppet to be replaced. <br /> TEST STEP 1: Bad Valve <br /> Remove spill container covet and fill cap from fill adapt- Test Figure 1 FOR TESTABLE MODELS ONLY:The socket adaptor Defleedon Shield <br /> er and look down Into the tube and make sure no debris Pull on extension and can be removed and poppet and float movement and 'mioh Popp.,exposed <br /> or foreign objects are present.If debris or foreign ob- socket adaptor function Inspected without removing the valve.See ' <br /> jests are present take appropriate steps before proceed- Page 17 for full testing details.If replacement parts are <br /> Ing.Look down into the tube and ensure poppet is +"'- needed for testable models the following hems are <br /> completely protected by the deflection shield.SeeTest awilable:DPW P/N 206741 Testable Inlet Tube S/A, <br /> Figure 1.If poppet Is exposed and tank Is not full the i' 206740 Socket Adaptor and Cade Assembly,and 61 SOK <br /> overfill valve should be replaced.A flashlight may help ! -0001 Float lat. <br /> wheninspecting the tube. I Figure 27 <br /> CAUTION:Do not insert any foreign object into drop F .1 <br /> TEST STEP 2: tube ifflapper is In the closed position.Forexam- Note.Figure 27 shows poppet location with float arm <br /> Unthread the socket adaptor assembly from the inlet _ ple,a tank level measuring stick.This will damage notactivated. <br /> tube usinga l/4'square drive extension and wrench. I the valve and void the Warranty.ALWAYS check <br /> The extension will attach to the socket adaptor.Secure flap per location before"sticking'the tank.Ifflap- INSP4.Inspect the float by lifting upward.The float <br /> all tools to ensure they don't fall Into the tank or valve. per is in the closed position,the tank is either over- should move freely without any binding.See Figure <br /> With the extension still attached pull on the socket --.— filled and you need to wait until the liquid level goes 28. <br /> adaptor and cable assemblyand ensure float and pop- —-------- down or the 7150isdamaged and needs tobe re- <br /> pet move <br /> /function properly.It should only require 3' L placed. - <br /> toV of movement and less than 5 Its of force In order """ <br /> to actuate the float and poppet.When looking down - Inspection Procedure to Ensure Proper Operation _ <br /> Into the upper tube ensure poppet is visible and moves Note:For testable models valve does not need to be <br /> into the flow path(see Test Figure 1&2)when socket Open removed from tank See page 17 for testable Instruc- <br /> ada for is pulled and resets properly p- Poppet Closed <br /> p p p perly when socket I tions. _ <br /> for is released.if poppet does not actuate freely take Poppet Floatmoves INSP 1.Remove the overfill valve from the tank as de- - <br /> appropriate steps to correct. up scribed In step 26. ' <br /> TEST STEP 3: -' INSP 2.Visually Inspect the valve for damage.Make <br /> Apply pipe dope to the socket adaptor threads.Pipe sure no debris or foreign objects are In or on the valve. <br /> dope should be a non-hardening gasoline resistant pipe INSP 3.With the float in the normal(down)position, <br /> thread seal compound.Make sure poppet and float I visually inspect the valve to ensure the poppet is not Figure 28 <br /> have reset properly and are not visible then Install sock- exposed outside the deflection shield.See Figure 27. <br /> etadaptor and torque to 35 ft-lbs(42 In-lbs)minimum I I INSP S.View down the tube to ensure the poppet is <br /> to 5.0 ft-lbs(60ln-lbs)maximum.After Installing socket moving into the flow path when lifting the float.See <br /> adaptor,to ensure vapor tightness,DPW recommends Figure 29. <br /> conducting pressure testing per CARS TP201.1 D.Some TestFigure2 <br /> areas may require pressure testing of overfill valve per <br /> CARS TP201.1 D to ensure valve Is vapor tight.If the <br /> drop tube falls pressure testing It may be necessary to <br /> check the seal at the poppet adaptor threads.Reinstall <br /> fill cap and spill container cover after testing. <br /> 17 18 <br /> Auoendix A <br /> bsed 7150 Overfill Valve Upper Tube Calculation Worksheet <br /> Important:This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions.All length measurements are in inches.Please contact the Authority Having Jurisdic- <br /> tion(AHJ)and review local,state,and national codes to determine the regulatory requirements governing <br /> fr s. <br /> shut-of opacity in your region,as well as take into account other considerations such as extreme tanktilt. <br /> Desired tank capacityfor shutoff. 50%= <br /> Dipstick Number on Tank Chart that corresponds to 100%volume(Y)- 0 Y <br /> Figure29 Dipstick Number on Tank Chart that corresponds to 50%(X) — E�M <br /> Upper Tube Reference Number Z=Y-X 0 <br /> INSP all6.theIf valereve <br /> is no apparentabove <br /> I mage ionsor and Less — <br /> reinstall the valve per the above Instructions and test Upper Tube Depth Inside Tank C=Z-2' <br /> (C) <br /> per local requirements. Distance from top sealing surface for 71 SO Llp'to Inside the O <br /> top of Storage Tank' A. <br /> 7150 Performance Specifications <br /> This Overfill Prevention Valve has been manufactured <br /> and tested to,and met,the following California specifi- <br /> cations.Performance Requirement-.Leak rate to be less In all cases for non-testable 7150 models,the top of the valve body must protrude at least 6'%'into the tank to <br /> than or equal to 0.17 CFH@2.W W.C. provide a minimal clearance for proper operation'Additionally the total Upper Tube Length must beat least 16" <br /> Specification Torque S of length to Include the protective bend in the tube. <br /> q <br /> Taptite Screws#10-24 thread cutting,201n-lbs mini- Is C less than 6l5' Yes/ No <br /> mum to 35 In-lbs maximum.Testable Models Only: <br /> Socket Adaptor,1/4'NPT,35 ft-lbs(42 in-lbs)minimum <br /> to 5.0 ft-lbs(601n-lbs)maximum. If NO,Upper Tube Length(Dj=C+A <br /> If YES,Upper Tube Length(0)=6%"+A <br /> IMPORTANT:Leave these installation instructions <br /> and maintenance procedures with the station opera- Upper Tuba Length= <br /> tor. <br /> For Testable 71 SO models only <br /> In all cases for Testable 7150 models,the top of the valve body must protrude at least 6%-Into the tank to provide <br /> aminimal clearance for proper operation?Additionally the total Upper Tube Length must beat least 14%'of <br /> length to Include the protective bend In the tube. <br /> Is C less than 5' Yes/ No <br /> If NO,Upper Tube Length(D)=C+A-1 Yz' <br /> If YES,Upper Tube Length(0)=6%'+A-1'ft' <br /> Upper Tube Length= <br /> ' Sealing surface maybe the top ofthe FamSea/Adapmc thebullfinseallgkdge insbesomespilJcontainmoronnon- <br /> vapor tight applicatrons the top ofthe pipe nipple <br /> ' Some UndergroundSrorage tanksud/bes manwaysorem at the top.AOkestoe to use the top ofthesroage tankfor <br /> measurementandnottotopofthemunway.C nsubyrourundergrourdtankmanufarturerforheightofthemanway <br /> ' This measummentis takenfrom theseam where the uppertube/sadachedto the wlwbadyto the Inside ofthe tank top <br /> 19 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.